Lucas Afonso Kremer https://www.linkedin.com/in/lucasafonsokremer
{$SNMP_COMMUNITY} with the community to be used
snmpstatus -v 2c -c public 192.168.0.1 Based on @endersonmaia iDRAC 7 template
Lucas Afonso Kremer
There are no macros links in this template.
There are no template links in this template.
Name | Description | Type | Key and additional info |
---|---|---|---|
Voltage Table Enumeration | <p>-</p> | SNMP agent |
VoltageTable<p>Update: 1d</p> |
Processor Enumeration | <p>-</p> | SNMP agent |
ProcEnum<p>Update: 1d</p> |
Disk Enumeration | <p>-</p> | SNMP agent |
DiskEnumeration<p>Update: 1d</p> |
Disk Volume Enumeration | <p>-</p> | SNMP agent |
VolumeEnum<p>Update: 1d</p> |
Temperature Enumeration | <p>-</p> | SNMP agent |
TempEnum<p>Update: 1d</p> |
Power Supply Enumeration | <p>-</p> | SNMP agent |
PowerSupplies<p>Update: 1d</p> |
Fan Enumeration | <p>-</p> | SNMP agent |
FanEnumeration<p>Update: 1d</p> |
Network Enumeration | <p>-</p> | SNMP agent |
NetworkEnum<p>Update: 1d</p> |
Memory Enumeration | <p>-</p> | SNMP agent |
MemoryEnum<p>Update: 1d;50s/1-7,00:00-24:00</p> |
Name | Description | Type | Key and additional info |
---|---|---|---|
Overall System Status | <p>-</p> | SNMP agent |
GlobalSystemStatus<p>Update: 5m</p> |
Overall System LCD Status | <p>-</p> | SNMP agent |
GlobalSystemLCDStatus<p>Update: 1h</p> |
Power Usage Minimum Idle Power | <p>-</p> | SNMP agent |
PowerUsageMinIdle<p>Update: 1h</p> |
BIOS Version | <p>-</p> | SNMP agent |
BiosVersion<p>Update: 1d</p> |
DRAC version | <p>-</p> | SNMP agent |
idrac_version<p>Update: 1d</p> |
System Express Service Code | <p>-</p> | SNMP agent |
idrac_esc<p>Update: 1d</p> |
RAID Controller : Firmware Version | <p>-</p> | SNMP agent |
RAIDControllerFirmware<p>Update: 1d</p> |
DRAC Firmware version | <p>-</p> | SNMP agent |
idrac_firmwareversion<p>Update: 1d</p> |
RAID Controller : Name | <p>-</p> | SNMP agent |
RAIDControllerName<p>Update: 1d</p> |
CMOS Battery Status | <p>-</p> | SNMP agent |
CMOSBatteryStatus<p>Update: 1h</p> |
System Asset Tag | <p>-</p> | SNMP agent |
idrac_assettag<p>Update: 1d</p> |
Voltage Status Combined | <p>-</p> | SNMP agent |
VoltageStatusCombined<p>Update: 10m</p> |
System Model | <p>-</p> | SNMP agent |
idrac_SystemModel<p>Update: 1d</p> |
System Power State | <p>4 server is on 3 server is on stand-by</p> | SNMP agent |
SystemPowerState<p>Update: 5m</p> |
Overall System Power State | <p>-</p> | SNMP agent |
GlobalSystemPowerState<p>Update: 1h</p> |
DRAC Access URL | <p>-</p> | SNMP agent |
idrac_acessurl<p>Update: 1d</p> |
System BIOS Status | <p>-</p> | SNMP agent |
SystemBiosStatus<p>Update: 1h</p> |
RAID Controller : Status | <p>-</p> | SNMP agent |
RAIDControllerStatus<p>Update: 10m</p> |
BIOS Date | <p>-</p> | SNMP agent |
BiosDate<p>Update: 1d</p> |
Power Usage Sensor Status | <p>-</p> | SNMP agent |
PowerUsageSensorStatus<p>Update: 1h</p> |
Overall System Storage Status | <p>-</p> | SNMP agent |
GlobalSystemStorageStatus<p>Update: 1h</p> |
Voltage : {#SNMPVALUE} Status | <p>-</p> | SNMP agent |
VoltageStatus.[{#SNMPINDEX}]<p>Update: 10m</p><p>LLD</p> |
Processor {#SNMPINDEX} Status | <p>-</p> | SNMP agent |
ProcStatus.[{#SNMPINDEX}]<p>Update: 5m</p><p>LLD</p> |
