Available versions




Template SNMP QNAP NAS

Macros used

Name Description Default Type
{$HD_TEMPERATURE_ALARM} <p>-</p> 51 Text macro
{$HD_TEMPERATURE_WARNING} <p>-</p> 40 Text macro

There are no template links in this template.

Discovery rules

Name Description Type Key and additional info
System fans discovery <p>-</p> SNMP agent sysFans.discovery<p>Update: 3600</p>
Network interfaces discovery <p>-</p> SNMP agent netIfs.discovery<p>Update: 3600</p>
Volumes discovery <p>-</p> SNMP agent sysVolumes.discovery<p>Update: 3600</p>
Hard disks discovery <p>-</p> SNMP agent sysHDs.discovery<p>Update: 3600</p>

Items collected

Name Description Type Key and additional info
Device hardware revision <p>-</p> SNMP agent PhysicalHardwareRev<p>Update: 10800</p>
System uptime <p>-</p> SNMP agent sysUptime<p>Update: 60</p>
Device vendor name <p>-</p> SNMP agent sysPhysicalMfgName<p>Update: 3600</p>
Device software revision <p>-</p> SNMP agent PhysicalSoftwareRev<p>Update: 3600</p>
CPU temperature <p>CPU temperature in centigrade</p> SNMP agent CPU-TemperatureEX<p>Update: 60</p>
System free memory <p>-</p> SNMP agent SystemFreeMemEX<p>Update: 60</p>
System free memory (%) <p>-</p> Calculated SystemPFreeMemEX<p>Update: 60</p>
System temperature <p>System temperature in centigrade</p> SNMP agent SystemTemperatureEX<p>Update: 60</p>
System total memory <p>-</p> SNMP agent SystemTotalMemEX<p>Update: 10800</p>
Device firmware revision <p>-</p> SNMP agent PhysicalFirmwareRev<p>Update: 3600</p>
Device model name <p>-</p> SNMP agent ModelNameEX<p>Update: 10800</p>
CPU usage <p>System CPU usage</p> SNMP agent SystemCPU-UsageEX<p>Update: 60</p>
Device system name <p>Host name</p> SNMP agent HostNameEX<p>Update: 3600</p>
Speed of {#SNMPVALUE} <p>-</p> SNMP agent SysFanSpeedEX[{#SNMPINDEX}]<p>Update: 60</p><p>LLD</p>
Error $2 on $1 <p>-</p> SNMP agent net.if.err[{#SNMPVALUE},bps]<p>Update: 60</p><p>LLD</p>
Recived $2 on $1 <p>-</p> SNMP agent net.if.in[{#SNMPVALUE}, bps]<p>Update: 60</p><p>LLD</p>
Sent $2 on $1 <p>-</p> SNMP agent net.if.out[{#SNMPVALUE}, bps]<p>Update: 60</p><p>LLD</p>
Free size of {#SNMPVALUE} <p>-</p> SNMP agent SysVolumeFreeSizeEX[{#SNMPINDEX}]<p>Update: 60</p><p>LLD</p>
Free size of {#SNMPVALUE} (%) <p>-</p> Calculated SysVolumePFreeSizeEX[{#SNMPINDEX}]<p>Update: 60</p><p>LLD</p>
Status of {#SNMPVALUE} <p>-</p> SNMP agent SysVolumeStatusEX[{#SNMPINDEX}]<p>Update: 60</p><p>LLD</p>
Total size of {#SNMPVALUE} <p>-</p> SNMP agent SysVolumeTotalSizeEX[{#SNMPINDEX}]<p>Update: 3600</p><p>LLD</p>
Capacity of {#SNMPVALUE} <p>-</p> SNMP agent HdCapacityEX[{#SNMPINDEX}]<p>Update: 3600</p><p>LLD</p>
Model of {#SNMPVALUE} <p>-</p> SNMP agent HdModelEX[{#SNMPINDEX}]<p>Update: 3600</p><p>LLD</p>
S.M.A.R.T. info of {#SNMPVALUE} <p>-</p> SNMP agent HdSmartInfoEX[{#SNMPINDEX}]<p>Update: 60</p><p>LLD</p>
Status of {#SNMPVALUE} <p>-</p> SNMP agent HdStatusEX[{#SNMPINDEX}]<p>Update: 60</p><p>LLD</p>
Temperature of {#SNMPVALUE} <p>-</p> SNMP agent HdTemperatureEX[{#SNMPINDEX}]<p>Update: 60</p><p>LLD</p>

