Available versions




SNMP-iDRAC-9

Description

Lucas Afonso Kremer https://www.linkedin.com/in/lucasafonsokremer

Overview

Template for Dell servers with iDRAC 9 controller.

{$SNMP_COMMUNITY} with the community to be used

snmpstatus -v 2c -c public 192.168.0.1 Based on @endersonmaia iDRAC 7 template

Author

Lucas Afonso Kremer

Macros used

There are no macros links in this template.

There are no template links in this template.

Discovery rules

Name Description Type Key and additional info
Voltage Table Enumeration <p>-</p> SNMP agent VoltageTable<p>Update: 1d</p>
Processor Enumeration <p>-</p> SNMP agent ProcEnum<p>Update: 1d</p>
Disk Enumeration <p>-</p> SNMP agent DiskEnumeration<p>Update: 1d</p>
Disk Volume Enumeration <p>-</p> SNMP agent VolumeEnum<p>Update: 1d</p>
Temperature Enumeration <p>-</p> SNMP agent TempEnum<p>Update: 1d</p>
Power Supply Enumeration <p>-</p> SNMP agent PowerSupplies<p>Update: 1d</p>
Fan Enumeration <p>-</p> SNMP agent FanEnumeration<p>Update: 1d</p>
Network Enumeration <p>-</p> SNMP agent NetworkEnum<p>Update: 1d</p>
Memory Enumeration <p>-</p> SNMP agent MemoryEnum<p>Update: 1d;50s/1-7,00:00-24:00</p>

Items collected

Name Description Type Key and additional info
Overall System Status <p>-</p> SNMP agent GlobalSystemStatus<p>Update: 5m</p>
Overall System LCD Status <p>-</p> SNMP agent GlobalSystemLCDStatus<p>Update: 1h</p>
Power Usage Minimum Idle Power <p>-</p> SNMP agent PowerUsageMinIdle<p>Update: 1h</p>
BIOS Version <p>-</p> SNMP agent BiosVersion<p>Update: 1d</p>
DRAC version <p>-</p> SNMP agent idrac_version<p>Update: 1d</p>
System Express Service Code <p>-</p> SNMP agent idrac_esc<p>Update: 1d</p>
RAID Controller : Firmware Version <p>-</p> SNMP agent RAIDControllerFirmware<p>Update: 1d</p>
DRAC Firmware version <p>-</p> SNMP agent idrac_firmwareversion<p>Update: 1d</p>
RAID Controller : Name <p>-</p> SNMP agent RAIDControllerName<p>Update: 1d</p>
CMOS Battery Status <p>-</p> SNMP agent CMOSBatteryStatus<p>Update: 1h</p>
System Asset Tag <p>-</p> SNMP agent idrac_assettag<p>Update: 1d</p>
Voltage Status Combined <p>-</p> SNMP agent VoltageStatusCombined<p>Update: 10m</p>
System Model <p>-</p> SNMP agent idrac_SystemModel<p>Update: 1d</p>
System Power State <p>4 server is on 3 server is on stand-by</p> SNMP agent SystemPowerState<p>Update: 5m</p>
Overall System Power State <p>-</p> SNMP agent GlobalSystemPowerState<p>Update: 1h</p>
DRAC Access URL <p>-</p> SNMP agent idrac_acessurl<p>Update: 1d</p>
System BIOS Status <p>-</p> SNMP agent SystemBiosStatus<p>Update: 1h</p>
RAID Controller : Status <p>-</p> SNMP agent RAIDControllerStatus<p>Update: 10m</p>
BIOS Date <p>-</p> SNMP agent BiosDate<p>Update: 1d</p>
Power Usage Sensor Status <p>-</p> SNMP agent PowerUsageSensorStatus<p>Update: 1h</p>
Overall System Storage Status <p>-</p> SNMP agent GlobalSystemStorageStatus<p>Update: 1h</p>
Voltage : {#SNMPVALUE} Status <p>-</p> SNMP agent VoltageStatus.[{#SNMPINDEX}]<p>Update: 10m</p><p>LLD</p>
Processor {#SNMPINDEX} Status <p>-</p> SNMP agent ProcStatus.[{#SNMPINDEX}]<p>Update: 5m</p><p>LLD</p>
Disk {#SNMPINDEX} : Manufacture Day <p>-</p> SNMP agent DiskManufactureDay.[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p>
Disk {#SNMPINDEX} : Manufacturer <p>-</p> SNMP agent DiskManufacturer.[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p>
Disk {#SNMPINDEX} : Manufacture Week <p>-</p> SNMP agent DiskManufactureWeek.[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p>
Disk {#SNMPINDEX} : Manufacture Year <p>-</p> SNMP agent DiskManufactureYear.[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p>
Disk {#SNMPINDEX} : Model Number <p>-</p> SNMP agent DiskModel.[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p>
Disk {#SNMPINDEX} : Name <p>-</p> SNMP agent DiskName.[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p>
Disk {#SNMPINDEX} : Serial Number <p>-</p> SNMP agent DiskSerialNo.[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p>
Disk {#SNMPINDEX} : Disk Size <p>-</p> SNMP agent DiskSize.[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p>
Disk {#SNMPINDEX} : Disk State <p>-</p> SNMP agent DiskState.[{#SNMPINDEX}]<p>Update: 1h</p><p>LLD</p>
Disk {#SNMPINDEX} : Disk Status <p>-</p> SNMP agent DiskStatus.[{#SNMPINDEX}]<p>Update: 1h</p><p>LLD</p>
Volume {#SNMPINDEX} : Virtual Disk State <p>-</p> SNMP agent VolumeDiskState.[{#SNMPINDEX}]<p>Update: 1h</p><p>LLD</p>
Volume {#SNMPINDEX} : Name <p>-</p> SNMP agent VolumeName.[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p>
Volume {#SNMPINDEX} : Size <p>-</p> SNMP agent VolumeSize.[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p>
Volume {#SNMPINDEX} : State <p>-</p> SNMP agent VolumeState.[{#SNMPINDEX}]<p>Update: 1h</p><p>LLD</p>
Volume {#SNMPINDEX} : Status <p>-</p> SNMP agent VolumeStatus.[{#SNMPINDEX}]<p>Update: 1h</p><p>LLD</p>
Temperature Sensor {#SNMPVALUE} Critical Low-Limit <p>-</p> SNMP agent TempCritLowLimit.[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p>
Temperature Sensor {#SNMPVALUE} Critical Up-Limit <p>-</p> SNMP agent TempCritUpLimit.[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p>
Temperature Sensor {#SNMPVALUE} Status <p>-</p> SNMP agent TempStatus.[{#SNMPINDEX}]<p>Update: 5m</p><p>LLD</p>
Temperature Sensor {#SNMPVALUE} Value <p>-</p> SNMP agent TempValue.[{#SNMPINDEX}]<p>Update: 5m</p><p>LLD</p>
Temperature Sensor {#SNMPVALUE} Warning Low-Limit <p>-</p> SNMP agent TempWarnLowLimit.[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p>
Temperature Sensor {#SNMPVALUE} Warning Up-Limit <p>-</p> SNMP agent TempWarnUpLimit.[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p>
Power Supply {#SNMPINDEX} Input Voltage <p>-</p> SNMP agent PowerSupplyInputVoltage.[{#SNMPINDEX}]<p>Update: 5m</p><p>LLD</p>
Power Supply {#SNMPINDEX} Maximum Power <p>-</p> SNMP agent PowerSupplyMaxPower.[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p>
Power Supply {#SNMPINDEX} Sensor State <p>-</p> SNMP agent PowerSupplySensorState.[{#SNMPINDEX}]<p>Update: 10m</p><p>LLD</p>
Power Supply {#SNMPINDEX} State Settings <p>-</p> SNMP agent PowerSupplyStateSettings.[{#SNMPINDEX}]<p>Update: 10m</p><p>LLD</p>
Power Supply {#SNMPINDEX} Status <p>-</p> SNMP agent PowerSupplyStatus.[{#SNMPINDEX}]<p>Update: 5m</p><p>LLD</p>
Fan {#SNMPVALUE} Speed <p>-</p> SNMP agent FanSpeed.[{#SNMPINDEX}]<p>Update: 5m</p><p>LLD</p>
Fan {#SNMPVALUE} Status <p>-</p> SNMP agent FanStatus.[{#SNMPINDEX}]<p>Update: 5m</p><p>LLD</p>
NIC {#SNMPINDEX} : Connection Status <p>-</p> SNMP agent NetConnStatus.[{#SNMPINDEX}]<p>Update: 10m</p><p>LLD</p>
NIC {#SNMPINDEX} : MAC Address <p>-</p> SNMP agent NetMAC.[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p>
NIC {#SNMPINDEX} : Name <p>-</p> SNMP agent NetName.[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p>
NIC {#SNMPINDEX} : Slot <p>-</p> SNMP agent NetSlot.[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p>
NIC {#SNMPINDEX} : Status <p>-</p> SNMP agent NetStatus.[{#SNMPINDEX}]<p>Update: 5m</p><p>LLD</p>
Memory Slot {#SNMPVALUE} Manufacturer <p>-</p> SNMP agent MemManufacturer[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p>
Memory Slot {#SNMPVALUE} Part Number <p>-</p> SNMP agent MemPartlNo.[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p>
Memory Slot {#SNMPVALUE} Serial Number <p>-</p> SNMP agent MemSerialNo.[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p>
Memory Slot {#SNMPVALUE} Size <p>-</p> SNMP agent MemSize.[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p>
Memory Slot {#SNMPVALUE} Speed <p>-</p> SNMP agent MemSpeed.[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p>
Memory Slot {#SNMPVALUE} Status <p>-</p> SNMP agent MemStatus.[{#SNMPINDEX}]<p>Update: 30m</p><p>LLD</p>