Disk {#SNMPINDEX} : Manufacture Day | <p>-</p> | SNMP agent |
DiskManufactureDay.[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p> |
Disk {#SNMPINDEX} : Manufacturer | <p>-</p> | SNMP agent |
DiskManufacturer.[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p> |
Disk {#SNMPINDEX} : Manufacture Week | <p>-</p> | SNMP agent |
DiskManufactureWeek.[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p> |
Disk {#SNMPINDEX} : Manufacture Year | <p>-</p> | SNMP agent |
DiskManufactureYear.[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p> |
Disk {#SNMPINDEX} : Model Number | <p>-</p> | SNMP agent |
DiskModel.[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p> |
Disk {#SNMPINDEX} : Name | <p>-</p> | SNMP agent |
DiskName.[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p> |
Disk {#SNMPINDEX} : Serial Number | <p>-</p> | SNMP agent |
DiskSerialNo.[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p> |
Disk {#SNMPINDEX} : Disk Size | <p>-</p> | SNMP agent |
DiskSize.[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p> |
Disk {#SNMPINDEX} : Disk State | <p>-</p> | SNMP agent |
DiskState.[{#SNMPINDEX}]<p>Update: 1h</p><p>LLD</p> |
Disk {#SNMPINDEX} : Disk Status | <p>-</p> | SNMP agent |
DiskStatus.[{#SNMPINDEX}]<p>Update: 1h</p><p>LLD</p> |
Volume {#SNMPINDEX} : Virtual Disk State | <p>-</p> | SNMP agent |
VolumeDiskState.[{#SNMPINDEX}]<p>Update: 1h</p><p>LLD</p> |
Volume {#SNMPINDEX} : Name | <p>-</p> | SNMP agent |
VolumeName.[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p> |
Volume {#SNMPINDEX} : Size | <p>-</p> | SNMP agent |
VolumeSize.[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p> |
Volume {#SNMPINDEX} : State | <p>-</p> | SNMP agent |
VolumeState.[{#SNMPINDEX}]<p>Update: 1h</p><p>LLD</p> |
Volume {#SNMPINDEX} : Status | <p>-</p> | SNMP agent |
VolumeStatus.[{#SNMPINDEX}]<p>Update: 1h</p><p>LLD</p> |
Temperature Sensor {#SNMPVALUE} Critical Low-Limit | <p>-</p> | SNMP agent |
TempCritLowLimit.[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p> |
Temperature Sensor {#SNMPVALUE} Critical Up-Limit | <p>-</p> | SNMP agent |
TempCritUpLimit.[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p> |
Temperature Sensor {#SNMPVALUE} Status | <p>-</p> | SNMP agent |
TempStatus.[{#SNMPINDEX}]<p>Update: 5m</p><p>LLD</p> |
Temperature Sensor {#SNMPVALUE} Value | <p>-</p> | SNMP agent |
TempValue.[{#SNMPINDEX}]<p>Update: 5m</p><p>LLD</p> |
Temperature Sensor {#SNMPVALUE} Warning Low-Limit | <p>-</p> | SNMP agent |
TempWarnLowLimit.[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p> |
Temperature Sensor {#SNMPVALUE} Warning Up-Limit | <p>-</p> | SNMP agent |
TempWarnUpLimit.[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p> |
Power Supply {#SNMPINDEX} Input Voltage | <p>-</p> | SNMP agent |
PowerSupplyInputVoltage.[{#SNMPINDEX}]<p>Update: 5m</p><p>LLD</p> |
Power Supply {#SNMPINDEX} Maximum Power | <p>-</p> | SNMP agent |
PowerSupplyMaxPower.[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p> |
Power Supply {#SNMPINDEX} Sensor State | <p>-</p> | SNMP agent |
PowerSupplySensorState.[{#SNMPINDEX}]<p>Update: 10m</p><p>LLD</p> |
Power Supply {#SNMPINDEX} State Settings | <p>-</p> | SNMP agent |