Triggers

Name Description Expression Priority
SMART state of {#SNMPVALUE} on {HOST.NAME} is ABNORMAL <p>Abnormal 1. Any SMART value is equal or less than trhreshold. 2. Hard Disk temperature is higher than 65 degree C. ——– QNAP Knowledgebase</p> <p>Expression: {Template SNMP QNAP NAS:HdSmartInfoEX[{#SNMPINDEX}].iregexp(abnormal)}=1</p><p>Recovery expression: </p> average
SMART state of {#SNMPVALUE} on {HOST.NAME} is not GOOD ({ITEM.VALUE1}) <p>Normal 1. Any Smart value is equal or less than threhold + (initial_SMART_value - threhold)/2. For example, if the initial SMART value is 100, the current value is 50, the threshold is 20, then the Smart value, 50, is less than 20+(100-20)/2. Thus, the health level would be Normal. 2. Any SMART test(Rapid or Complete) result of last 20 times is abnormal. 3. Hard Disk temperature is between 55 to 65 degree C. ——– QNAP Knowledgebase</p> <p>Expression: {Template SNMP QNAP NAS:HdSmartInfoEX[{#SNMPINDEX}].iregexp(normal)}=1</p><p>Recovery expression: </p> warning
State of {#SNMPVALUE} on {HOST.NAME} is “Invalid” <p>State “Invalid”</p> <p>Expression: {Template SNMP QNAP NAS:HdStatusEX[{#SNMPINDEX}].last(0)}=-6</p><p>Recovery expression: </p> warning
State of {#SNMPVALUE} on {HOST.NAME} is “noDisk” <p>State “noDisk”</p> <p>Expression: {Template SNMP QNAP NAS:HdStatusEX[{#SNMPINDEX}].last(0)}=-5</p><p>Recovery expression: </p> information
State of {#SNMPVALUE} on {HOST.NAME} is “rwError” <p>State “rwError”</p> <p>Expression: {Template SNMP QNAP NAS:HdStatusEX[{#SNMPINDEX}].last(0)}=-9</p><p>Recovery expression: </p> warning
State of {#SNMPVALUE} on {HOST.NAME} is not “Ready” ({ITEM.VALUE1}) <p>-</p> <p>Expression: {Template SNMP QNAP NAS:HdStatusEX[{#SNMPINDEX}].last(0)}<>0</p><p>Recovery expression: </p> information
Temperature of {#SNMPVALUE} on {HOST.NAME} is over {$HD_TEMPERATURE_ALARM} for 2 min <p>-</p> <p>Expression: {Template SNMP QNAP NAS:HdTemperatureEX[{#SNMPINDEX}].min(2m)}>51</p><p>Recovery expression: </p> high
Temperature of {#SNMPVALUE} on {HOST.NAME} is over {$HD_TEMPERATURE_WARNING} for 2min <p>-</p> <p>Expression: {Template SNMP QNAP NAS:HdTemperatureEX[{#SNMPINDEX}].min(2m)}>40</p><p>Recovery expression: </p> information
{#SNMPVALUE} fan on {HOST.NAME} possibly is stopped <p>-</p> <p>Expression: {Template SNMP QNAP NAS:SysFanSpeedEX[{#SNMPINDEX}].max(60)}=0</p><p>Recovery expression: </p> warning
Free space is less than 20% on volume {#SNMPVALUE} <p>-</p> <p>Expression: {Template SNMP QNAP NAS:SysVolumePFreeSizeEX[{#SNMPINDEX}].last(0)}<20</p><p>Recovery expression: </p> warning