Triggers

Name Description Expression Priority
{HOST.NAME}: Problem with Disk {#SNMPINDEX} <p>-</p> <p>Expression: ({SNMP-iDRAC-9:DiskStatus.[{#SNMPINDEX}].last(0)}<>3) and ({SNMP-iDRAC-9:SystemPowerState.last(0)}=4)</p><p>Recovery expression: </p> disaster
{HOST.NAME}: Problem with FAN {#SNMPVALUE} <p>-</p> <p>Expression: ({SNMP-iDRAC-9:FanStatus.[{#SNMPINDEX}].last(0)}<>3) and ({SNMP-iDRAC-9:SystemPowerState.last(0)}=4)</p><p>Recovery expression: </p> average
{HOST.NAME}: Problem with memory in slot {#SNMPVALUE} <p>-</p> <p>Expression: ({SNMP-iDRAC-9:MemStatus.[{#SNMPINDEX}].last(0)}<>3) and ({SNMP-iDRAC-9:SystemPowerState.last(0)}=4)</p><p>Recovery expression: </p> high
{HOST.NAME}: Error on NIC {#SNMPINDEX} <p>-</p> <p>Expression: ({SNMP-iDRAC-9:NetStatus.[{#SNMPINDEX}].last(0)}<>3) and ({SNMP-iDRAC-9:SystemPowerState.last(0)}=4)</p><p>Recovery expression: </p> disaster
{HOST.NAME}: Error on PSU {#SNMPINDEX} State <p>-</p> <p>Expression: ({SNMP-iDRAC-9:PowerSupplySensorState.[{#SNMPINDEX}].last(0)}<>1) and ({SNMP-iDRAC-9:SystemPowerState.last(0)}=4)</p><p>Recovery expression: </p> high
{HOST.NAME}: Problem with PSU {#SNMPINDEX} <p>-</p> <p>Expression: ({SNMP-iDRAC-9:PowerSupplyStatus.[{#SNMPINDEX}].last(0)}<>3) and ({SNMP-iDRAC-9:SystemPowerState.last(0)}=4)</p><p>Recovery expression: </p> high
{HOST.NAME}: Error on Processor {#SNMPINDEX} <p>-</p> <p>Expression: ({SNMP-iDRAC-9:ProcStatus.[{#SNMPINDEX}].last(0)}<>3) and ({SNMP-iDRAC-9:ProcStatus.[{#SNMPINDEX}].last(0)}<>2) and ({SNMP-iDRAC-9:SystemPowerState.last(0)}=4)</p><p>Recovery expression: </p> disaster
Problem with Temperature Sensor {#SNMPVALUE} <p>-</p> <p>Expression: {SNMP-iDRAC-9:TempStatus.[{#SNMPINDEX}].last(0)}<>3</p><p>Recovery expression: </p> warning
Temperature on {#SNMPVALUE} critically high <p>Temperature of the item is above Critical Level.</p> <p>Expression: {SNMP-iDRAC-9:TempValue.[{#SNMPINDEX}].last()} >= {SNMP-iDRAC-9:TempCritUpLimit.[{#SNMPINDEX}].last()}</p><p>Recovery expression: </p> high
Temperature on {#SNMPVALUE} critically low <p>Temperature of the item is below Critical Level.</p> <p>Expression: {SNMP-iDRAC-9:TempValue.[{#SNMPINDEX}].last()} <= {SNMP-iDRAC-9:TempCritLowLimit.[{#SNMPINDEX}].last()}</p><p>Recovery expression: </p> high
Temperature on {#SNMPVALUE} to high <p>Temperature of the item is above Warning Level.</p> <p>Expression: {SNMP-iDRAC-9:TempValue.[{#SNMPINDEX}].last()} > {SNMP-iDRAC-9:TempWarnUpLimit.[{#SNMPINDEX}].last()} and {SNMP-iDRAC-9:TempValue.[{#SNMPINDEX}].last()} < {SNMP-iDRAC-9:TempCritUpLimit.[{#SNMPINDEX}].last()}</p><p>Recovery expression: </p> warning
Temperature on {#SNMPVALUE} to low <p>Temperature of the item is below Warning Level.</p> <p>Expression: {SNMP-iDRAC-9:TempValue.[{#SNMPINDEX}].last()} < {SNMP-iDRAC-9:TempWarnLowLimit.[{#SNMPINDEX}].last()} and {SNMP-iDRAC-9:TempValue.[{#SNMPINDEX}].last()} > {SNMP-iDRAC-9:TempCritLowLimit.[{#SNMPINDEX}].last()}</p><p>Recovery expression: </p> warning
{HOST.NAME}: Error on Voltage Sensor {#SNMPVALUE} <p>-</p> <p>Expression: ({SNMP-iDRAC-9:VoltageStatus.[{#SNMPINDEX}].last(0)}<>3) and ({SNMP-iDRAC-9:SystemPowerState.last(0)}=4)</p><p>Recovery expression: </p> average
{HOST.NAME}: Volume {#SNMPINDEX} Error <p>-</p> <p>Expression: ({SNMP-iDRAC-9:VolumeDiskState.[{#SNMPINDEX}].last(0)}<>2) and ({SNMP-iDRAC-9:SystemPowerState.last(0)}=4)</p><p>Recovery expression: </p> high
{HOST.NAME}: Volume {#SNMPINDEX} Status Error <p>-</p> <p>Expression: ({SNMP-iDRAC-9:VolumeStatus.[{#SNMPINDEX}].last(0)}<>3) and ({SNMP-iDRAC-9:SystemPowerState.last(0)}=4)</p><p>Recovery expression: </p> high
{HOST.NAME}: Error on Voltage Sensor {#SNMPVALUE} (LLD) <p>-</p> <p>Expression: ({SNMP-iDRAC-9:VoltageStatus.[{#SNMPINDEX}].last(0)}<>3) and ({SNMP-iDRAC-9:SystemPowerState.last(0)}=4)</p><p>Recovery expression: </p> average
{HOST.NAME}: Error on Processor {#SNMPINDEX} (LLD) <p>-</p> <p>Expression: ({SNMP-iDRAC-9:ProcStatus.[{#SNMPINDEX}].last(0)}<>3) and ({SNMP-iDRAC-9:ProcStatus.[{#SNMPINDEX}].last(0)}<>2) and ({SNMP-iDRAC-9:SystemPowerState.last(0)}=4)</p><p>Recovery expression: </p> disaster
{HOST.NAME}: Problem with Disk {#SNMPINDEX} (LLD) <p>-</p> <p>Expression: ({SNMP-iDRAC-9:DiskStatus.[{#SNMPINDEX}].last(0)}<>3) and ({SNMP-iDRAC-9:SystemPowerState.last(0)}=4)</p><p>Recovery expression: </p> disaster
{HOST.NAME}: Volume {#SNMPINDEX} Error (LLD) <p>-</p> <p>Expression: ({SNMP-iDRAC-9:VolumeDiskState.[{#SNMPINDEX}].last(0)}<>2) and ({SNMP-iDRAC-9:SystemPowerState.last(0)}=4)</p><p>Recovery expression: </p> high
{HOST.NAME}: Volume {#SNMPINDEX} Status Error (LLD) <p>-</p> <p>Expression: ({SNMP-iDRAC-9:VolumeStatus.[{#SNMPINDEX}].last(0)}<>3) and ({SNMP-iDRAC-9:SystemPowerState.last(0)}=4)</p><p>Recovery expression: </p> high
Problem with Temperature Sensor {#SNMPVALUE} (LLD) <p>-</p> <p>Expression: {SNMP-iDRAC-9:TempStatus.[{#SNMPINDEX}].last(0)}<>3</p><p>Recovery expression: </p> warning
Temperature on {#SNMPVALUE} critically high (LLD) <p>Temperature of the item is above Critical Level.</p> <p>Expression: {SNMP-iDRAC-9:TempValue.[{#SNMPINDEX}].last()} >= {SNMP-iDRAC-9:TempCritUpLimit.[{#SNMPINDEX}].last()}</p><p>Recovery expression: </p> high
Temperature on {#SNMPVALUE} critically low (LLD) <p>Temperature of the item is below Critical Level.</p> <p>Expression: {SNMP-iDRAC-9:TempValue.[{#SNMPINDEX}].last()} <= {SNMP-iDRAC-9:TempCritLowLimit.[{#SNMPINDEX}].last()}</p><p>Recovery expression: </p> high
Temperature on {#SNMPVALUE} to high (LLD) <p>Temperature of the item is above Warning Level.</p> <p>Expression: {SNMP-iDRAC-9:TempValue.[{#SNMPINDEX}].last()} > {SNMP-iDRAC-9:TempWarnUpLimit.[{#SNMPINDEX}].last()} and {SNMP-iDRAC-9:TempValue.[{#SNMPINDEX}].last()} < {SNMP-iDRAC-9:TempCritUpLimit.[{#SNMPINDEX}].last()}</p><p>Recovery expression: </p> warning
Temperature on {#SNMPVALUE} to low (LLD) <p>Temperature of the item is below Warning Level.</p> <p>Expression: {SNMP-iDRAC-9:TempValue.[{#SNMPINDEX}].last()} < {SNMP-iDRAC-9:TempWarnLowLimit.[{#SNMPINDEX}].last()} and {SNMP-iDRAC-9:TempValue.[{#SNMPINDEX}].last()} > {SNMP-iDRAC-9:TempCritLowLimit.[{#SNMPINDEX}].last()}</p><p>Recovery expression: </p> warning
{HOST.NAME}: Error on PSU {#SNMPINDEX} State (LLD) <p>-</p> <p>Expression: ({SNMP-iDRAC-9:PowerSupplySensorState.[{#SNMPINDEX}].last(0)}<>1) and ({SNMP-iDRAC-9:SystemPowerState.last(0)}=4)</p><p>Recovery expression: </p> high
{HOST.NAME}: Problem with PSU {#SNMPINDEX} (LLD) <p>-</p> <p>Expression: ({SNMP-iDRAC-9:PowerSupplyStatus.[{#SNMPINDEX}].last(0)}<>3) and ({SNMP-iDRAC-9:SystemPowerState.last(0)}=4)</p><p>Recovery expression: </p> high
{HOST.NAME}: Problem with FAN {#SNMPVALUE} (LLD) <p>-</p> <p>Expression: ({SNMP-iDRAC-9:FanStatus.[{#SNMPINDEX}].last(0)}<>3) and ({SNMP-iDRAC-9:SystemPowerState.last(0)}=4)</p><p>Recovery expression: </p> average
{HOST.NAME}: Error on NIC {#SNMPINDEX} (LLD) <p>-</p> <p>Expression: ({SNMP-iDRAC-9:NetStatus.[{#SNMPINDEX}].last(0)}<>3) and ({SNMP-iDRAC-9:SystemPowerState.last(0)}=4)</p><p>Recovery expression: </p> disaster
{HOST.NAME}: Problem with memory in slot {#SNMPVALUE} (LLD) <p>-</p> <p>Expression: ({SNMP-iDRAC-9:MemStatus.[{#SNMPINDEX}].last(0)}<>3) and ({SNMP-iDRAC-9:SystemPowerState.last(0)}=4)</p><p>Recovery expression: </p> high