PowerSupplyStateSettings.[{#SNMPINDEX}]<p>Update: 10m</p><p>LLD</p> |
Power Supply {#SNMPINDEX} Status | <p>-</p> | SNMP agent |
PowerSupplyStatus.[{#SNMPINDEX}]<p>Update: 5m</p><p>LLD</p> |
Fan {#SNMPVALUE} Speed | <p>-</p> | SNMP agent |
FanSpeed.[{#SNMPINDEX}]<p>Update: 5m</p><p>LLD</p> |
Fan {#SNMPVALUE} Status | <p>-</p> | SNMP agent |
FanStatus.[{#SNMPINDEX}]<p>Update: 5m</p><p>LLD</p> |
NIC {#SNMPINDEX} : Connection Status | <p>-</p> | SNMP agent |
NetConnStatus.[{#SNMPINDEX}]<p>Update: 10m</p><p>LLD</p> |
NIC {#SNMPINDEX} : MAC Address | <p>-</p> | SNMP agent |
NetMAC.[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p> |
NIC {#SNMPINDEX} : Name | <p>-</p> | SNMP agent |
NetName.[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p> |
NIC {#SNMPINDEX} : Slot | <p>-</p> | SNMP agent |
NetSlot.[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p> |
NIC {#SNMPINDEX} : Status | <p>-</p> | SNMP agent |
NetStatus.[{#SNMPINDEX}]<p>Update: 5m</p><p>LLD</p> |
Memory Slot {#SNMPVALUE} Manufacturer | <p>-</p> | SNMP agent |
MemManufacturer[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p> |
Memory Slot {#SNMPVALUE} Part Number | <p>-</p> | SNMP agent |
MemPartlNo.[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p> |
Memory Slot {#SNMPVALUE} Serial Number | <p>-</p> | SNMP agent |
MemSerialNo.[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p> |
Memory Slot {#SNMPVALUE} Size | <p>-</p> | SNMP agent |
MemSize.[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p> |
Memory Slot {#SNMPVALUE} Speed | <p>-</p> | SNMP agent |
MemSpeed.[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p> |
Memory Slot {#SNMPVALUE} Status | <p>-</p> | SNMP agent |
MemStatus.[{#SNMPINDEX}]<p>Update: 30m</p><p>LLD</p> |
Name | Description | Expression | Priority |
---|---|---|---|
{HOST.NAME}: Problem with Disk {#SNMPINDEX} | <p>-</p> | <p>Expression: ({SNMP-iDRAC-9:DiskStatus.[{#SNMPINDEX}].last(0)}<>3) and ({SNMP-iDRAC-9:SystemPowerState.last(0)}=4)</p><p>Recovery expression: </p> | disaster |
{HOST.NAME}: Problem with FAN {#SNMPVALUE} | <p>-</p> | <p>Expression: ({SNMP-iDRAC-9:FanStatus.[{#SNMPINDEX}].last(0)}<>3) and ({SNMP-iDRAC-9:SystemPowerState.last(0)}=4)</p><p>Recovery expression: </p> | average |
{HOST.NAME}: Problem with memory in slot {#SNMPVALUE} | <p>-</p> | <p>Expression: ({SNMP-iDRAC-9:MemStatus.[{#SNMPINDEX}].last(0)}<>3) and ({SNMP-iDRAC-9:SystemPowerState.last(0)}=4)</p><p>Recovery expression: </p> | high |
{HOST.NAME}: Error on NIC {#SNMPINDEX} | <p>-</p> | <p>Expression: ({SNMP-iDRAC-9:NetStatus.[{#SNMPINDEX}].last(0)}<>3) and ({SNMP-iDRAC-9:SystemPowerState.last(0)}=4)</p><p>Recovery expression: </p> | disaster |
{HOST.NAME}: Error on PSU {#SNMPINDEX} State | <p>-</p> | <p>Expression: ({SNMP-iDRAC-9:PowerSupplySensorState.[{#SNMPINDEX}].last(0)}<>1) and ({SNMP-iDRAC-9:SystemPowerState.last(0)}=4)</p><p>Recovery expression: </p> | high |
{HOST.NAME}: Problem with PSU {#SNMPINDEX} | <p>-</p> | <p>Expression: ({SNMP-iDRAC-9:PowerSupplyStatus.[{#SNMPINDEX}].last(0)}<>3) and ({SNMP-iDRAC-9:SystemPowerState.last(0)}=4)</p><p>Recovery expression: </p> | high |