{#SNMPVALUE} fan on {HOST.NAME} possibly is stopped (LLD) <p>-</p> <p>Expression: {Template SNMP QNAP NAS:SysFanSpeedEX[{#SNMPINDEX}].max(60)}=0</p><p>Recovery expression: </p> warning
Free space is less than 20% on volume {#SNMPVALUE} (LLD) <p>-</p> <p>Expression: {Template SNMP QNAP NAS:SysVolumePFreeSizeEX[{#SNMPINDEX}].last(0)}<20</p><p>Recovery expression: </p> warning
SMART state of {#SNMPVALUE} on {HOST.NAME} is ABNORMAL (LLD) <p>Abnormal 1. Any SMART value is equal or less than trhreshold. 2. Hard Disk temperature is higher than 65 degree C. ——– QNAP Knowledgebase</p> <p>Expression: {Template SNMP QNAP NAS:HdSmartInfoEX[{#SNMPINDEX}].iregexp(abnormal)}=1</p><p>Recovery expression: </p> average
SMART state of {#SNMPVALUE} on {HOST.NAME} is not GOOD ({ITEM.VALUE1}) (LLD) <p>Normal 1. Any Smart value is equal or less than threhold + (initial_SMART_value - threhold)/2. For example, if the initial SMART value is 100, the current value is 50, the threshold is 20, then the Smart value, 50, is less than 20+(100-20)/2. Thus, the health level would be Normal. 2. Any SMART test(Rapid or Complete) result of last 20 times is abnormal. 3. Hard Disk temperature is between 55 to 65 degree C. ——– QNAP Knowledgebase</p> <p>Expression: {Template SNMP QNAP NAS:HdSmartInfoEX[{#SNMPINDEX}].iregexp(normal)}=1</p><p>Recovery expression: </p> warning
State of {#SNMPVALUE} on {HOST.NAME} is “Invalid” (LLD) <p>State “Invalid”</p> <p>Expression: {Template SNMP QNAP NAS:HdStatusEX[{#SNMPINDEX}].last(0)}=-6</p><p>Recovery expression: </p> warning
State of {#SNMPVALUE} on {HOST.NAME} is “noDisk” (LLD) <p>State “noDisk”</p> <p>Expression: {Template SNMP QNAP NAS:HdStatusEX[{#SNMPINDEX}].last(0)}=-5</p><p>Recovery expression: </p> information
State of {#SNMPVALUE} on {HOST.NAME} is “rwError” (LLD) <p>State “rwError”</p> <p>Expression: {Template SNMP QNAP NAS:HdStatusEX[{#SNMPINDEX}].last(0)}=-9</p><p>Recovery expression: </p> warning
State of {#SNMPVALUE} on {HOST.NAME} is not “Ready” ({ITEM.VALUE1}) (LLD) <p>-</p> <p>Expression: {Template SNMP QNAP NAS:HdStatusEX[{#SNMPINDEX}].last(0)}<>0</p><p>Recovery expression: </p> information
Temperature of {#SNMPVALUE} on {HOST.NAME} is over {$HD_TEMPERATURE_ALARM} for 2 min (LLD) <p>-</p> <p>Expression: {Template SNMP QNAP NAS:HdTemperatureEX[{#SNMPINDEX}].min(2m)}>51</p><p>Recovery expression: </p> high
Temperature of {#SNMPVALUE} on {HOST.NAME} is over {$HD_TEMPERATURE_WARNING} for 2min (LLD) <p>-</p> <p>Expression: {Template SNMP QNAP NAS:HdTemperatureEX[{#SNMPINDEX}].min(2m)}>40</p><p>Recovery expression: </p> information