SNMP-iDRAC-9

Description

Lucas Afonso Kremer https://www.linkedin.com/in/lucasafonsokremer

Overview

Template for Dell servers with iDRAC 9 controller.

{$SNMP_COMMUNITY} with the community to be used

snmpstatus -v 2c -c public 192.168.0.1 Based on @endersonmaia iDRAC 7 template

Author

Lucas Afonso Kremer

Macros used

There are no macros links in this template.

There are no template links in this template.

Discovery rules

Name Description Type Key and additional info
Voltage Table Enumeration <p>-</p> SNMP agent VoltageTable<p>Update: 1d</p>
Disk Enumeration <p>-</p> SNMP agent DiskEnumeration<p>Update: 1d</p>
Memory Enumeration <p>-</p> SNMP agent MemoryEnum<p>Update: 1d;50s/1-7,00:00-24:00</p>
Network Enumeration <p>-</p> SNMP agent NetworkEnum<p>Update: 1d</p>
Processor Enumeration <p>-</p> SNMP agent ProcEnum<p>Update: 1d</p>
Fan Enumeration <p>-</p> SNMP agent FanEnumeration<p>Update: 1d</p>
Temperature Enumeration <p>-</p> SNMP agent TempEnum<p>Update: 1d</p>
Disk Volume Enumeration <p>-</p> SNMP agent VolumeEnum<p>Update: 1d</p>
Power Supply Enumeration <p>-</p> SNMP agent PowerSupplies<p>Update: 1d</p>