{HOST.NAME}: Error on Processor {#SNMPINDEX} | <p>-</p> | <p>Expression: ({SNMP-iDRAC-9:ProcStatus.[{#SNMPINDEX}].last(0)}<>3) and ({SNMP-iDRAC-9:ProcStatus.[{#SNMPINDEX}].last(0)}<>2) and ({SNMP-iDRAC-9:SystemPowerState.last(0)}=4)</p><p>Recovery expression: </p> | disaster |
Problem with Temperature Sensor {#SNMPVALUE} | <p>-</p> | <p>Expression: {SNMP-iDRAC-9:TempStatus.[{#SNMPINDEX}].last(0)}<>3</p><p>Recovery expression: </p> | warning |
Temperature on {#SNMPVALUE} critically high | <p>Temperature of the item is above Critical Level.</p> | <p>Expression: {SNMP-iDRAC-9:TempValue.[{#SNMPINDEX}].last()} >= {SNMP-iDRAC-9:TempCritUpLimit.[{#SNMPINDEX}].last()}</p><p>Recovery expression: </p> | high |
Temperature on {#SNMPVALUE} critically low | <p>Temperature of the item is below Critical Level.</p> | <p>Expression: {SNMP-iDRAC-9:TempValue.[{#SNMPINDEX}].last()} <= {SNMP-iDRAC-9:TempCritLowLimit.[{#SNMPINDEX}].last()}</p><p>Recovery expression: </p> | high |
Temperature on {#SNMPVALUE} to high | <p>Temperature of the item is above Warning Level.</p> | <p>Expression: {SNMP-iDRAC-9:TempValue.[{#SNMPINDEX}].last()} > {SNMP-iDRAC-9:TempWarnUpLimit.[{#SNMPINDEX}].last()} and {SNMP-iDRAC-9:TempValue.[{#SNMPINDEX}].last()} < {SNMP-iDRAC-9:TempCritUpLimit.[{#SNMPINDEX}].last()}</p><p>Recovery expression: </p> | warning |
Temperature on {#SNMPVALUE} to low | <p>Temperature of the item is below Warning Level.</p> | <p>Expression: {SNMP-iDRAC-9:TempValue.[{#SNMPINDEX}].last()} < {SNMP-iDRAC-9:TempWarnLowLimit.[{#SNMPINDEX}].last()} and {SNMP-iDRAC-9:TempValue.[{#SNMPINDEX}].last()} > {SNMP-iDRAC-9:TempCritLowLimit.[{#SNMPINDEX}].last()}</p><p>Recovery expression: </p> | warning |
{HOST.NAME}: Error on Voltage Sensor {#SNMPVALUE} | <p>-</p> | <p>Expression: ({SNMP-iDRAC-9:VoltageStatus.[{#SNMPINDEX}].last(0)}<>3) and ({SNMP-iDRAC-9:SystemPowerState.last(0)}=4)</p><p>Recovery expression: </p> | average |
{HOST.NAME}: Volume {#SNMPINDEX} Error | <p>-</p> | <p>Expression: ({SNMP-iDRAC-9:VolumeDiskState.[{#SNMPINDEX}].last(0)}<>2) and ({SNMP-iDRAC-9:SystemPowerState.last(0)}=4)</p><p>Recovery expression: </p> | high |
{HOST.NAME}: Volume {#SNMPINDEX} Status Error | <p>-</p> | <p>Expression: ({SNMP-iDRAC-9:VolumeStatus.[{#SNMPINDEX}].last(0)}<>3) and ({SNMP-iDRAC-9:SystemPowerState.last(0)}=4)</p><p>Recovery expression: </p> | high |
{HOST.NAME}: Error on Voltage Sensor {#SNMPVALUE} (LLD) | <p>-</p> | <p>Expression: ({SNMP-iDRAC-9:VoltageStatus.[{#SNMPINDEX}].last(0)}<>3) and ({SNMP-iDRAC-9:SystemPowerState.last(0)}=4)</p><p>Recovery expression: </p> | average |
{HOST.NAME}: Error on Processor {#SNMPINDEX} (LLD) | <p>-</p> | <p>Expression: ({SNMP-iDRAC-9:ProcStatus.[{#SNMPINDEX}].last(0)}<>3) and ({SNMP-iDRAC-9:ProcStatus.[{#SNMPINDEX}].last(0)}<>2) and ({SNMP-iDRAC-9:SystemPowerState.last(0)}=4)</p><p>Recovery expression: </p> | disaster |
{HOST.NAME}: Problem with Disk {#SNMPINDEX} (LLD) | <p>-</p> | <p>Expression: ({SNMP-iDRAC-9:DiskStatus.[{#SNMPINDEX}].last(0)}<>3) and ({SNMP-iDRAC-9:SystemPowerState.last(0)}=4)</p><p>Recovery expression: </p> | disaster |
{HOST.NAME}: Volume {#SNMPINDEX} Error (LLD) | <p>-</p> | <p>Expression: ({SNMP-iDRAC-9:VolumeDiskState.[{#SNMPINDEX}].last(0)}<>2) and ({SNMP-iDRAC-9:SystemPowerState.last(0)}=4)</p><p>Recovery expression: </p> | high |
