Name | Description | Default | Type |
---|---|---|---|
{$HD_TEMPERATURE_ALARM} | <p>-</p> | 51 |
Text macro |
{$HD_TEMPERATURE_WARNING} | <p>-</p> | 45 |
Text macro |
There are no template links in this template.
Name | Description | Type | Key and additional info |
---|---|---|---|
System fans discovery | <p>-</p> | SNMP agent |
sysFans.discovery<p>Update: 3600</p> |
Network interfaces discovery | <p>-</p> | SNMP agent |
netIfs.discovery<p>Update: 3600</p> |
Volumes discovery | <p>-</p> | SNMP agent |
sysVolumes.discovery<p>Update: 3600</p> |
Hard disks discovery | <p>-</p> | SNMP agent |
sysHDs.discovery<p>Update: 3600</p> |
Name | Description | Type | Key and additional info |
---|---|---|---|
System uptime | <p>-</p> | SNMP agent |
system.uptime[sysUpTime]<p>Update: 30s</p> |
Device hardware revision | <p>-</p> | SNMP agent |
PhysicalHardwareRev<p>Update: 10800</p> |
Device vendor name | <p>-</p> | SNMP agent |
sysPhysicalMfgName<p>Update: 3600</p> |
Device software revision | <p>-</p> | SNMP agent |
PhysicalSoftwareRev<p>Update: 3600</p> |
CPU temperature | <p>CPU temperature in centigrade</p> | SNMP agent |
CPU-TemperatureEX<p>Update: 60</p> |
System free memory | <p>-</p> | SNMP agent |
SystemFreeMemEX<p>Update: 60</p> |
System free memory (%) | <p>-</p> | Calculated |
SystemPFreeMemEX<p>Update: 60</p> |
System temperature | <p>System temperature in centigrade</p> | SNMP agent |
SystemTemperatureEX<p>Update: 60</p> |
System total memory | <p>-</p> | SNMP agent |
SystemTotalMemEX<p>Update: 10800</p> |
Device firmware revision | <p>-</p> | SNMP agent |
PhysicalFirmwareRev<p>Update: 3600</p> |
Device model name | <p>-</p> | SNMP agent |
ModelNameEX<p>Update: 10800</p> |
CPU usage | <p>System CPU usage</p> | SNMP agent |
SystemCPU-UsageEX<p>Update: 60</p> |
Device system name | <p>Host name</p> | SNMP agent |
HostNameEX<p>Update: 3600</p> |
Speed of {#SNMPVALUE} | <p>-</p> | SNMP agent |
SysFanSpeedEX[{#SNMPINDEX}]<p>Update: 60</p><p>LLD</p> |
Error $2 on $1 | <p>-</p> | SNMP agent |
net.if.err[{#SNMPVALUE},bps]<p>Update: 60</p><p>LLD</p> |
Recived $2 on $1 | <p>-</p> | SNMP agent |
net.if.in[{#SNMPVALUE}, bps]<p>Update: 60</p><p>LLD</p> |
Sent $2 on $1 | <p>-</p> | SNMP agent |
net.if.out[{#SNMPVALUE}, bps]<p>Update: 60</p><p>LLD</p> |
Free size of {#SNMPVALUE} | <p>-</p> | SNMP agent |
SysVolumeFreeSizeEX[{#SNMPINDEX}]<p>Update: 60</p><p>LLD</p> |
Free size of {#SNMPVALUE} (%) | <p>-</p> | Calculated |
SysVolumePFreeSizeEX[{#SNMPINDEX}]<p>Update: 60</p><p>LLD</p> |
Status of {#SNMPVALUE} | <p>-</p> | SNMP agent |
SysVolumeStatusEX[{#SNMPINDEX}]<p>Update: 60</p><p>LLD</p> |
Total size of {#SNMPVALUE} | <p>-</p> | SNMP agent |
SysVolumeTotalSizeEX[{#SNMPINDEX}]<p>Update: 3600</p><p>LLD</p> |
Capacity of {#SNMPVALUE} | <p>-</p> | SNMP agent |
HdCapacityEX[{#SNMPINDEX}]<p>Update: 3600</p><p>LLD</p> |
Model of {#SNMPVALUE} | <p>-</p> | SNMP agent |
HdModelEX[{#SNMPINDEX}]<p>Update: 3600</p><p>LLD</p> |