Template SNMP QNAP NAS

Macros used

Name Description Default Type
{$HD_TEMPERATURE_ALARM} <p>-</p> 51 Text macro
{$HD_TEMPERATURE_WARNING} <p>-</p> 40 Text macro

There are no template links in this template.

Discovery rules

Name Description Type Key and additional info
System fans discovery <p>-</p> SNMP agent sysFans.discovery<p>Update: 3600</p>
Network interfaces discovery <p>-</p> SNMP agent netIfs.discovery<p>Update: 3600</p>
Hard disks discovery <p>-</p> SNMP agent sysHDs.discovery<p>Update: 3600</p>
Volumes discovery <p>-</p> SNMP agent sysVolumes.discovery<p>Update: 3600</p>

Items collected

Name Description Type Key and additional info
Device model name <p>-</p> SNMP agent ModelNameEX<p>Update: 10800</p>
System total memory <p>-</p> SNMP agent SystemTotalMemEX<p>Update: 10800</p>
Device system name <p>Host name</p> SNMP agent HostNameEX<p>Update: 3600</p>
Device software revision <p>-</p> SNMP agent PhysicalSoftwareRev<p>Update: 3600</p>
CPU temperature <p>CPU temperature in centigrade</p> SNMP agent CPU-TemperatureEX<p>Update: 60</p>
Device hardware revision <p>-</p> SNMP agent PhysicalHardwareRev<p>Update: 10800</p>
CPU usage <p>System CPU usage</p> SNMP agent SystemCPU-UsageEX<p>Update: 60</p>
System free memory (%) <p>-</p> Calculated SystemPFreeMemEX<p>Update: 60</p>
System uptime <p>-</p> SNMP agent sysUptime<p>Update: 60</p>
Device firmware revision <p>-</p> SNMP agent PhysicalFirmwareRev<p>Update: 3600</p>
System temperature <p>System temperature in centigrade</p> SNMP agent SystemTemperatureEX<p>Update: 60</p>
System free memory <p>-</p> SNMP agent SystemFreeMemEX<p>Update: 60</p>
Device vendor name <p>-</p> SNMP agent sysPhysicalMfgName<p>Update: 3600</p>
Speed of {#SNMPVALUE} <p>-</p> SNMP agent SysFanSpeedEX[{#SNMPINDEX}]<p>Update: 60</p><p>LLD</p>
Error $2 on $1 <p>-</p> SNMP agent net.if.err[{#SNMPVALUE},bps]<p>Update: 60</p><p>LLD</p>
Recived $2 on $1 <p>-</p> SNMP agent net.if.in[{#SNMPVALUE}, bps]<p>Update: 60</p><p>LLD</p>
Sent $2 on $1 <p>-</p> SNMP agent net.if.out[{#SNMPVALUE}, bps]<p>Update: 60</p><p>LLD</p>
Capacity of {#SNMPVALUE} <p>-</p> SNMP agent HdCapacityEX[{#SNMPINDEX}]<p>Update: 3600</p><p>LLD</p>
Model of {#SNMPVALUE} <p>-</p> SNMP agent HdModelEX[{#SNMPINDEX}]<p>Update: 3600</p><p>LLD</p>
S.M.A.R.T. info of {#SNMPVALUE} <p>-</p> SNMP agent HdSmartInfoEX[{#SNMPINDEX}]<p>Update: 60</p><p>LLD</p>
Status of {#SNMPVALUE} <p>-</p> SNMP agent HdStatusEX[{#SNMPINDEX}]<p>Update: 60</p><p>LLD</p>
Temperature of {#SNMPVALUE} <p>-</p> SNMP agent HdTemperatureEX[{#SNMPINDEX}]<p>Update: 60</p><p>LLD</p>
Free size of {#SNMPVALUE} <p>-</p> SNMP agent SysVolumeFreeSizeEX[{#SNMPINDEX}]<p>Update: 60</p><p>LLD</p>
Free size of {#SNMPVALUE} (%) <p>-</p> Calculated SysVolumePFreeSizeEX[{#SNMPINDEX}]<p>Update: 60</p><p>LLD</p>
Status of {#SNMPVALUE} <p>-</p> SNMP agent SysVolumeStatusEX[{#SNMPINDEX}]<p>Update: 60</p><p>LLD</p>
Total size of {#SNMPVALUE} <p>-</p> SNMP agent SysVolumeTotalSizeEX[{#SNMPINDEX}]<p>Update: 3600</p><p>LLD</p>