Items collected

Name Description Type Key and additional info
DRAC Access URL <p>-</p> SNMP agent idrac_acessurl<p>Update: 1d</p>
RAID Controller : Name <p>-</p> SNMP agent RAIDControllerName<p>Update: 1d</p>
System Express Service Code <p>-</p> SNMP agent idrac_esc<p>Update: 1d</p>
Voltage Status Combined <p>-</p> SNMP agent VoltageStatusCombined<p>Update: 10m</p>
Overall System Power State <p>-</p> SNMP agent GlobalSystemPowerState<p>Update: 1h</p>
RAID Controller : Firmware Version <p>-</p> SNMP agent RAIDControllerFirmware<p>Update: 1d</p>
CMOS Battery Status <p>-</p> SNMP agent CMOSBatteryStatus<p>Update: 1h</p>
RAID Controller : Status <p>-</p> SNMP agent RAIDControllerStatus<p>Update: 10m</p>
BIOS Date <p>-</p> SNMP agent BiosDate<p>Update: 1d</p>
DRAC version <p>-</p> SNMP agent idrac_version<p>Update: 1d</p>
System BIOS Status <p>-</p> SNMP agent SystemBiosStatus<p>Update: 1h</p>
System Power State <p>4 server is on 3 server is on stand-by</p> SNMP agent SystemPowerState<p>Update: 5m</p>
Overall System LCD Status <p>-</p> SNMP agent GlobalSystemLCDStatus<p>Update: 1h</p>
Power Usage Minimum Idle Power <p>-</p> SNMP agent PowerUsageMinIdle<p>Update: 1h</p>
Overall System Storage Status <p>-</p> SNMP agent GlobalSystemStorageStatus<p>Update: 1h</p>
System Model <p>-</p> SNMP agent idrac_SystemModel<p>Update: 1d</p>
Overall System Status <p>-</p> SNMP agent GlobalSystemStatus<p>Update: 5m</p>
System Asset Tag <p>-</p> SNMP agent idrac_assettag<p>Update: 1d</p>
Power Usage Sensor Status <p>-</p> SNMP agent PowerUsageSensorStatus<p>Update: 1h</p>
BIOS Version <p>-</p> SNMP agent BiosVersion<p>Update: 1d</p>
DRAC Firmware version <p>-</p> SNMP agent idrac_firmwareversion<p>Update: 1d</p>
Voltage : {#SNMPVALUE} Status <p>-</p> SNMP agent VoltageStatus.[{#SNMPINDEX}]<p>Update: 10m</p><p>LLD</p>
Disk {#SNMPINDEX} : Manufacture Day <p>-</p> SNMP agent DiskManufactureDay.[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p>
Disk {#SNMPINDEX} : Manufacturer <p>-</p> SNMP agent DiskManufacturer.[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p>
Disk {#SNMPINDEX} : Manufacture Week <p>-</p> SNMP agent DiskManufactureWeek.[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p>
Disk {#SNMPINDEX} : Manufacture Year <p>-</p> SNMP agent DiskManufactureYear.[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p>
Disk {#SNMPINDEX} : Model Number <p>-</p> SNMP agent DiskModel.[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p>
Disk {#SNMPINDEX} : Name <p>-</p> SNMP agent DiskName.[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p>
Disk {#SNMPINDEX} : Serial Number <p>-</p> SNMP agent DiskSerialNo.[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p>
Disk {#SNMPINDEX} : Disk Size <p>-</p> SNMP agent DiskSize.[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p>
Disk {#SNMPINDEX} : Disk State <p>-</p> SNMP agent DiskState.[{#SNMPINDEX}]<p>Update: 1h</p><p>LLD</p>
Disk {#SNMPINDEX} : Disk Status <p>-</p> SNMP agent DiskStatus.[{#SNMPINDEX}]<p>Update: 1h</p><p>LLD</p>
Memory Slot {#SNMPVALUE} Manufacturer <p>-</p> SNMP agent MemManufacturer[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p>
Memory Slot {#SNMPVALUE} Part Number <p>-</p> SNMP agent MemPartlNo.[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p>
Memory Slot {#SNMPVALUE} Serial Number <p>-</p> SNMP agent MemSerialNo.[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p>
Memory Slot {#SNMPVALUE} Size <p>-</p> SNMP agent MemSize.[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p>
Memory Slot {#SNMPVALUE} Speed <p>-</p> SNMP agent MemSpeed.[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p>
Memory Slot {#SNMPVALUE} Status <p>-</p> SNMP agent MemStatus.[{#SNMPINDEX}]<p>Update: 30m</p><p>LLD</p>
NIC {#SNMPINDEX} : Connection Status <p>-</p> SNMP agent NetConnStatus.[{#SNMPINDEX}]<p>Update: 10m</p><p>LLD</p>
NIC {#SNMPINDEX} : MAC Address <p>-</p> SNMP agent NetMAC.[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p>
NIC {#SNMPINDEX} : Name <p>-</p> SNMP agent NetName.[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p>
NIC {#SNMPINDEX} : Slot <p>-</p> SNMP agent NetSlot.[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p>
NIC {#SNMPINDEX} : Status <p>-</p> SNMP agent NetStatus.[{#SNMPINDEX}]<p>Update: 5m</p><p>LLD</p>
Processor {#SNMPINDEX} Status <p>-</p> SNMP agent ProcStatus.[{#SNMPINDEX}]<p>Update: 5m</p><p>LLD</p>
Fan {#SNMPVALUE} Speed <p>-</p> SNMP agent FanSpeed.[{#SNMPINDEX}]<p>Update: 5m</p><p>LLD</p>
Fan {#SNMPVALUE} Status <p>-</p> SNMP agent FanStatus.[{#SNMPINDEX}]<p>Update: 5m</p><p>LLD</p>
Temperature Sensor {#SNMPVALUE} Critical Low-Limit <p>-</p> SNMP agent TempCritLowLimit.[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p>
Temperature Sensor {#SNMPVALUE} Critical Up-Limit <p>-</p> SNMP agent TempCritUpLimit.[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p>
Temperature Sensor {#SNMPVALUE} Status <p>-</p> SNMP agent TempStatus.[{#SNMPINDEX}]<p>Update: 5m</p><p>LLD</p>
Temperature Sensor {#SNMPVALUE} Value <p>-</p> SNMP agent TempValue.[{#SNMPINDEX}]<p>Update: 5m</p><p>LLD</p>
Temperature Sensor {#SNMPVALUE} Warning Low-Limit <p>-</p> SNMP agent TempWarnLowLimit.[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p>
Temperature Sensor {#SNMPVALUE} Warning Up-Limit <p>-</p> SNMP agent TempWarnUpLimit.[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p>
Volume {#SNMPINDEX} : Virtual Disk State <p>-</p> SNMP agent VolumeDiskState.[{#SNMPINDEX}]<p>Update: 1h</p><p>LLD</p>
Volume {#SNMPINDEX} : Name <p>-</p> SNMP agent VolumeName.[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p>
Volume {#SNMPINDEX} : Size <p>-</p> SNMP agent VolumeSize.[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p>
Volume {#SNMPINDEX} : State <p>-</p> SNMP agent VolumeState.[{#SNMPINDEX}]<p>Update: 1h</p><p>LLD</p>
Volume {#SNMPINDEX} : Status <p>-</p> SNMP agent VolumeStatus.[{#SNMPINDEX}]<p>Update: 1h</p><p>LLD</p>
Power Supply {#SNMPINDEX} Input Voltage <p>-</p> SNMP agent PowerSupplyInputVoltage.[{#SNMPINDEX}]<p>Update: 5m</p><p>LLD</p>
Power Supply {#SNMPINDEX} Maximum Power <p>-</p> SNMP agent PowerSupplyMaxPower.[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p>
Power Supply {#SNMPINDEX} Sensor State <p>-</p> SNMP agent PowerSupplySensorState.[{#SNMPINDEX}]<p>Update: 10m</p><p>LLD</p>
Power Supply {#SNMPINDEX} State Settings <p>-</p> SNMP agent PowerSupplyStateSettings.[{#SNMPINDEX}]<p>Update: 10m</p><p>LLD</p>
Power Supply {#SNMPINDEX} Status <p>-</p> SNMP agent PowerSupplyStatus.[{#SNMPINDEX}]<p>Update: 5m</p><p>LLD</p>