S.M.A.R.T. info of {#SNMPVALUE} | <p>-</p> | SNMP agent |
HdSmartInfoEX[{#SNMPINDEX}]<p>Update: 60</p><p>LLD</p> |
Status of {#SNMPVALUE} | <p>-</p> | SNMP agent |
HdStatusEX[{#SNMPINDEX}]<p>Update: 60</p><p>LLD</p> |
Temperature of {#SNMPVALUE} | <p>-</p> | SNMP agent |
HdTemperatureEX[{#SNMPINDEX}]<p>Update: 60</p><p>LLD</p> |
Name | Description | Expression | Priority |
---|---|---|---|
SMART state of {#SNMPVALUE} on {HOST.NAME} is ABNORMAL | <p>Abnormal 1. Any SMART value is equal or less than trhreshold. 2. Hard Disk temperature is higher than 65 degree C. ——– QNAP Knowledgebase</p> | <p>Expression: {Template SNMP QNAP NAS:HdSmartInfoEX[{#SNMPINDEX}].iregexp(abnormal)}=1</p><p>Recovery expression: </p> | average |
SMART state of {#SNMPVALUE} on {HOST.NAME} is not GOOD ({ITEM.VALUE1}) | <p>Normal 1. Any Smart value is equal or less than threhold + (initial_SMART_value - threhold)/2. For example, if the initial SMART value is 100, the current value is 50, the threshold is 20, then the Smart value, 50, is less than 20+(100-20)/2. Thus, the health level would be Normal. 2. Any SMART test(Rapid or Complete) result of last 20 times is abnormal. 3. Hard Disk temperature is between 55 to 65 degree C. ——– QNAP Knowledgebase</p> | <p>Expression: {Template SNMP QNAP NAS:HdSmartInfoEX[{#SNMPINDEX}].iregexp(normal)}=1</p><p>Recovery expression: </p> | warning |
State of {#SNMPVALUE} on {HOST.NAME} is “Invalid” | <p>State “Invalid”</p> | <p>Expression: {Template SNMP QNAP NAS:HdStatusEX[{#SNMPINDEX}].last(0)}=-6</p><p>Recovery expression: </p> | warning |
State of {#SNMPVALUE} on {HOST.NAME} is “noDisk” | <p>State “noDisk”</p> | <p>Expression: {Template SNMP QNAP NAS:HdStatusEX[{#SNMPINDEX}].last(0)}=-5</p><p>Recovery expression: </p> | information |
State of {#SNMPVALUE} on {HOST.NAME} is “rwError” | <p>State “rwError”</p> | <p>Expression: {Template SNMP QNAP NAS:HdStatusEX[{#SNMPINDEX}].last(0)}=-9</p><p>Recovery expression: </p> | warning |
State of {#SNMPVALUE} on {HOST.NAME} is not “Ready” ({ITEM.VALUE1}) | <p>-</p> | <p>Expression: {Template SNMP QNAP NAS:HdStatusEX[{#SNMPINDEX}].last(0)}<>0</p><p>Recovery expression: </p> | information |
Temperature of {#SNMPVALUE} on {HOST.NAME} is over {$HD_TEMPERATURE_ALARM} for 2 min | <p>-</p> | <p>Expression: {Template SNMP QNAP NAS:HdTemperatureEX[{#SNMPINDEX}].min(2m)}>51</p><p>Recovery expression: </p> | high |
Temperature of {#SNMPVALUE} on {HOST.NAME} is over {$HD_TEMPERATURE_WARNING} for 2min | <p>-</p> | <p>Expression: {Template SNMP QNAP NAS:HdTemperatureEX[{#SNMPINDEX}].min(2m)}>45</p><p>Recovery expression: </p> | information |
{#SNMPVALUE} fan on {HOST.NAME} possibly is stopped | <p>-</p> | <p>Expression: {Template SNMP QNAP NAS:SysFanSpeedEX[{#SNMPINDEX}].max(60)}=0</p><p>Recovery expression: </p> | warning |
Free space is less than 20% on volume {#SNMPVALUE} | <p>-</p> | <p>Expression: {Template SNMP QNAP NAS:SysVolumePFreeSizeEX[{#SNMPINDEX}].last(0)}<20</p><p>Recovery expression: </p> | warning |