Triggers

Name Description Expression Priority
SMART state of {#SNMPVALUE} on {HOST.NAME} is ABNORMAL <p>Abnormal 1. Any SMART value is equal or less than trhreshold. 2. Hard Disk temperature is higher than 65 degree C. ——– QNAP Knowledgebase</p> <p>Expression: find(/Template SNMP QNAP NAS/HdSmartInfoEX[{#SNMPINDEX}],,”iregexp”,”abnormal”)=1</p><p>Recovery expression: </p> average
SMART state of {#SNMPVALUE} on {HOST.NAME} is not GOOD ({ITEM.VALUE1}) <p>Normal 1. Any Smart value is equal or less than threhold + (initial_SMART_value - threhold)/2. For example, if the initial SMART value is 100, the current value is 50, the threshold is 20, then the Smart value, 50, is less than 20+(100-20)/2. Thus, the health level would be Normal. 2. Any SMART test(Rapid or Complete) result of last 20 times is abnormal. 3. Hard Disk temperature is between 55 to 65 degree C. ——– QNAP Knowledgebase</p> <p>Expression: find(/Template SNMP QNAP NAS/HdSmartInfoEX[{#SNMPINDEX}],,”iregexp”,”normal”)=1</p><p>Recovery expression: </p> warning
State of {#SNMPVALUE} on {HOST.NAME} is “Invalid” <p>State “Invalid”</p> <p>Expression: last(/Template SNMP QNAP NAS/HdStatusEX[{#SNMPINDEX}])=-6</p><p>Recovery expression: </p> warning
State of {#SNMPVALUE} on {HOST.NAME} is “noDisk” <p>State “noDisk”</p> <p>Expression: last(/Template SNMP QNAP NAS/HdStatusEX[{#SNMPINDEX}])=-5</p><p>Recovery expression: </p> information
State of {#SNMPVALUE} on {HOST.NAME} is “rwError” <p>State “rwError”</p> <p>Expression: last(/Template SNMP QNAP NAS/HdStatusEX[{#SNMPINDEX}])=-9</p><p>Recovery expression: </p> warning
State of {#SNMPVALUE} on {HOST.NAME} is not “Ready” ({ITEM.VALUE1}) <p>-</p> <p>Expression: last(/Template SNMP QNAP NAS/HdStatusEX[{#SNMPINDEX}])<>0</p><p>Recovery expression: </p> information
Temperature of {#SNMPVALUE} on {HOST.NAME} is over {$HD_TEMPERATURE_ALARM} for 2 min <p>-</p> <p>Expression: min(/Template SNMP QNAP NAS/HdTemperatureEX[{#SNMPINDEX}],2m)>51</p><p>Recovery expression: </p> high
Temperature of {#SNMPVALUE} on {HOST.NAME} is over {$HD_TEMPERATURE_WARNING} for 2min <p>-</p> <p>Expression: min(/Template SNMP QNAP NAS/HdTemperatureEX[{#SNMPINDEX}],2m)>40</p><p>Recovery expression: </p> information
{#SNMPVALUE} fan on {HOST.NAME} possibly is stopped <p>-</p> <p>Expression: max(/Template SNMP QNAP NAS/SysFanSpeedEX[{#SNMPINDEX}],60s)=0</p><p>Recovery expression: </p> warning
Free space is less than 20% on volume {#SNMPVALUE} <p>-</p> <p>Expression: last(/Template SNMP QNAP NAS/SysVolumePFreeSizeEX[{#SNMPINDEX}])<20</p><p>Recovery expression: </p> warning