{HOST.NAME}: Volume {#SNMPINDEX} Status Error (LLD) | <p>-</p> | <p>Expression: ({SNMP-iDRAC-9:VolumeStatus.[{#SNMPINDEX}].last(0)}<>3) and ({SNMP-iDRAC-9:SystemPowerState.last(0)}=4)</p><p>Recovery expression: </p> | high |
Problem with Temperature Sensor {#SNMPVALUE} (LLD) | <p>-</p> | <p>Expression: {SNMP-iDRAC-9:TempStatus.[{#SNMPINDEX}].last(0)}<>3</p><p>Recovery expression: </p> | warning |
Temperature on {#SNMPVALUE} critically high (LLD) | <p>Temperature of the item is above Critical Level.</p> | <p>Expression: {SNMP-iDRAC-9:TempValue.[{#SNMPINDEX}].last()} >= {SNMP-iDRAC-9:TempCritUpLimit.[{#SNMPINDEX}].last()}</p><p>Recovery expression: </p> | high |
Temperature on {#SNMPVALUE} critically low (LLD) | <p>Temperature of the item is below Critical Level.</p> | <p>Expression: {SNMP-iDRAC-9:TempValue.[{#SNMPINDEX}].last()} <= {SNMP-iDRAC-9:TempCritLowLimit.[{#SNMPINDEX}].last()}</p><p>Recovery expression: </p> | high |
Temperature on {#SNMPVALUE} to high (LLD) | <p>Temperature of the item is above Warning Level.</p> | <p>Expression: {SNMP-iDRAC-9:TempValue.[{#SNMPINDEX}].last()} > {SNMP-iDRAC-9:TempWarnUpLimit.[{#SNMPINDEX}].last()} and {SNMP-iDRAC-9:TempValue.[{#SNMPINDEX}].last()} < {SNMP-iDRAC-9:TempCritUpLimit.[{#SNMPINDEX}].last()}</p><p>Recovery expression: </p> | warning |
Temperature on {#SNMPVALUE} to low (LLD) | <p>Temperature of the item is below Warning Level.</p> | <p>Expression: {SNMP-iDRAC-9:TempValue.[{#SNMPINDEX}].last()} < {SNMP-iDRAC-9:TempWarnLowLimit.[{#SNMPINDEX}].last()} and {SNMP-iDRAC-9:TempValue.[{#SNMPINDEX}].last()} > {SNMP-iDRAC-9:TempCritLowLimit.[{#SNMPINDEX}].last()}</p><p>Recovery expression: </p> | warning |
{HOST.NAME}: Error on PSU {#SNMPINDEX} State (LLD) | <p>-</p> | <p>Expression: ({SNMP-iDRAC-9:PowerSupplySensorState.[{#SNMPINDEX}].last(0)}<>1) and ({SNMP-iDRAC-9:SystemPowerState.last(0)}=4)</p><p>Recovery expression: </p> | high |
{HOST.NAME}: Problem with PSU {#SNMPINDEX} (LLD) | <p>-</p> | <p>Expression: ({SNMP-iDRAC-9:PowerSupplyStatus.[{#SNMPINDEX}].last(0)}<>3) and ({SNMP-iDRAC-9:SystemPowerState.last(0)}=4)</p><p>Recovery expression: </p> | high |
{HOST.NAME}: Problem with FAN {#SNMPVALUE} (LLD) | <p>-</p> | <p>Expression: ({SNMP-iDRAC-9:FanStatus.[{#SNMPINDEX}].last(0)}<>3) and ({SNMP-iDRAC-9:SystemPowerState.last(0)}=4)</p><p>Recovery expression: </p> | average |
{HOST.NAME}: Error on NIC {#SNMPINDEX} (LLD) | <p>-</p> | <p>Expression: ({SNMP-iDRAC-9:NetStatus.[{#SNMPINDEX}].last(0)}<>3) and ({SNMP-iDRAC-9:SystemPowerState.last(0)}=4)</p><p>Recovery expression: </p> | disaster |
{HOST.NAME}: Problem with memory in slot {#SNMPVALUE} (LLD) | <p>-</p> | <p>Expression: ({SNMP-iDRAC-9:MemStatus.[{#SNMPINDEX}].last(0)}<>3) and ({SNMP-iDRAC-9:SystemPowerState.last(0)}=4)</p><p>Recovery expression: </p> | high |
Lucas Afonso Kremer https://www.linkedin.com/in/lucasafonsokremer
{$SNMP_COMMUNITY} with the community to be used
snmpstatus -v 2c -c public 192.168.0.1 Based on @endersonmaia iDRAC 7 template
Lucas Afonso Kremer
There are no macros links in this template.
There are no template links in this template.