{#SNMPVALUE} fan on {HOST.NAME} possibly is stopped (LLD) | <p>-</p> | <p>Expression: {Template SNMP QNAP NAS:SysFanSpeedEX[{#SNMPINDEX}].max(60)}=0</p><p>Recovery expression: </p> | warning |
Free space is less than 20% on volume {#SNMPVALUE} (LLD) | <p>-</p> | <p>Expression: {Template SNMP QNAP NAS:SysVolumePFreeSizeEX[{#SNMPINDEX}].last(0)}<20</p><p>Recovery expression: </p> | warning |
SMART state of {#SNMPVALUE} on {HOST.NAME} is ABNORMAL (LLD) | <p>Abnormal 1. Any SMART value is equal or less than trhreshold. 2. Hard Disk temperature is higher than 65 degree C. ——– QNAP Knowledgebase</p> | <p>Expression: {Template SNMP QNAP NAS:HdSmartInfoEX[{#SNMPINDEX}].iregexp(abnormal)}=1</p><p>Recovery expression: </p> | average |
SMART state of {#SNMPVALUE} on {HOST.NAME} is not GOOD ({ITEM.VALUE1}) (LLD) | <p>Normal 1. Any Smart value is equal or less than threhold + (initial_SMART_value - threhold)/2. For example, if the initial SMART value is 100, the current value is 50, the threshold is 20, then the Smart value, 50, is less than 20+(100-20)/2. Thus, the health level would be Normal. 2. Any SMART test(Rapid or Complete) result of last 20 times is abnormal. 3. Hard Disk temperature is between 55 to 65 degree C. ——– QNAP Knowledgebase</p> | <p>Expression: {Template SNMP QNAP NAS:HdSmartInfoEX[{#SNMPINDEX}].iregexp(normal)}=1</p><p>Recovery expression: </p> | warning |
State of {#SNMPVALUE} on {HOST.NAME} is “Invalid” (LLD) | <p>State “Invalid”</p> | <p>Expression: {Template SNMP QNAP NAS:HdStatusEX[{#SNMPINDEX}].last(0)}=-6</p><p>Recovery expression: </p> | warning |
State of {#SNMPVALUE} on {HOST.NAME} is “noDisk” (LLD) | <p>State “noDisk”</p> | <p>Expression: {Template SNMP QNAP NAS:HdStatusEX[{#SNMPINDEX}].last(0)}=-5</p><p>Recovery expression: </p> | information |
State of {#SNMPVALUE} on {HOST.NAME} is “rwError” (LLD) | <p>State “rwError”</p> | <p>Expression: {Template SNMP QNAP NAS:HdStatusEX[{#SNMPINDEX}].last(0)}=-9</p><p>Recovery expression: </p> | warning |
State of {#SNMPVALUE} on {HOST.NAME} is not “Ready” ({ITEM.VALUE1}) (LLD) | <p>-</p> | <p>Expression: {Template SNMP QNAP NAS:HdStatusEX[{#SNMPINDEX}].last(0)}<>0</p><p>Recovery expression: </p> | information |
Temperature of {#SNMPVALUE} on {HOST.NAME} is over {$HD_TEMPERATURE_ALARM} for 2 min (LLD) | <p>-</p> | <p>Expression: {Template SNMP QNAP NAS:HdTemperatureEX[{#SNMPINDEX}].min(2m)}>51</p><p>Recovery expression: </p> | high |
Temperature of {#SNMPVALUE} on {HOST.NAME} is over {$HD_TEMPERATURE_WARNING} for 2min (LLD) | <p>-</p> | <p>Expression: {Template SNMP QNAP NAS:HdTemperatureEX[{#SNMPINDEX}].min(2m)}>45</p><p>Recovery expression: </p> | information |
Name | Description | Default | Type |
---|---|---|---|
{$HD_TEMPERATURE_ALARM} | <p>-</p> | 51 |
Text macro |
{$HD_TEMPERATURE_WARNING} | <p>-</p> | 45 |
Text macro |
There are no template links in this template.