{#SNMPVALUE} fan on {HOST.NAME} possibly is stopped (LLD) <p>-</p> <p>Expression: max(/Template SNMP QNAP NAS/SysFanSpeedEX[{#SNMPINDEX}],60s)=0</p><p>Recovery expression: </p> warning
SMART state of {#SNMPVALUE} on {HOST.NAME} is ABNORMAL (LLD) <p>Abnormal 1. Any SMART value is equal or less than trhreshold. 2. Hard Disk temperature is higher than 65 degree C. ——– QNAP Knowledgebase</p> <p>Expression: find(/Template SNMP QNAP NAS/HdSmartInfoEX[{#SNMPINDEX}],,”iregexp”,”abnormal”)=1</p><p>Recovery expression: </p> average
SMART state of {#SNMPVALUE} on {HOST.NAME} is not GOOD ({ITEM.VALUE1}) (LLD) <p>Normal 1. Any Smart value is equal or less than threhold + (initial_SMART_value - threhold)/2. For example, if the initial SMART value is 100, the current value is 50, the threshold is 20, then the Smart value, 50, is less than 20+(100-20)/2. Thus, the health level would be Normal. 2. Any SMART test(Rapid or Complete) result of last 20 times is abnormal. 3. Hard Disk temperature is between 55 to 65 degree C. ——– QNAP Knowledgebase</p> <p>Expression: find(/Template SNMP QNAP NAS/HdSmartInfoEX[{#SNMPINDEX}],,”iregexp”,”normal”)=1</p><p>Recovery expression: </p> warning
State of {#SNMPVALUE} on {HOST.NAME} is “Invalid” (LLD) <p>State “Invalid”</p> <p>Expression: last(/Template SNMP QNAP NAS/HdStatusEX[{#SNMPINDEX}])=-6</p><p>Recovery expression: </p> warning
State of {#SNMPVALUE} on {HOST.NAME} is “noDisk” (LLD) <p>State “noDisk”</p> <p>Expression: last(/Template SNMP QNAP NAS/HdStatusEX[{#SNMPINDEX}])=-5</p><p>Recovery expression: </p> information
State of {#SNMPVALUE} on {HOST.NAME} is “rwError” (LLD) <p>State “rwError”</p> <p>Expression: last(/Template SNMP QNAP NAS/HdStatusEX[{#SNMPINDEX}])=-9</p><p>Recovery expression: </p> warning
State of {#SNMPVALUE} on {HOST.NAME} is not “Ready” ({ITEM.VALUE1}) (LLD) <p>-</p> <p>Expression: last(/Template SNMP QNAP NAS/HdStatusEX[{#SNMPINDEX}])<>0</p><p>Recovery expression: </p> information
Temperature of {#SNMPVALUE} on {HOST.NAME} is over {$HD_TEMPERATURE_ALARM} for 2 min (LLD) <p>-</p> <p>Expression: min(/Template SNMP QNAP NAS/HdTemperatureEX[{#SNMPINDEX}],2m)>51</p><p>Recovery expression: </p> high
Temperature of {#SNMPVALUE} on {HOST.NAME} is over {$HD_TEMPERATURE_WARNING} for 2min (LLD) <p>-</p> <p>Expression: min(/Template SNMP QNAP NAS/HdTemperatureEX[{#SNMPINDEX}],2m)>40</p><p>Recovery expression: </p> information
Free space is less than 20% on volume {#SNMPVALUE} (LLD) <p>-</p> <p>Expression: last(/Template SNMP QNAP NAS/SysVolumePFreeSizeEX[{#SNMPINDEX}])<20</p><p>Recovery expression: </p> warning