Name | Description | Type | Key and additional info |
---|---|---|---|
Voltage Table Enumeration | <p>-</p> | SNMP agent |
VoltageTable<p>Update: 1d</p> |
Disk Enumeration | <p>-</p> | SNMP agent |
DiskEnumeration<p>Update: 1d</p> |
Memory Enumeration | <p>-</p> | SNMP agent |
MemoryEnum<p>Update: 1d;50s/1-7,00:00-24:00</p> |
Network Enumeration | <p>-</p> | SNMP agent |
NetworkEnum<p>Update: 1d</p> |
Processor Enumeration | <p>-</p> | SNMP agent |
ProcEnum<p>Update: 1d</p> |
Fan Enumeration | <p>-</p> | SNMP agent |
FanEnumeration<p>Update: 1d</p> |
Temperature Enumeration | <p>-</p> | SNMP agent |
TempEnum<p>Update: 1d</p> |
Disk Volume Enumeration | <p>-</p> | SNMP agent |
VolumeEnum<p>Update: 1d</p> |
Power Supply Enumeration | <p>-</p> | SNMP agent |
PowerSupplies<p>Update: 1d</p> |
Name | Description | Type | Key and additional info |
---|---|---|---|
DRAC Access URL | <p>-</p> | SNMP agent |
idrac_acessurl<p>Update: 1d</p> |
RAID Controller : Name | <p>-</p> | SNMP agent |
RAIDControllerName<p>Update: 1d</p> |
System Express Service Code | <p>-</p> | SNMP agent |
idrac_esc<p>Update: 1d</p> |
Voltage Status Combined | <p>-</p> | SNMP agent |
VoltageStatusCombined<p>Update: 10m</p> |
Overall System Power State | <p>-</p> | SNMP agent |
GlobalSystemPowerState<p>Update: 1h</p> |
RAID Controller : Firmware Version | <p>-</p> | SNMP agent |
RAIDControllerFirmware<p>Update: 1d</p> |
CMOS Battery Status | <p>-</p> | SNMP agent |
CMOSBatteryStatus<p>Update: 1h</p> |
RAID Controller : Status | <p>-</p> | SNMP agent |
RAIDControllerStatus<p>Update: 10m</p> |
BIOS Date | <p>-</p> | SNMP agent |
BiosDate<p>Update: 1d</p> |
DRAC version | <p>-</p> | SNMP agent |
idrac_version<p>Update: 1d</p> |
System BIOS Status | <p>-</p> | SNMP agent |
SystemBiosStatus<p>Update: 1h</p> |
System Power State | <p>4 server is on 3 server is on stand-by</p> | SNMP agent |
SystemPowerState<p>Update: 5m</p> |
Overall System LCD Status | <p>-</p> | SNMP agent |
GlobalSystemLCDStatus<p>Update: 1h</p> |
Power Usage Minimum Idle Power | <p>-</p> | SNMP agent |
PowerUsageMinIdle<p>Update: 1h</p> |
Overall System Storage Status | <p>-</p> | SNMP agent |
GlobalSystemStorageStatus<p>Update: 1h</p> |
System Model | <p>-</p> | SNMP agent |
idrac_SystemModel<p>Update: 1d</p> |
Overall System Status | <p>-</p> | SNMP agent |
GlobalSystemStatus<p>Update: 5m</p> |
System Asset Tag | <p>-</p> | SNMP agent |
idrac_assettag<p>Update: 1d</p> |
Power Usage Sensor Status | <p>-</p> | SNMP agent |
PowerUsageSensorStatus<p>Update: 1h</p> |
BIOS Version | <p>-</p> | SNMP agent |
BiosVersion<p>Update: 1d</p> |
DRAC Firmware version | <p>-</p> | SNMP agent |
idrac_firmwareversion<p>Update: 1d</p> |
Voltage : {#SNMPVALUE} Status | <p>-</p> | SNMP agent |
VoltageStatus.[{#SNMPINDEX}]<p>Update: 10m</p><p>LLD</p> |
Disk {#SNMPINDEX} : Manufacture Day | <p>-</p> | SNMP agent |
DiskManufactureDay.[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p> |
Disk {#SNMPINDEX} : Manufacturer | <p>-</p> | SNMP agent |
DiskManufacturer.[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p> |
Disk {#SNMPINDEX} : Manufacture Week | <p>-</p> | SNMP agent |
DiskManufactureWeek.[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p> |
Disk {#SNMPINDEX} : Manufacture Year | <p>-</p> | SNMP agent |
DiskManufactureYear.[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p> |
Disk {#SNMPINDEX} : Model Number | <p>-</p> | SNMP agent |
DiskModel.[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p> |
Disk {#SNMPINDEX} : Name | <p>-</p> | SNMP agent |
DiskName.[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p> |