Name | Description | Type | Key and additional info |
---|---|---|---|
System fans discovery | <p>-</p> | SNMP agent |
sysFans.discovery<p>Update: 3600</p> |
Network interfaces discovery | <p>-</p> | SNMP agent |
netIfs.discovery<p>Update: 3600</p> |
Hard disks discovery | <p>-</p> | SNMP agent |
sysHDs.discovery<p>Update: 3600</p> |
Volumes discovery | <p>-</p> | SNMP agent |
sysVolumes.discovery<p>Update: 3600</p> |
Name | Description | Type | Key and additional info |
---|---|---|---|
Device model name | <p>-</p> | SNMP agent |
ModelNameEX<p>Update: 10800</p> |
System total memory | <p>-</p> | SNMP agent |
SystemTotalMemEX<p>Update: 10800</p> |
Device system name | <p>Host name</p> | SNMP agent |
HostNameEX<p>Update: 3600</p> |
Device software revision | <p>-</p> | SNMP agent |
PhysicalSoftwareRev<p>Update: 3600</p> |
System uptime | <p>-</p> | SNMP agent |
system.uptime[sysUpTime]<p>Update: 30s</p> |
CPU temperature | <p>CPU temperature in centigrade</p> | SNMP agent |
CPU-TemperatureEX<p>Update: 60</p> |
Device hardware revision | <p>-</p> | SNMP agent |
PhysicalHardwareRev<p>Update: 10800</p> |
CPU usage | <p>System CPU usage</p> | SNMP agent |
SystemCPU-UsageEX<p>Update: 60</p> |
System free memory (%) | <p>-</p> | Calculated |
SystemPFreeMemEX<p>Update: 60</p> |
Device firmware revision | <p>-</p> | SNMP agent |
PhysicalFirmwareRev<p>Update: 3600</p> |
System temperature | <p>System temperature in centigrade</p> | SNMP agent |
SystemTemperatureEX<p>Update: 60</p> |
System free memory | <p>-</p> | SNMP agent |
SystemFreeMemEX<p>Update: 60</p> |
Device vendor name | <p>-</p> | SNMP agent |
sysPhysicalMfgName<p>Update: 3600</p> |
Speed of {#SNMPVALUE} | <p>-</p> | SNMP agent |
SysFanSpeedEX[{#SNMPINDEX}]<p>Update: 60</p><p>LLD</p> |
Error $2 on $1 | <p>-</p> | SNMP agent |
net.if.err[{#SNMPVALUE},bps]<p>Update: 60</p><p>LLD</p> |
Recived $2 on $1 | <p>-</p> | SNMP agent |
net.if.in[{#SNMPVALUE}, bps]<p>Update: 60</p><p>LLD</p> |
Sent $2 on $1 | <p>-</p> | SNMP agent |
net.if.out[{#SNMPVALUE}, bps]<p>Update: 60</p><p>LLD</p> |
Capacity of {#SNMPVALUE} | <p>-</p> | SNMP agent |
HdCapacityEX[{#SNMPINDEX}]<p>Update: 3600</p><p>LLD</p> |
Model of {#SNMPVALUE} | <p>-</p> | SNMP agent |
HdModelEX[{#SNMPINDEX}]<p>Update: 3600</p><p>LLD</p> |
S.M.A.R.T. info of {#SNMPVALUE} | <p>-</p> | SNMP agent |
HdSmartInfoEX[{#SNMPINDEX}]<p>Update: 60</p><p>LLD</p> |
Status of {#SNMPVALUE} | <p>-</p> | SNMP agent |
HdStatusEX[{#SNMPINDEX}]<p>Update: 60</p><p>LLD</p> |
Temperature of {#SNMPVALUE} | <p>-</p> | SNMP agent |
HdTemperatureEX[{#SNMPINDEX}]<p>Update: 60</p><p>LLD</p> |
Free size of {#SNMPVALUE} | <p>-</p> | SNMP agent |
SysVolumeFreeSizeEX[{#SNMPINDEX}]<p>Update: 60</p><p>LLD</p> |
Free size of {#SNMPVALUE} (%) | <p>-</p> | Calculated |
SysVolumePFreeSizeEX[{#SNMPINDEX}]<p>Update: 60</p><p>LLD</p> |
Status of {#SNMPVALUE} | <p>-</p> | SNMP agent |
SysVolumeStatusEX[{#SNMPINDEX}]<p>Update: 60</p><p>LLD</p> |
Total size of {#SNMPVALUE} | <p>-</p> | SNMP agent |
SysVolumeTotalSizeEX[{#SNMPINDEX}]<p>Update: 3600</p><p>LLD</p> |
Name | Description | Expression | Priority |
---|---|---|---|
SMART state of {#SNMPVALUE} on {HOST.NAME} is ABNORMAL | <p>Abnormal 1. Any SMART value is equal or less than trhreshold. 2. Hard Disk temperature is higher than 65 degree C. ——– QNAP Knowledgebase</p> | <p>Expression: find(/Template SNMP QNAP NAS/HdSmartInfoEX[{#SNMPINDEX}],,”iregexp”,”abnormal”)=1</p><p>Recovery expression: </p> | average |