Template SNMP QNAP NAS

Macros used

Name Description Default Type
{$HD_TEMPERATURE_ALARM} <p>-</p> 51 Text macro
{$HD_TEMPERATURE_WARNING} <p>-</p> 40 Text macro

There are no template links in this template.

Discovery rules

Name Description Type Key and additional info
System fans discovery <p>-</p> SNMP agent sysFans.discovery<p>Update: 3600</p>
Network interfaces discovery <p>-</p> SNMP agent netIfs.discovery<p>Update: 3600</p>
Hard disks discovery <p>-</p> SNMP agent sysHDs.discovery<p>Update: 3600</p>
Volumes discovery <p>-</p> SNMP agent sysVolumes.discovery<p>Update: 3600</p>

Items collected

Name Description Type Key and additional info
Device model name <p>-</p> SNMP agent ModelNameEX<p>Update: 10800</p>
System total memory <p>-</p> SNMP agent SystemTotalMemEX<p>Update: 10800</p>
Device system name <p>Host name</p> SNMP agent HostNameEX<p>Update: 3600</p>
Device software revision <p>-</p> SNMP agent PhysicalSoftwareRev<p>Update: 3600</p>
CPU temperature <p>CPU temperature in centigrade</p> SNMP agent CPU-TemperatureEX<p>Update: 60</p>
Device hardware revision <p>-</p> SNMP agent PhysicalHardwareRev<p>Update: 10800</p>
CPU usage <p>System CPU usage</p> SNMP agent SystemCPU-UsageEX<p>Update: 60</p>
System free memory (%) <p>-</p> Calculated SystemPFreeMemEX<p>Update: 60</p>
System uptime <p>-</p> SNMP agent sysUptime<p>Update: 60</p>
Device firmware revision <p>-</p> SNMP agent PhysicalFirmwareRev<p>Update: 3600</p>
System temperature <p>System temperature in centigrade</p> SNMP agent SystemTemperatureEX<p>Update: 60</p>
System free memory <p>-</p> SNMP agent SystemFreeMemEX<p>Update: 60</p>
Device vendor name <p>-</p> SNMP agent sysPhysicalMfgName<p>Update: 3600</p>
Speed of {#SNMPVALUE} <p>-</p> SNMP agent SysFanSpeedEX[{#SNMPINDEX}]<p>Update: 60</p><p>LLD</p>
Error $2 on $1 <p>-</p> SNMP agent net.if.err[{#SNMPVALUE},bps]<p>Update: 60</p><p>LLD</p>
Recived $2 on $1 <p>-</p> SNMP agent net.if.in[{#SNMPVALUE}, bps]<p>Update: 60</p><p>LLD</p>
Sent $2 on $1 <p>-</p> SNMP agent net.if.out[{#SNMPVALUE}, bps]<p>Update: 60</p><p>LLD</p>
Capacity of {#SNMPVALUE} <p>-</p> SNMP agent HdCapacityEX[{#SNMPINDEX}]<p>Update: 3600</p><p>LLD</p>
Model of {#SNMPVALUE} <p>-</p> SNMP agent HdModelEX[{#SNMPINDEX}]<p>Update: 3600</p><p>LLD</p>
S.M.A.R.T. info of {#SNMPVALUE} <p>-</p> SNMP agent HdSmartInfoEX[{#SNMPINDEX}]<p>Update: 60</p><p>LLD</p>
Status of {#SNMPVALUE} <p>-</p> SNMP agent HdStatusEX[{#SNMPINDEX}]<p>Update: 60</p><p>LLD</p>
Temperature of {#SNMPVALUE} <p>-</p> SNMP agent HdTemperatureEX[{#SNMPINDEX}]<p>Update: 60</p><p>LLD</p>
Free size of {#SNMPVALUE} <p>-</p> SNMP agent SysVolumeFreeSizeEX[{#SNMPINDEX}]<p>Update: 60</p><p>LLD</p>
Free size of {#SNMPVALUE} (%) <p>-</p> Calculated SysVolumePFreeSizeEX[{#SNMPINDEX}]<p>Update: 60</p><p>LLD</p>
Status of {#SNMPVALUE} <p>-</p> SNMP agent SysVolumeStatusEX[{#SNMPINDEX}]<p>Update: 60</p><p>LLD</p>
Total size of {#SNMPVALUE} <p>-</p> SNMP agent SysVolumeTotalSizeEX[{#SNMPINDEX}]<p>Update: 3600</p><p>LLD</p>