Triggers

Name Description Expression Priority
{HOST.NAME}: Problem with Disk {#SNMPINDEX} <p>-</p> <p>Expression: (last(/SNMP-iDRAC-9/DiskStatus.[{#SNMPINDEX}])<>3) and (last(/SNMP-iDRAC-9/SystemPowerState)=4)</p><p>Recovery expression: </p> disaster
{HOST.NAME}: Problem with FAN {#SNMPVALUE} <p>-</p> <p>Expression: (last(/SNMP-iDRAC-9/FanStatus.[{#SNMPINDEX}])<>3) and (last(/SNMP-iDRAC-9/SystemPowerState)=4)</p><p>Recovery expression: </p> average
{HOST.NAME}: Problem with memory in slot {#SNMPVALUE} <p>-</p> <p>Expression: (last(/SNMP-iDRAC-9/MemStatus.[{#SNMPINDEX}])<>3) and (last(/SNMP-iDRAC-9/SystemPowerState)=4)</p><p>Recovery expression: </p> high
{HOST.NAME}: Error on NIC {#SNMPINDEX} <p>-</p> <p>Expression: (last(/SNMP-iDRAC-9/NetStatus.[{#SNMPINDEX}])<>3) and (last(/SNMP-iDRAC-9/SystemPowerState)=4)</p><p>Recovery expression: </p> disaster
{HOST.NAME}: Error on PSU {#SNMPINDEX} State <p>-</p> <p>Expression: (last(/SNMP-iDRAC-9/PowerSupplySensorState.[{#SNMPINDEX}])<>1) and (last(/SNMP-iDRAC-9/SystemPowerState)=4)</p><p>Recovery expression: </p> high
{HOST.NAME}: Problem with PSU {#SNMPINDEX} <p>-</p> <p>Expression: (last(/SNMP-iDRAC-9/PowerSupplyStatus.[{#SNMPINDEX}])<>3) and (last(/SNMP-iDRAC-9/SystemPowerState)=4)</p><p>Recovery expression: </p> high
{HOST.NAME}: Error on Processor {#SNMPINDEX} <p>-</p> <p>Expression: (last(/SNMP-iDRAC-9/ProcStatus.[{#SNMPINDEX}])<>3) and (last(/SNMP-iDRAC-9/ProcStatus.[{#SNMPINDEX}])<>2) and (last(/SNMP-iDRAC-9/SystemPowerState)=4)</p><p>Recovery expression: </p> disaster
Problem with Temperature Sensor {#SNMPVALUE} <p>-</p> <p>Expression: last(/SNMP-iDRAC-9/TempStatus.[{#SNMPINDEX}])<>3</p><p>Recovery expression: </p> warning
Temperature on {#SNMPVALUE} critically high <p>Temperature of the item is above Critical Level.</p> <p>Expression: last(/SNMP-iDRAC-9/TempValue.[{#SNMPINDEX}]) >= last(/SNMP-iDRAC-9/TempCritUpLimit.[{#SNMPINDEX}])</p><p>Recovery expression: </p> high
Temperature on {#SNMPVALUE} critically low <p>Temperature of the item is below Critical Level.</p> <p>Expression: last(/SNMP-iDRAC-9/TempValue.[{#SNMPINDEX}]) <= last(/SNMP-iDRAC-9/TempCritLowLimit.[{#SNMPINDEX}])</p><p>Recovery expression: </p> high
Temperature on {#SNMPVALUE} to high <p>Temperature of the item is above Warning Level.</p> <p>Expression: last(/SNMP-iDRAC-9/TempValue.[{#SNMPINDEX}]) > last(/SNMP-iDRAC-9/TempWarnUpLimit.[{#SNMPINDEX}]) and last(/SNMP-iDRAC-9/TempValue.[{#SNMPINDEX}]) < last(/SNMP-iDRAC-9/TempCritUpLimit.[{#SNMPINDEX}])</p><p>Recovery expression: </p> warning
Temperature on {#SNMPVALUE} to low <p>Temperature of the item is below Warning Level.</p> <p>Expression: last(/SNMP-iDRAC-9/TempValue.[{#SNMPINDEX}]) < last(/SNMP-iDRAC-9/TempWarnLowLimit.[{#SNMPINDEX}]) and last(/SNMP-iDRAC-9/TempValue.[{#SNMPINDEX}]) > last(/SNMP-iDRAC-9/TempCritLowLimit.[{#SNMPINDEX}])</p><p>Recovery expression: </p> warning
{HOST.NAME}: Error on Voltage Sensor {#SNMPVALUE} <p>-</p> <p>Expression: (last(/SNMP-iDRAC-9/VoltageStatus.[{#SNMPINDEX}])<>3) and (last(/SNMP-iDRAC-9/SystemPowerState)=4)</p><p>Recovery expression: </p> average
{HOST.NAME}: Volume {#SNMPINDEX} Error <p>-</p> <p>Expression: (last(/SNMP-iDRAC-9/VolumeDiskState.[{#SNMPINDEX}])<>2) and (last(/SNMP-iDRAC-9/SystemPowerState)=4)</p><p>Recovery expression: </p> high
{HOST.NAME}: Volume {#SNMPINDEX} Status Error <p>-</p> <p>Expression: (last(/SNMP-iDRAC-9/VolumeStatus.[{#SNMPINDEX}])<>3) and (last(/SNMP-iDRAC-9/SystemPowerState)=4)</p><p>Recovery expression: </p> high
{HOST.NAME}: Error on Voltage Sensor {#SNMPVALUE} (LLD) <p>-</p> <p>Expression: (last(/SNMP-iDRAC-9/VoltageStatus.[{#SNMPINDEX}])<>3) and (last(/SNMP-iDRAC-9/SystemPowerState)=4)</p><p>Recovery expression: </p> average
{HOST.NAME}: Problem with Disk {#SNMPINDEX} (LLD) <p>-</p> <p>Expression: (last(/SNMP-iDRAC-9/DiskStatus.[{#SNMPINDEX}])<>3) and (last(/SNMP-iDRAC-9/SystemPowerState)=4)</p><p>Recovery expression: </p> disaster
{HOST.NAME}: Problem with memory in slot {#SNMPVALUE} (LLD) <p>-</p> <p>Expression: (last(/SNMP-iDRAC-9/MemStatus.[{#SNMPINDEX}])<>3) and (last(/SNMP-iDRAC-9/SystemPowerState)=4)</p><p>Recovery expression: </p> high
{HOST.NAME}: Error on NIC {#SNMPINDEX} (LLD) <p>-</p> <p>Expression: (last(/SNMP-iDRAC-9/NetStatus.[{#SNMPINDEX}])<>3) and (last(/SNMP-iDRAC-9/SystemPowerState)=4)</p><p>Recovery expression: </p> disaster
{HOST.NAME}: Error on Processor {#SNMPINDEX} (LLD) <p>-</p> <p>Expression: (last(/SNMP-iDRAC-9/ProcStatus.[{#SNMPINDEX}])<>3) and (last(/SNMP-iDRAC-9/ProcStatus.[{#SNMPINDEX}])<>2) and (last(/SNMP-iDRAC-9/SystemPowerState)=4)</p><p>Recovery expression: </p> disaster
{HOST.NAME}: Problem with FAN {#SNMPVALUE} (LLD) <p>-</p> <p>Expression: (last(/SNMP-iDRAC-9/FanStatus.[{#SNMPINDEX}])<>3) and (last(/SNMP-iDRAC-9/SystemPowerState)=4)</p><p>Recovery expression: </p> average
Problem with Temperature Sensor {#SNMPVALUE} (LLD) <p>-</p> <p>Expression: last(/SNMP-iDRAC-9/TempStatus.[{#SNMPINDEX}])<>3</p><p>Recovery expression: </p> warning
Temperature on {#SNMPVALUE} critically high (LLD) <p>Temperature of the item is above Critical Level.</p> <p>Expression: last(/SNMP-iDRAC-9/TempValue.[{#SNMPINDEX}]) >= last(/SNMP-iDRAC-9/TempCritUpLimit.[{#SNMPINDEX}])</p><p>Recovery expression: </p> high
Temperature on {#SNMPVALUE} critically low (LLD) <p>Temperature of the item is below Critical Level.</p> <p>Expression: last(/SNMP-iDRAC-9/TempValue.[{#SNMPINDEX}]) <= last(/SNMP-iDRAC-9/TempCritLowLimit.[{#SNMPINDEX}])</p><p>Recovery expression: </p> high
Temperature on {#SNMPVALUE} to high (LLD) <p>Temperature of the item is above Warning Level.</p> <p>Expression: last(/SNMP-iDRAC-9/TempValue.[{#SNMPINDEX}]) > last(/SNMP-iDRAC-9/TempWarnUpLimit.[{#SNMPINDEX}]) and last(/SNMP-iDRAC-9/TempValue.[{#SNMPINDEX}]) < last(/SNMP-iDRAC-9/TempCritUpLimit.[{#SNMPINDEX}])</p><p>Recovery expression: </p> warning
Temperature on {#SNMPVALUE} to low (LLD) <p>Temperature of the item is below Warning Level.</p> <p>Expression: last(/SNMP-iDRAC-9/TempValue.[{#SNMPINDEX}]) < last(/SNMP-iDRAC-9/TempWarnLowLimit.[{#SNMPINDEX}]) and last(/SNMP-iDRAC-9/TempValue.[{#SNMPINDEX}]) > last(/SNMP-iDRAC-9/TempCritLowLimit.[{#SNMPINDEX}])</p><p>Recovery expression: </p> warning
{HOST.NAME}: Volume {#SNMPINDEX} Error (LLD) <p>-</p> <p>Expression: (last(/SNMP-iDRAC-9/VolumeDiskState.[{#SNMPINDEX}])<>2) and (last(/SNMP-iDRAC-9/SystemPowerState)=4)</p><p>Recovery expression: </p> high
{HOST.NAME}: Volume {#SNMPINDEX} Status Error (LLD) <p>-</p> <p>Expression: (last(/SNMP-iDRAC-9/VolumeStatus.[{#SNMPINDEX}])<>3) and (last(/SNMP-iDRAC-9/SystemPowerState)=4)</p><p>Recovery expression: </p> high
{HOST.NAME}: Error on PSU {#SNMPINDEX} State (LLD) <p>-</p> <p>Expression: (last(/SNMP-iDRAC-9/PowerSupplySensorState.[{#SNMPINDEX}])<>1) and (last(/SNMP-iDRAC-9/SystemPowerState)=4)</p><p>Recovery expression: </p> high
{HOST.NAME}: Problem with PSU {#SNMPINDEX} (LLD) <p>-</p> <p>Expression: (last(/SNMP-iDRAC-9/PowerSupplyStatus.[{#SNMPINDEX}])<>3) and (last(/SNMP-iDRAC-9/SystemPowerState)=4)</p><p>Recovery expression: </p> high