SMART state of {#SNMPVALUE} on {HOST.NAME} is not GOOD ({ITEM.VALUE1}) | <p>Normal 1. Any Smart value is equal or less than threhold + (initial_SMART_value - threhold)/2. For example, if the initial SMART value is 100, the current value is 50, the threshold is 20, then the Smart value, 50, is less than 20+(100-20)/2. Thus, the health level would be Normal. 2. Any SMART test(Rapid or Complete) result of last 20 times is abnormal. 3. Hard Disk temperature is between 55 to 65 degree C. ——– QNAP Knowledgebase</p> | <p>Expression: find(/Template SNMP QNAP NAS/HdSmartInfoEX[{#SNMPINDEX}],,”iregexp”,”normal”)=1</p><p>Recovery expression: </p> | warning |
State of {#SNMPVALUE} on {HOST.NAME} is “Invalid” | <p>State “Invalid”</p> | <p>Expression: last(/Template SNMP QNAP NAS/HdStatusEX[{#SNMPINDEX}])=-6</p><p>Recovery expression: </p> | warning |
State of {#SNMPVALUE} on {HOST.NAME} is “noDisk” | <p>State “noDisk”</p> | <p>Expression: last(/Template SNMP QNAP NAS/HdStatusEX[{#SNMPINDEX}])=-5</p><p>Recovery expression: </p> | information |
State of {#SNMPVALUE} on {HOST.NAME} is “rwError” | <p>State “rwError”</p> | <p>Expression: last(/Template SNMP QNAP NAS/HdStatusEX[{#SNMPINDEX}])=-9</p><p>Recovery expression: </p> | warning |
State of {#SNMPVALUE} on {HOST.NAME} is not “Ready” ({ITEM.VALUE1}) | <p>-</p> | <p>Expression: last(/Template SNMP QNAP NAS/HdStatusEX[{#SNMPINDEX}])<>0</p><p>Recovery expression: </p> | information |
Temperature of {#SNMPVALUE} on {HOST.NAME} is over {$HD_TEMPERATURE_ALARM} for 2 min | <p>-</p> | <p>Expression: min(/Template SNMP QNAP NAS/HdTemperatureEX[{#SNMPINDEX}],2m)>51</p><p>Recovery expression: </p> | high |
Temperature of {#SNMPVALUE} on {HOST.NAME} is over {$HD_TEMPERATURE_WARNING} for 2min | <p>-</p> | <p>Expression: min(/Template SNMP QNAP NAS/HdTemperatureEX[{#SNMPINDEX}],2m)>45</p><p>Recovery expression: </p> | information |
{#SNMPVALUE} fan on {HOST.NAME} possibly is stopped | <p>-</p> | <p>Expression: max(/Template SNMP QNAP NAS/SysFanSpeedEX[{#SNMPINDEX}],60s)=0</p><p>Recovery expression: </p> | warning |
Free space is less than 20% on volume {#SNMPVALUE} | <p>-</p> | <p>Expression: last(/Template SNMP QNAP NAS/SysVolumePFreeSizeEX[{#SNMPINDEX}])<20</p><p>Recovery expression: </p> | warning |
{#SNMPVALUE} fan on {HOST.NAME} possibly is stopped (LLD) | <p>-</p> | <p>Expression: max(/Template SNMP QNAP NAS/SysFanSpeedEX[{#SNMPINDEX}],60s)=0</p><p>Recovery expression: </p> | warning |
SMART state of {#SNMPVALUE} on {HOST.NAME} is ABNORMAL (LLD) | <p>Abnormal 1. Any SMART value is equal or less than trhreshold. 2. Hard Disk temperature is higher than 65 degree C. ——– QNAP Knowledgebase</p> | <p>Expression: find(/Template SNMP QNAP NAS/HdSmartInfoEX[{#SNMPINDEX}],,”iregexp”,”abnormal”)=1</p><p>Recovery expression: </p> | average |
SMART state of {#SNMPVALUE} on {HOST.NAME} is not GOOD ({ITEM.VALUE1}) (LLD) | <p>Normal 1. Any Smart value is equal or less than threhold + (initial_SMART_value - threhold)/2. For example, if the initial SMART value is 100, the current value is 50, the threshold is 20, then the Smart value, 50, is less than 20+(100-20)/2. Thus, the health level would be Normal. 2. Any SMART test(Rapid or Complete) result of last 20 times is abnormal. 3. Hard Disk temperature is between 55 to 65 degree C. ——– QNAP Knowledgebase</p> | <p>Expression: find(/Template SNMP QNAP NAS/HdSmartInfoEX[{#SNMPINDEX}],,”iregexp”,”normal”)=1</p><p>Recovery expression: </p> | warning |