Disk {#SNMPINDEX} : Serial Number | <p>-</p> | SNMP agent |
DiskSerialNo.[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p> |
Disk {#SNMPINDEX} : Disk Size | <p>-</p> | SNMP agent |
DiskSize.[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p> |
Disk {#SNMPINDEX} : Disk State | <p>-</p> | SNMP agent |
DiskState.[{#SNMPINDEX}]<p>Update: 1h</p><p>LLD</p> |
Disk {#SNMPINDEX} : Disk Status | <p>-</p> | SNMP agent |
DiskStatus.[{#SNMPINDEX}]<p>Update: 1h</p><p>LLD</p> |
Memory Slot {#SNMPVALUE} Manufacturer | <p>-</p> | SNMP agent |
MemManufacturer[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p> |
Memory Slot {#SNMPVALUE} Part Number | <p>-</p> | SNMP agent |
MemPartlNo.[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p> |
Memory Slot {#SNMPVALUE} Serial Number | <p>-</p> | SNMP agent |
MemSerialNo.[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p> |
Memory Slot {#SNMPVALUE} Size | <p>-</p> | SNMP agent |
MemSize.[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p> |
Memory Slot {#SNMPVALUE} Speed | <p>-</p> | SNMP agent |
MemSpeed.[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p> |
Memory Slot {#SNMPVALUE} Status | <p>-</p> | SNMP agent |
MemStatus.[{#SNMPINDEX}]<p>Update: 30m</p><p>LLD</p> |
NIC {#SNMPINDEX} : Connection Status | <p>-</p> | SNMP agent |
NetConnStatus.[{#SNMPINDEX}]<p>Update: 10m</p><p>LLD</p> |
NIC {#SNMPINDEX} : MAC Address | <p>-</p> | SNMP agent |
NetMAC.[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p> |
NIC {#SNMPINDEX} : Name | <p>-</p> | SNMP agent |
NetName.[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p> |
NIC {#SNMPINDEX} : Slot | <p>-</p> | SNMP agent |
NetSlot.[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p> |
NIC {#SNMPINDEX} : Status | <p>-</p> | SNMP agent |
NetStatus.[{#SNMPINDEX}]<p>Update: 5m</p><p>LLD</p> |
Processor {#SNMPINDEX} Status | <p>-</p> | SNMP agent |
ProcStatus.[{#SNMPINDEX}]<p>Update: 5m</p><p>LLD</p> |
Fan {#SNMPVALUE} Speed | <p>-</p> | SNMP agent |
FanSpeed.[{#SNMPINDEX}]<p>Update: 5m</p><p>LLD</p> |
Fan {#SNMPVALUE} Status | <p>-</p> | SNMP agent |
FanStatus.[{#SNMPINDEX}]<p>Update: 5m</p><p>LLD</p> |
Temperature Sensor {#SNMPVALUE} Critical Low-Limit | <p>-</p> | SNMP agent |
TempCritLowLimit.[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p> |
Temperature Sensor {#SNMPVALUE} Critical Up-Limit | <p>-</p> | SNMP agent |
TempCritUpLimit.[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p> |
Temperature Sensor {#SNMPVALUE} Status | <p>-</p> | SNMP agent |
TempStatus.[{#SNMPINDEX}]<p>Update: 5m</p><p>LLD</p> |
Temperature Sensor {#SNMPVALUE} Value | <p>-</p> | SNMP agent |
TempValue.[{#SNMPINDEX}]<p>Update: 5m</p><p>LLD</p> |
Temperature Sensor {#SNMPVALUE} Warning Low-Limit | <p>-</p> | SNMP agent |
TempWarnLowLimit.[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p> |
Temperature Sensor {#SNMPVALUE} Warning Up-Limit | <p>-</p> | SNMP agent |
TempWarnUpLimit.[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p> |
Volume {#SNMPINDEX} : Virtual Disk State | <p>-</p> | SNMP agent |
VolumeDiskState.[{#SNMPINDEX}]<p>Update: 1h</p><p>LLD</p> |
Volume {#SNMPINDEX} : Name | <p>-</p> | SNMP agent |
VolumeName.[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p> |
Volume {#SNMPINDEX} : Size | <p>-</p> | SNMP agent |
VolumeSize.[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p> |
Volume {#SNMPINDEX} : State | <p>-</p> | SNMP agent |
VolumeState.[{#SNMPINDEX}]<p>Update: 1h</p><p>LLD</p> |
Volume {#SNMPINDEX} : Status | <p>-</p> | SNMP agent |
VolumeStatus.[{#SNMPINDEX}]<p>Update: 1h</p><p>LLD</p> |
Power Supply {#SNMPINDEX} Input Voltage | <p>-</p> | SNMP agent |