SNMP-iDRAC-9

Description

Lucas Afonso Kremer https://www.linkedin.com/in/lucasafonsokremer

Overview

Template for Dell servers with iDRAC 9 controller.

{$SNMP_COMMUNITY} with the community to be used

snmpstatus -v 2c -c public 192.168.0.1 Based on @endersonmaia iDRAC 7 template

Author

Lucas Afonso Kremer

Macros used

There are no macros links in this template.

There are no template links in this template.

Discovery rules

Name Description Type Key and additional info
Voltage Table Enumeration <p>-</p> SNMP agent VoltageTable<p>Update: 1d</p>
Disk Enumeration <p>-</p> SNMP agent DiskEnumeration<p>Update: 1d</p>
Memory Enumeration <p>-</p> SNMP agent MemoryEnum<p>Update: 1d;50s/1-7,00:00-24:00</p>
Network Enumeration <p>-</p> SNMP agent NetworkEnum<p>Update: 1d</p>
Processor Enumeration <p>-</p> SNMP agent ProcEnum<p>Update: 1d</p>
Fan Enumeration <p>-</p> SNMP agent FanEnumeration<p>Update: 1d</p>
Temperature Enumeration <p>-</p> SNMP agent TempEnum<p>Update: 1d</p>
Disk Volume Enumeration <p>-</p> SNMP agent VolumeEnum<p>Update: 1d</p>
Power Supply Enumeration <p>-</p> SNMP agent PowerSupplies<p>Update: 1d</p>