State of {#SNMPVALUE} on {HOST.NAME} is “Invalid” (LLD) | <p>State “Invalid”</p> | <p>Expression: last(/Template SNMP QNAP NAS/HdStatusEX[{#SNMPINDEX}])=-6</p><p>Recovery expression: </p> | warning |
State of {#SNMPVALUE} on {HOST.NAME} is “noDisk” (LLD) | <p>State “noDisk”</p> | <p>Expression: last(/Template SNMP QNAP NAS/HdStatusEX[{#SNMPINDEX}])=-5</p><p>Recovery expression: </p> | information |
State of {#SNMPVALUE} on {HOST.NAME} is “rwError” (LLD) | <p>State “rwError”</p> | <p>Expression: last(/Template SNMP QNAP NAS/HdStatusEX[{#SNMPINDEX}])=-9</p><p>Recovery expression: </p> | warning |
State of {#SNMPVALUE} on {HOST.NAME} is not “Ready” ({ITEM.VALUE1}) (LLD) | <p>-</p> | <p>Expression: last(/Template SNMP QNAP NAS/HdStatusEX[{#SNMPINDEX}])<>0</p><p>Recovery expression: </p> | information |
Temperature of {#SNMPVALUE} on {HOST.NAME} is over {$HD_TEMPERATURE_ALARM} for 2 min (LLD) | <p>-</p> | <p>Expression: min(/Template SNMP QNAP NAS/HdTemperatureEX[{#SNMPINDEX}],2m)>51</p><p>Recovery expression: </p> | high |
Temperature of {#SNMPVALUE} on {HOST.NAME} is over {$HD_TEMPERATURE_WARNING} for 2min (LLD) | <p>-</p> | <p>Expression: min(/Template SNMP QNAP NAS/HdTemperatureEX[{#SNMPINDEX}],2m)>45</p><p>Recovery expression: </p> | information |
Free space is less than 20% on volume {#SNMPVALUE} (LLD) | <p>-</p> | <p>Expression: last(/Template SNMP QNAP NAS/SysVolumePFreeSizeEX[{#SNMPINDEX}])<20</p><p>Recovery expression: </p> | warning |
Name | Description | Default | Type |
---|---|---|---|
{$HD_TEMPERATURE_ALARM} | <p>-</p> | 51 |
Text macro |
{$HD_TEMPERATURE_WARNING} | <p>-</p> | 45 |
Text macro |
There are no template links in this template.
Name | Description | Type | Key and additional info |
---|---|---|---|
System fans discovery | <p>-</p> | SNMP agent |
sysFans.discovery<p>Update: 3600</p> |
Network interfaces discovery | <p>-</p> | SNMP agent |
netIfs.discovery<p>Update: 3600</p> |
Hard disks discovery | <p>-</p> | SNMP agent |
sysHDs.discovery<p>Update: 3600</p> |
Volumes discovery | <p>-</p> | SNMP agent |
sysVolumes.discovery<p>Update: 3600</p> |
Name | Description | Type | Key and additional info |
---|---|---|---|
Device model name | <p>-</p> | SNMP agent |
ModelNameEX<p>Update: 10800</p> |
System total memory | <p>-</p> | SNMP agent |
SystemTotalMemEX<p>Update: 10800</p> |
Device system name | <p>Host name</p> | SNMP agent |
HostNameEX<p>Update: 3600</p> |
Device software revision | <p>-</p> | SNMP agent |
PhysicalSoftwareRev<p>Update: 3600</p> |
System uptime | <p>-</p> | SNMP agent |
system.uptime[sysUpTime]<p>Update: 30s</p> |
CPU temperature | <p>CPU temperature in centigrade</p> | SNMP agent |
CPU-TemperatureEX<p>Update: 60</p> |
Device hardware revision | <p>-</p> | SNMP agent |
PhysicalHardwareRev<p>Update: 10800</p> |
CPU usage | <p>System CPU usage</p> | SNMP agent |
SystemCPU-UsageEX<p>Update: 60</p> |
System free memory (%) | <p>-</p> | Calculated |
SystemPFreeMemEX<p>Update: 60</p> |
Device firmware revision | <p>-</p> | SNMP agent |
PhysicalFirmwareRev<p>Update: 3600</p> |
System temperature | <p>System temperature in centigrade</p> | SNMP agent |
SystemTemperatureEX<p>Update: 60</p> |
System free memory | <p>-</p> | SNMP agent |
SystemFreeMemEX<p>Update: 60</p> |