Triggers

Name Description Expression Priority
SMART state of {#SNMPVALUE} on {HOST.NAME} is ABNORMAL <p>Abnormal 1. Any SMART value is equal or less than trhreshold. 2. Hard Disk temperature is higher than 65 degree C. ——– QNAP Knowledgebase</p> <p>Expression: find(/Template SNMP QNAP NAS/HdSmartInfoEX[{#SNMPINDEX}],,”iregexp”,”abnormal”)=1</p><p>Recovery expression: </p> average
SMART state of {#SNMPVALUE} on {HOST.NAME} is not GOOD ({ITEM.VALUE1}) <p>Normal 1. Any Smart value is equal or less than threhold + (initial_SMART_value - threhold)/2. For example, if the initial SMART value is 100, the current value is 50, the threshold is 20, then the Smart value, 50, is less than 20+(100-20)/2. Thus, the health level would be Normal. 2. Any SMART test(Rapid or Complete) result of last 20 times is abnormal. 3. Hard Disk temperature is between 55 to 65 degree C. ——– QNAP Knowledgebase</p> <p>Expression: find(/Template SNMP QNAP NAS/HdSmartInfoEX[{#SNMPINDEX}],,”iregexp”,”normal”)=1</p><p>Recovery expression: </p> warning
State of {#SNMPVALUE} on {HOST.NAME} is “Invalid” <p>State “Invalid”</p> <p>Expression: last(/Template SNMP QNAP NAS/HdStatusEX[{#SNMPINDEX}])=-6</p><p>Recovery expression: </p> warning
State of {#SNMPVALUE} on {HOST.NAME} is “noDisk” <p>State “noDisk”</p> <p>Expression: last(/Template SNMP QNAP NAS/HdStatusEX[{#SNMPINDEX}])=-5</p><p>Recovery expression: </p> information
State of {#SNMPVALUE} on {HOST.NAME} is “rwError” <p>State “rwError”</p> <p>Expression: last(/Template SNMP QNAP NAS/HdStatusEX[{#SNMPINDEX}])=-9</p><p>Recovery expression: </p> warning
State of {#SNMPVALUE} on {HOST.NAME} is not “Ready” ({ITEM.VALUE1}) <p>-</p> <p>Expression: last(/Template SNMP QNAP NAS/HdStatusEX[{#SNMPINDEX}])<>0</p><p>Recovery expression: </p> information
Temperature of {#SNMPVALUE} on {HOST.NAME} is over {$HD_TEMPERATURE_ALARM} for 2 min <p>-</p> <p>Expression: min(/Template SNMP QNAP NAS/HdTemperatureEX[{#SNMPINDEX}],2m)>51</p><p>Recovery expression: </p> high
Temperature of {#SNMPVALUE} on {HOST.NAME} is over {$HD_TEMPERATURE_WARNING} for 2min <p>-</p> <p>Expression: min(/Template SNMP QNAP NAS/HdTemperatureEX[{#SNMPINDEX}],2m)>40</p><p>Recovery expression: </p> information
{#SNMPVALUE} fan on {HOST.NAME} possibly is stopped <p>-</p> <p>Expression: max(/Template SNMP QNAP NAS/SysFanSpeedEX[{#SNMPINDEX}],60s)=0</p><p>Recovery expression: </p> warning
Free space is less than 20% on volume {#SNMPVALUE} <p>-</p> <p>Expression: last(/Template SNMP QNAP NAS/SysVolumePFreeSizeEX[{#SNMPINDEX}])<20</p><p>Recovery expression: </p> warning
{#SNMPVALUE} fan on {HOST.NAME} possibly is stopped (LLD) <p>-</p> <p>Expression: max(/Template SNMP QNAP NAS/SysFanSpeedEX[{#SNMPINDEX}],60s)=0</p><p>Recovery expression: </p> warning
SMART state of {#SNMPVALUE} on {HOST.NAME} is ABNORMAL (LLD) <p>Abnormal 1. Any SMART value is equal or less than trhreshold. 2. Hard Disk temperature is higher than 65 degree C. ——– QNAP Knowledgebase</p> <p>Expression: find(/Template SNMP QNAP NAS/HdSmartInfoEX[{#SNMPINDEX}],,”iregexp”,”abnormal”)=1</p><p>Recovery expression: </p> average
SMART state of {#SNMPVALUE} on {HOST.NAME} is not GOOD ({ITEM.VALUE1}) (LLD) <p>Normal 1. Any Smart value is equal or less than threhold + (initial_SMART_value - threhold)/2. For example, if the initial SMART value is 100, the current value is 50, the threshold is 20, then the Smart value, 50, is less than 20+(100-20)/2. Thus, the health level would be Normal. 2. Any SMART test(Rapid or Complete) result of last 20 times is abnormal. 3. Hard Disk temperature is between 55 to 65 degree C. ——– QNAP Knowledgebase</p> <p>Expression: find(/Template SNMP QNAP NAS/HdSmartInfoEX[{#SNMPINDEX}],,”iregexp”,”normal”)=1</p><p>Recovery expression: </p> warning
State of {#SNMPVALUE} on {HOST.NAME} is “Invalid” (LLD) <p>State “Invalid”</p> <p>Expression: last(/Template SNMP QNAP NAS/HdStatusEX[{#SNMPINDEX}])=-6</p><p>Recovery expression: </p> warning
State of {#SNMPVALUE} on {HOST.NAME} is “noDisk” (LLD) <p>State “noDisk”</p> <p>Expression: last(/Template SNMP QNAP NAS/HdStatusEX[{#SNMPINDEX}])=-5</p><p>Recovery expression: </p> information
State of {#SNMPVALUE} on {HOST.NAME} is “rwError” (LLD) <p>State “rwError”</p> <p>Expression: last(/Template SNMP QNAP NAS/HdStatusEX[{#SNMPINDEX}])=-9</p><p>Recovery expression: </p> warning
State of {#SNMPVALUE} on {HOST.NAME} is not “Ready” ({ITEM.VALUE1}) (LLD) <p>-</p> <p>Expression: last(/Template SNMP QNAP NAS/HdStatusEX[{#SNMPINDEX}])<>0</p><p>Recovery expression: </p> information
Temperature of {#SNMPVALUE} on {HOST.NAME} is over {$HD_TEMPERATURE_ALARM} for 2 min (LLD) <p>-</p> <p>Expression: min(/Template SNMP QNAP NAS/HdTemperatureEX[{#SNMPINDEX}],2m)>51</p><p>Recovery expression: </p> high
Temperature of {#SNMPVALUE} on {HOST.NAME} is over {$HD_TEMPERATURE_WARNING} for 2min (LLD) <p>-</p> <p>Expression: min(/Template SNMP QNAP NAS/HdTemperatureEX[{#SNMPINDEX}],2m)>40</p><p>Recovery expression: </p> information
Free space is less than 20% on volume {#SNMPVALUE} (LLD) <p>-</p> <p>Expression: last(/Template SNMP QNAP NAS/SysVolumePFreeSizeEX[{#SNMPINDEX}])<20</p><p>Recovery expression: </p> warning