Items collected

Name Description Type Key and additional info
DRAC Access URL <p>-</p> SNMP agent idrac_acessurl<p>Update: 1d</p>
RAID Controller : Name <p>-</p> SNMP agent RAIDControllerName<p>Update: 1d</p>
System Express Service Code <p>-</p> SNMP agent idrac_esc<p>Update: 1d</p>
Voltage Status Combined <p>-</p> SNMP agent VoltageStatusCombined<p>Update: 10m</p>
Overall System Power State <p>-</p> SNMP agent GlobalSystemPowerState<p>Update: 1h</p>
RAID Controller : Firmware Version <p>-</p> SNMP agent RAIDControllerFirmware<p>Update: 1d</p>
CMOS Battery Status <p>-</p> SNMP agent CMOSBatteryStatus<p>Update: 1h</p>
RAID Controller : Status <p>-</p> SNMP agent RAIDControllerStatus<p>Update: 10m</p>
BIOS Date <p>-</p> SNMP agent BiosDate<p>Update: 1d</p>
DRAC version <p>-</p> SNMP agent idrac_version<p>Update: 1d</p>
System BIOS Status <p>-</p> SNMP agent SystemBiosStatus<p>Update: 1h</p>
System Power State <p>4 server is on 3 server is on stand-by</p> SNMP agent SystemPowerState<p>Update: 5m</p>
Overall System LCD Status <p>-</p> SNMP agent GlobalSystemLCDStatus<p>Update: 1h</p>
Power Usage Minimum Idle Power <p>-</p> SNMP agent PowerUsageMinIdle<p>Update: 1h</p>
Overall System Storage Status <p>-</p> SNMP agent GlobalSystemStorageStatus<p>Update: 1h</p>
System Model <p>-</p> SNMP agent idrac_SystemModel<p>Update: 1d</p>
Overall System Status <p>-</p> SNMP agent GlobalSystemStatus<p>Update: 5m</p>
System Asset Tag <p>-</p> SNMP agent idrac_assettag<p>Update: 1d</p>
Power Usage Sensor Status <p>-</p> SNMP agent PowerUsageSensorStatus<p>Update: 1h</p>
BIOS Version <p>-</p> SNMP agent BiosVersion<p>Update: 1d</p>
DRAC Firmware version <p>-</p> SNMP agent idrac_firmwareversion<p>Update: 1d</p>
Voltage : {#SNMPVALUE} Status <p>-</p> SNMP agent VoltageStatus.[{#SNMPINDEX}]<p>Update: 10m</p><p>LLD</p>
Disk {#SNMPINDEX} : Manufacture Day <p>-</p> SNMP agent DiskManufactureDay.[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p>
Disk {#SNMPINDEX} : Manufacturer <p>-</p> SNMP agent DiskManufacturer.[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p>
Disk {#SNMPINDEX} : Manufacture Week <p>-</p> SNMP agent DiskManufactureWeek.[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p>
Disk {#SNMPINDEX} : Manufacture Year <p>-</p> SNMP agent DiskManufactureYear.[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p>
Disk {#SNMPINDEX} : Model Number <p>-</p> SNMP agent DiskModel.[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p>
Disk {#SNMPINDEX} : Name <p>-</p> SNMP agent DiskName.[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p>
Disk {#SNMPINDEX} : Serial Number <p>-</p> SNMP agent DiskSerialNo.[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p>
Disk {#SNMPINDEX} : Disk Size <p>-</p> SNMP agent DiskSize.[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p>
Disk {#SNMPINDEX} : Disk State <p>-</p> SNMP agent DiskState.[{#SNMPINDEX}]<p>Update: 1h</p><p>LLD</p>
Disk {#SNMPINDEX} : Disk Status <p>-</p> SNMP agent DiskStatus.[{#SNMPINDEX}]<p>Update: 1h</p><p>LLD</p>
Memory Slot {#SNMPVALUE} Manufacturer <p>-</p> SNMP agent MemManufacturer[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p>
Memory Slot {#SNMPVALUE} Part Number <p>-</p> SNMP agent MemPartlNo.[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p>
Memory Slot {#SNMPVALUE} Serial Number <p>-</p> SNMP agent MemSerialNo.[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p>
Memory Slot {#SNMPVALUE} Size <p>-</p> SNMP agent MemSize.[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p>
Memory Slot {#SNMPVALUE} Speed <p>-</p> SNMP agent MemSpeed.[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p>
Memory Slot {#SNMPVALUE} Status <p>-</p> SNMP agent MemStatus.[{#SNMPINDEX}]<p>Update: 30m</p><p>LLD</p>
NIC {#SNMPINDEX} : Connection Status <p>-</p> SNMP agent NetConnStatus.[{#SNMPINDEX}]<p>Update: 10m</p><p>LLD</p>
NIC {#SNMPINDEX} : MAC Address <p>-</p> SNMP agent NetMAC.[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p>
NIC {#SNMPINDEX} : Name <p>-</p> SNMP agent NetName.[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p>
NIC {#SNMPINDEX} : Slot <p>-</p> SNMP agent NetSlot.[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p>
NIC {#SNMPINDEX} : Status <p>-</p> SNMP agent NetStatus.[{#SNMPINDEX}]<p>Update: 5m</p><p>LLD</p>
Processor {#SNMPINDEX} Status <p>-</p> SNMP agent ProcStatus.[{#SNMPINDEX}]<p>Update: 5m</p><p>LLD</p>
Fan {#SNMPVALUE} Speed <p>-</p> SNMP agent FanSpeed.[{#SNMPINDEX}]<p>Update: 5m</p><p>LLD</p>
Fan {#SNMPVALUE} Status <p>-</p> SNMP agent FanStatus.[{#SNMPINDEX}]<p>Update: 5m</p><p>LLD</p>
Temperature Sensor {#SNMPVALUE} Critical Low-Limit <p>-</p> SNMP agent TempCritLowLimit.[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p>
Temperature Sensor {#SNMPVALUE} Critical Up-Limit <p>-</p> SNMP agent TempCritUpLimit.[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p>
Temperature Sensor {#SNMPVALUE} Status <p>-</p> SNMP agent TempStatus.[{#SNMPINDEX}]<p>Update: 5m</p><p>LLD</p>
Temperature Sensor {#SNMPVALUE} Value <p>-</p> SNMP agent TempValue.[{#SNMPINDEX}]<p>Update: 5m</p><p>LLD</p>
Temperature Sensor {#SNMPVALUE} Warning Low-Limit <p>-</p> SNMP agent TempWarnLowLimit.[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p>
Temperature Sensor {#SNMPVALUE} Warning Up-Limit <p>-</p> SNMP agent TempWarnUpLimit.[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p>
Volume {#SNMPINDEX} : Virtual Disk State <p>-</p> SNMP agent VolumeDiskState.[{#SNMPINDEX}]<p>Update: 1h</p><p>LLD</p>
Volume {#SNMPINDEX} : Name <p>-</p> SNMP agent VolumeName.[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p>
Volume {#SNMPINDEX} : Size <p>-</p> SNMP agent VolumeSize.[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p>
Volume {#SNMPINDEX} : State <p>-</p> SNMP agent VolumeState.[{#SNMPINDEX}]<p>Update: 1h</p><p>LLD</p>
Volume {#SNMPINDEX} : Status <p>-</p> SNMP agent VolumeStatus.[{#SNMPINDEX}]<p>Update: 1h</p><p>LLD</p>
Power Supply {#SNMPINDEX} Input Voltage <p>-</p> SNMP agent PowerSupplyInputVoltage.[{#SNMPINDEX}]<p>Update: 5m</p><p>LLD</p>
Power Supply {#SNMPINDEX} Maximum Power <p>-</p> SNMP agent PowerSupplyMaxPower.[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p>
Power Supply {#SNMPINDEX} Sensor State <p>-</p> SNMP agent PowerSupplySensorState.[{#SNMPINDEX}]<p>Update: 10m</p><p>LLD</p>
Power Supply {#SNMPINDEX} State Settings <p>-</p> SNMP agent PowerSupplyStateSettings.[{#SNMPINDEX}]<p>Update: 10m</p><p>LLD</p>
Power Supply {#SNMPINDEX} Status <p>-</p> SNMP agent PowerSupplyStatus.[{#SNMPINDEX}]<p>Update: 5m</p><p>LLD</p>