Device vendor name | <p>-</p> | SNMP agent |
sysPhysicalMfgName<p>Update: 3600</p> |
Speed of {#SNMPVALUE} | <p>-</p> | SNMP agent |
SysFanSpeedEX[{#SNMPINDEX}]<p>Update: 60</p><p>LLD</p> |
Error $2 on $1 | <p>-</p> | SNMP agent |
net.if.err[{#SNMPVALUE},bps]<p>Update: 60</p><p>LLD</p> |
Recived $2 on $1 | <p>-</p> | SNMP agent |
net.if.in[{#SNMPVALUE}, bps]<p>Update: 60</p><p>LLD</p> |
Sent $2 on $1 | <p>-</p> | SNMP agent |
net.if.out[{#SNMPVALUE}, bps]<p>Update: 60</p><p>LLD</p> |
Capacity of {#SNMPVALUE} | <p>-</p> | SNMP agent |
HdCapacityEX[{#SNMPINDEX}]<p>Update: 3600</p><p>LLD</p> |
Model of {#SNMPVALUE} | <p>-</p> | SNMP agent |
HdModelEX[{#SNMPINDEX}]<p>Update: 3600</p><p>LLD</p> |
S.M.A.R.T. info of {#SNMPVALUE} | <p>-</p> | SNMP agent |
HdSmartInfoEX[{#SNMPINDEX}]<p>Update: 60</p><p>LLD</p> |
Status of {#SNMPVALUE} | <p>-</p> | SNMP agent |
HdStatusEX[{#SNMPINDEX}]<p>Update: 60</p><p>LLD</p> |
Temperature of {#SNMPVALUE} | <p>-</p> | SNMP agent |
HdTemperatureEX[{#SNMPINDEX}]<p>Update: 60</p><p>LLD</p> |
Free size of {#SNMPVALUE} | <p>-</p> | SNMP agent |
SysVolumeFreeSizeEX[{#SNMPINDEX}]<p>Update: 60</p><p>LLD</p> |
Free size of {#SNMPVALUE} (%) | <p>-</p> | Calculated |
SysVolumePFreeSizeEX[{#SNMPINDEX}]<p>Update: 60</p><p>LLD</p> |
Status of {#SNMPVALUE} | <p>-</p> | SNMP agent |
SysVolumeStatusEX[{#SNMPINDEX}]<p>Update: 60</p><p>LLD</p> |
Total size of {#SNMPVALUE} | <p>-</p> | SNMP agent |
SysVolumeTotalSizeEX[{#SNMPINDEX}]<p>Update: 3600</p><p>LLD</p> |
Name | Description | Expression | Priority |
---|---|---|---|
SMART state of {#SNMPVALUE} on {HOST.NAME} is ABNORMAL | <p>Abnormal 1. Any SMART value is equal or less than trhreshold. 2. Hard Disk temperature is higher than 65 degree C. ——– QNAP Knowledgebase</p> | <p>Expression: find(/Template SNMP QNAP NAS/HdSmartInfoEX[{#SNMPINDEX}],,”iregexp”,”abnormal”)=1</p><p>Recovery expression: </p> | average |
SMART state of {#SNMPVALUE} on {HOST.NAME} is not GOOD ({ITEM.VALUE1}) | <p>Normal 1. Any Smart value is equal or less than threhold + (initial_SMART_value - threhold)/2. For example, if the initial SMART value is 100, the current value is 50, the threshold is 20, then the Smart value, 50, is less than 20+(100-20)/2. Thus, the health level would be Normal. 2. Any SMART test(Rapid or Complete) result of last 20 times is abnormal. 3. Hard Disk temperature is between 55 to 65 degree C. ——– QNAP Knowledgebase</p> | <p>Expression: find(/Template SNMP QNAP NAS/HdSmartInfoEX[{#SNMPINDEX}],,”iregexp”,”normal”)=1</p><p>Recovery expression: </p> | warning |
State of {#SNMPVALUE} on {HOST.NAME} is “Invalid” | <p>State “Invalid”</p> | <p>Expression: last(/Template SNMP QNAP NAS/HdStatusEX[{#SNMPINDEX}])=-6</p><p>Recovery expression: </p> | warning |
State of {#SNMPVALUE} on {HOST.NAME} is “noDisk” | <p>State “noDisk”</p> | <p>Expression: last(/Template SNMP QNAP NAS/HdStatusEX[{#SNMPINDEX}])=-5</p><p>Recovery expression: </p> | information |
State of {#SNMPVALUE} on {HOST.NAME} is “rwError” | <p>State “rwError”</p> | <p>Expression: last(/Template SNMP QNAP NAS/HdStatusEX[{#SNMPINDEX}])=-9</p><p>Recovery expression: </p> | warning |
State of {#SNMPVALUE} on {HOST.NAME} is not “Ready” ({ITEM.VALUE1}) | <p>-</p> | <p>Expression: last(/Template SNMP QNAP NAS/HdStatusEX[{#SNMPINDEX}])<>0</p><p>Recovery expression: </p> | information |