Triggers

Name Description Expression Priority
{HOST.NAME}: Problem with Disk {#SNMPINDEX} <p>-</p> <p>Expression: (last(/SNMP-iDRAC-9/DiskStatus.[{#SNMPINDEX}])<>3) and (last(/SNMP-iDRAC-9/SystemPowerState)=4)</p><p>Recovery expression: </p> disaster
{HOST.NAME}: Problem with FAN {#SNMPVALUE} <p>-</p> <p>Expression: (last(/SNMP-iDRAC-9/FanStatus.[{#SNMPINDEX}])<>3) and (last(/SNMP-iDRAC-9/SystemPowerState)=4)</p><p>Recovery expression: </p> average
{HOST.NAME}: Problem with memory in slot {#SNMPVALUE} <p>-</p> <p>Expression: (last(/SNMP-iDRAC-9/MemStatus.[{#SNMPINDEX}])<>3) and (last(/SNMP-iDRAC-9/SystemPowerState)=4)</p><p>Recovery expression: </p> high
{HOST.NAME}: Error on NIC {#SNMPINDEX} <p>-</p> <p>Expression: (last(/SNMP-iDRAC-9/NetStatus.[{#SNMPINDEX}])<>3) and (last(/SNMP-iDRAC-9/SystemPowerState)=4)</p><p>Recovery expression: </p> disaster
{HOST.NAME}: Error on PSU {#SNMPINDEX} State <p>-</p> <p>Expression: (last(/SNMP-iDRAC-9/PowerSupplySensorState.[{#SNMPINDEX}])<>1) and (last(/SNMP-iDRAC-9/SystemPowerState)=4)</p><p>Recovery expression: </p> high
{HOST.NAME}: Problem with PSU {#SNMPINDEX} <p>-</p> <p>Expression: (last(/SNMP-iDRAC-9/PowerSupplyStatus.[{#SNMPINDEX}])<>3) and (last(/SNMP-iDRAC-9/SystemPowerState)=4)</p><p>Recovery expression: </p> high
{HOST.NAME}: Error on Processor {#SNMPINDEX} <p>-</p> <p>Expression: (last(/SNMP-iDRAC-9/ProcStatus.[{#SNMPINDEX}])<>3) and (last(/SNMP-iDRAC-9/ProcStatus.[{#SNMPINDEX}])<>2) and (last(/SNMP-iDRAC-9/SystemPowerState)=4)</p><p>Recovery expression: </p> disaster
Problem with Temperature Sensor {#SNMPVALUE} <p>-</p> <p>Expression: last(/SNMP-iDRAC-9/TempStatus.[{#SNMPINDEX}])<>3</p><p>Recovery expression: </p> warning
Temperature on {#SNMPVALUE} critically high <p>Temperature of the item is above Critical Level.</p> <p>Expression: last(/SNMP-iDRAC-9/TempValue.[{#SNMPINDEX}]) >= last(/SNMP-iDRAC-9/TempCritUpLimit.[{#SNMPINDEX}])</p><p>Recovery expression: </p> high
Temperature on {#SNMPVALUE} critically low <p>Temperature of the item is below Critical Level.</p> <p>Expression: last(/SNMP-iDRAC-9/TempValue.[{#SNMPINDEX}]) <= last(/SNMP-iDRAC-9/TempCritLowLimit.[{#SNMPINDEX}])</p><p>Recovery expression: </p> high
Temperature on {#SNMPVALUE} to high <p>Temperature of the item is above Warning Level.</p> <p>Expression: last(/SNMP-iDRAC-9/TempValue.[{#SNMPINDEX}]) > last(/SNMP-iDRAC-9/TempWarnUpLimit.[{#SNMPINDEX}]) and last(/SNMP-iDRAC-9/TempValue.[{#SNMPINDEX}]) < last(/SNMP-iDRAC-9/TempCritUpLimit.[{#SNMPINDEX}])</p><p>Recovery expression: </p> warning
Temperature on {#SNMPVALUE} to low <p>Temperature of the item is below Warning Level.</p> <p>Expression: last(/SNMP-iDRAC-9/TempValue.[{#SNMPINDEX}]) < last(/SNMP-iDRAC-9/TempWarnLowLimit.[{#SNMPINDEX}]) and last(/SNMP-iDRAC-9/TempValue.[{#SNMPINDEX}]) > last(/SNMP-iDRAC-9/TempCritLowLimit.[{#SNMPINDEX}])</p><p>Recovery expression: </p> warning
{HOST.NAME}: Error on Voltage Sensor {#SNMPVALUE} <p>-</p> <p>Expression: (last(/SNMP-iDRAC-9/VoltageStatus.[{#SNMPINDEX}])<>3) and (last(/SNMP-iDRAC-9/SystemPowerState)=4)</p><p>Recovery expression: </p> average
{HOST.NAME}: Volume {#SNMPINDEX} Error <p>-</p> <p>Expression: (last(/SNMP-iDRAC-9/VolumeDiskState.[{#SNMPINDEX}])<>2) and (last(/SNMP-iDRAC-9/SystemPowerState)=4)</p><p>Recovery expression: </p> high
{HOST.NAME}: Volume {#SNMPINDEX} Status Error <p>-</p> <p>Expression: (last(/SNMP-iDRAC-9/VolumeStatus.[{#SNMPINDEX}])<>3) and (last(/SNMP-iDRAC-9/SystemPowerState)=4)</p><p>Recovery expression: </p> high
{HOST.NAME}: Error on Voltage Sensor {#SNMPVALUE} (LLD) <p>-</p> <p>Expression: (last(/SNMP-iDRAC-9/VoltageStatus.[{#SNMPINDEX}])<>3) and (last(/SNMP-iDRAC-9/SystemPowerState)=4)</p><p>Recovery expression: </p> average
{HOST.NAME}: Problem with Disk {#SNMPINDEX} (LLD) <p>-</p> <p>Expression: (last(/SNMP-iDRAC-9/DiskStatus.[{#SNMPINDEX}])<>3) and (last(/SNMP-iDRAC-9/SystemPowerState)=4)</p><p>Recovery expression: </p> disaster
{HOST.NAME}: Problem with memory in slot {#SNMPVALUE} (LLD) <p>-</p> <p>Expression: (last(/SNMP-iDRAC-9/MemStatus.[{#SNMPINDEX}])<>3) and (last(/SNMP-iDRAC-9/SystemPowerState)=4)</p><p>Recovery expression: </p> high
{HOST.NAME}: Error on NIC {#SNMPINDEX} (LLD) <p>-</p> <p>Expression: (last(/SNMP-iDRAC-9/NetStatus.[{#SNMPINDEX}])<>3) and (last(/SNMP-iDRAC-9/SystemPowerState)=4)</p><p>Recovery expression: </p> disaster
{HOST.NAME}: Error on Processor {#SNMPINDEX} (LLD) <p>-</p> <p>Expression: (last(/SNMP-iDRAC-9/ProcStatus.[{#SNMPINDEX}])<>3) and (last(/SNMP-iDRAC-9/ProcStatus.[{#SNMPINDEX}])<>2) and (last(/SNMP-iDRAC-9/SystemPowerState)=4)</p><p>Recovery expression: </p> disaster
{HOST.NAME}: Problem with FAN {#SNMPVALUE} (LLD) <p>-</p> <p>Expression: (last(/SNMP-iDRAC-9/FanStatus.[{#SNMPINDEX}])<>3) and (last(/SNMP-iDRAC-9/SystemPowerState)=4)</p><p>Recovery expression: </p> average
Problem with Temperature Sensor {#SNMPVALUE} (LLD) <p>-</p> <p>Expression: last(/SNMP-iDRAC-9/TempStatus.[{#SNMPINDEX}])<>3</p><p>Recovery expression: </p> warning
Temperature on {#SNMPVALUE} critically high (LLD) <p>Temperature of the item is above Critical Level.</p> <p>Expression: last(/SNMP-iDRAC-9/TempValue.[{#SNMPINDEX}]) >= last(/SNMP-iDRAC-9/TempCritUpLimit.[{#SNMPINDEX}])</p><p>Recovery expression: </p> high
Temperature on {#SNMPVALUE} critically low (LLD) <p>Temperature of the item is below Critical Level.</p> <p>Expression: last(/SNMP-iDRAC-9/TempValue.[{#SNMPINDEX}]) <= last(/SNMP-iDRAC-9/TempCritLowLimit.[{#SNMPINDEX}])</p><p>Recovery expression: </p> high
Temperature on {#SNMPVALUE} to high (LLD) <p>Temperature of the item is above Warning Level.</p> <p>Expression: last(/SNMP-iDRAC-9/TempValue.[{#SNMPINDEX}]) > last(/SNMP-iDRAC-9/TempWarnUpLimit.[{#SNMPINDEX}]) and last(/SNMP-iDRAC-9/TempValue.[{#SNMPINDEX}]) < last(/SNMP-iDRAC-9/TempCritUpLimit.[{#SNMPINDEX}])</p><p>Recovery expression: </p> warning
Temperature on {#SNMPVALUE} to low (LLD) <p>Temperature of the item is below Warning Level.</p> <p>Expression: last(/SNMP-iDRAC-9/TempValue.[{#SNMPINDEX}]) < last(/SNMP-iDRAC-9/TempWarnLowLimit.[{#SNMPINDEX}]) and last(/SNMP-iDRAC-9/TempValue.[{#SNMPINDEX}]) > last(/SNMP-iDRAC-9/TempCritLowLimit.[{#SNMPINDEX}])</p><p>Recovery expression: </p> warning
{HOST.NAME}: Volume {#SNMPINDEX} Error (LLD) <p>-</p> <p>Expression: (last(/SNMP-iDRAC-9/VolumeDiskState.[{#SNMPINDEX}])<>2) and (last(/SNMP-iDRAC-9/SystemPowerState)=4)</p><p>Recovery expression: </p> high
{HOST.NAME}: Volume {#SNMPINDEX} Status Error (LLD) <p>-</p> <p>Expression: (last(/SNMP-iDRAC-9/VolumeStatus.[{#SNMPINDEX}])<>3) and (last(/SNMP-iDRAC-9/SystemPowerState)=4)</p><p>Recovery expression: </p> high
{HOST.NAME}: Error on PSU {#SNMPINDEX} State (LLD) <p>-</p> <p>Expression: (last(/SNMP-iDRAC-9/PowerSupplySensorState.[{#SNMPINDEX}])<>1) and (last(/SNMP-iDRAC-9/SystemPowerState)=4)</p><p>Recovery expression: </p> high
{HOST.NAME}: Problem with PSU {#SNMPINDEX} (LLD) <p>-</p> <p>Expression: (last(/SNMP-iDRAC-9/PowerSupplyStatus.[{#SNMPINDEX}])<>3) and (last(/SNMP-iDRAC-9/SystemPowerState)=4)</p><p>Recovery expression: </p> high