Temperature of {#SNMPVALUE} on {HOST.NAME} is over {$HD_TEMPERATURE_ALARM} for 2 min | <p>-</p> | <p>Expression: min(/Template SNMP QNAP NAS/HdTemperatureEX[{#SNMPINDEX}],2m)>51</p><p>Recovery expression: </p> | high |
Temperature of {#SNMPVALUE} on {HOST.NAME} is over {$HD_TEMPERATURE_WARNING} for 2min | <p>-</p> | <p>Expression: min(/Template SNMP QNAP NAS/HdTemperatureEX[{#SNMPINDEX}],2m)>45</p><p>Recovery expression: </p> | information |
{#SNMPVALUE} fan on {HOST.NAME} possibly is stopped | <p>-</p> | <p>Expression: max(/Template SNMP QNAP NAS/SysFanSpeedEX[{#SNMPINDEX}],60s)=0</p><p>Recovery expression: </p> | warning |
Free space is less than 20% on volume {#SNMPVALUE} | <p>-</p> | <p>Expression: last(/Template SNMP QNAP NAS/SysVolumePFreeSizeEX[{#SNMPINDEX}])<20</p><p>Recovery expression: </p> | warning |
{#SNMPVALUE} fan on {HOST.NAME} possibly is stopped (LLD) | <p>-</p> | <p>Expression: max(/Template SNMP QNAP NAS/SysFanSpeedEX[{#SNMPINDEX}],60s)=0</p><p>Recovery expression: </p> | warning |
SMART state of {#SNMPVALUE} on {HOST.NAME} is ABNORMAL (LLD) | <p>Abnormal 1. Any SMART value is equal or less than trhreshold. 2. Hard Disk temperature is higher than 65 degree C. ——– QNAP Knowledgebase</p> | <p>Expression: find(/Template SNMP QNAP NAS/HdSmartInfoEX[{#SNMPINDEX}],,”iregexp”,”abnormal”)=1</p><p>Recovery expression: </p> | average |
SMART state of {#SNMPVALUE} on {HOST.NAME} is not GOOD ({ITEM.VALUE1}) (LLD) | <p>Normal 1. Any Smart value is equal or less than threhold + (initial_SMART_value - threhold)/2. For example, if the initial SMART value is 100, the current value is 50, the threshold is 20, then the Smart value, 50, is less than 20+(100-20)/2. Thus, the health level would be Normal. 2. Any SMART test(Rapid or Complete) result of last 20 times is abnormal. 3. Hard Disk temperature is between 55 to 65 degree C. ——– QNAP Knowledgebase</p> | <p>Expression: find(/Template SNMP QNAP NAS/HdSmartInfoEX[{#SNMPINDEX}],,”iregexp”,”normal”)=1</p><p>Recovery expression: </p> | warning |
State of {#SNMPVALUE} on {HOST.NAME} is “Invalid” (LLD) | <p>State “Invalid”</p> | <p>Expression: last(/Template SNMP QNAP NAS/HdStatusEX[{#SNMPINDEX}])=-6</p><p>Recovery expression: </p> | warning |
State of {#SNMPVALUE} on {HOST.NAME} is “noDisk” (LLD) | <p>State “noDisk”</p> | <p>Expression: last(/Template SNMP QNAP NAS/HdStatusEX[{#SNMPINDEX}])=-5</p><p>Recovery expression: </p> | information |
State of {#SNMPVALUE} on {HOST.NAME} is “rwError” (LLD) | <p>State “rwError”</p> | <p>Expression: last(/Template SNMP QNAP NAS/HdStatusEX[{#SNMPINDEX}])=-9</p><p>Recovery expression: </p> | warning |
State of {#SNMPVALUE} on {HOST.NAME} is not “Ready” ({ITEM.VALUE1}) (LLD) | <p>-</p> | <p>Expression: last(/Template SNMP QNAP NAS/HdStatusEX[{#SNMPINDEX}])<>0</p><p>Recovery expression: </p> | information |
Temperature of {#SNMPVALUE} on {HOST.NAME} is over {$HD_TEMPERATURE_ALARM} for 2 min (LLD) | <p>-</p> | <p>Expression: min(/Template SNMP QNAP NAS/HdTemperatureEX[{#SNMPINDEX}],2m)>51</p><p>Recovery expression: </p> | high |
Temperature of {#SNMPVALUE} on {HOST.NAME} is over {$HD_TEMPERATURE_WARNING} for 2min (LLD) | <p>-</p> | <p>Expression: min(/Template SNMP QNAP NAS/HdTemperatureEX[{#SNMPINDEX}],2m)>45</p><p>Recovery expression: </p> | information |
Free space is less than 20% on volume {#SNMPVALUE} (LLD) | <p>-</p> | <p>Expression: last(/Template SNMP QNAP NAS/SysVolumePFreeSizeEX[{#SNMPINDEX}])<20</p><p>Recovery expression: </p> | warning |