PowerSupplyInputVoltage.[{#SNMPINDEX}]<p>Update: 5m</p><p>LLD</p> |
Power Supply {#SNMPINDEX} Maximum Power | <p>-</p> | SNMP agent |
PowerSupplyMaxPower.[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p> |
Power Supply {#SNMPINDEX} Sensor State | <p>-</p> | SNMP agent |
PowerSupplySensorState.[{#SNMPINDEX}]<p>Update: 10m</p><p>LLD</p> |
Power Supply {#SNMPINDEX} State Settings | <p>-</p> | SNMP agent |
PowerSupplyStateSettings.[{#SNMPINDEX}]<p>Update: 10m</p><p>LLD</p> |
Power Supply {#SNMPINDEX} Status | <p>-</p> | SNMP agent |
PowerSupplyStatus.[{#SNMPINDEX}]<p>Update: 5m</p><p>LLD</p> |
Name | Description | Expression | Priority |
---|---|---|---|
{HOST.NAME}: Problem with Disk {#SNMPINDEX} | <p>-</p> | <p>Expression: (last(/SNMP-iDRAC-9/DiskStatus.[{#SNMPINDEX}])<>3) and (last(/SNMP-iDRAC-9/SystemPowerState)=4)</p><p>Recovery expression: </p> | disaster |
{HOST.NAME}: Problem with FAN {#SNMPVALUE} | <p>-</p> | <p>Expression: (last(/SNMP-iDRAC-9/FanStatus.[{#SNMPINDEX}])<>3) and (last(/SNMP-iDRAC-9/SystemPowerState)=4)</p><p>Recovery expression: </p> | average |
{HOST.NAME}: Problem with memory in slot {#SNMPVALUE} | <p>-</p> | <p>Expression: (last(/SNMP-iDRAC-9/MemStatus.[{#SNMPINDEX}])<>3) and (last(/SNMP-iDRAC-9/SystemPowerState)=4)</p><p>Recovery expression: </p> | high |
{HOST.NAME}: Error on NIC {#SNMPINDEX} | <p>-</p> | <p>Expression: (last(/SNMP-iDRAC-9/NetStatus.[{#SNMPINDEX}])<>3) and (last(/SNMP-iDRAC-9/SystemPowerState)=4)</p><p>Recovery expression: </p> | disaster |
{HOST.NAME}: Error on PSU {#SNMPINDEX} State | <p>-</p> | <p>Expression: (last(/SNMP-iDRAC-9/PowerSupplySensorState.[{#SNMPINDEX}])<>1) and (last(/SNMP-iDRAC-9/SystemPowerState)=4)</p><p>Recovery expression: </p> | high |
{HOST.NAME}: Problem with PSU {#SNMPINDEX} | <p>-</p> | <p>Expression: (last(/SNMP-iDRAC-9/PowerSupplyStatus.[{#SNMPINDEX}])<>3) and (last(/SNMP-iDRAC-9/SystemPowerState)=4)</p><p>Recovery expression: </p> | high |
{HOST.NAME}: Error on Processor {#SNMPINDEX} | <p>-</p> | <p>Expression: (last(/SNMP-iDRAC-9/ProcStatus.[{#SNMPINDEX}])<>3) and (last(/SNMP-iDRAC-9/ProcStatus.[{#SNMPINDEX}])<>2) and (last(/SNMP-iDRAC-9/SystemPowerState)=4)</p><p>Recovery expression: </p> | disaster |
Problem with Temperature Sensor {#SNMPVALUE} | <p>-</p> | <p>Expression: last(/SNMP-iDRAC-9/TempStatus.[{#SNMPINDEX}])<>3</p><p>Recovery expression: </p> | warning |
Temperature on {#SNMPVALUE} critically high | <p>Temperature of the item is above Critical Level.</p> | <p>Expression: last(/SNMP-iDRAC-9/TempValue.[{#SNMPINDEX}]) >= last(/SNMP-iDRAC-9/TempCritUpLimit.[{#SNMPINDEX}])</p><p>Recovery expression: </p> | high |
Temperature on {#SNMPVALUE} critically low | <p>Temperature of the item is below Critical Level.</p> | <p>Expression: last(/SNMP-iDRAC-9/TempValue.[{#SNMPINDEX}]) <= last(/SNMP-iDRAC-9/TempCritLowLimit.[{#SNMPINDEX}])</p><p>Recovery expression: </p> | high |
Temperature on {#SNMPVALUE} to high | <p>Temperature of the item is above Warning Level.</p> | <p>Expression: last(/SNMP-iDRAC-9/TempValue.[{#SNMPINDEX}]) > last(/SNMP-iDRAC-9/TempWarnUpLimit.[{#SNMPINDEX}]) and last(/SNMP-iDRAC-9/TempValue.[{#SNMPINDEX}]) < last(/SNMP-iDRAC-9/TempCritUpLimit.[{#SNMPINDEX}])</p><p>Recovery expression: </p> | warning |
Temperature on {#SNMPVALUE} to low | <p>Temperature of the item is below Warning Level.</p> | <p>Expression: last(/SNMP-iDRAC-9/TempValue.[{#SNMPINDEX}]) < last(/SNMP-iDRAC-9/TempWarnLowLimit.[{#SNMPINDEX}]) and last(/SNMP-iDRAC-9/TempValue.[{#SNMPINDEX}]) > last(/SNMP-iDRAC-9/TempCritLowLimit.[{#SNMPINDEX}])</p><p>Recovery expression: </p> | warning |
{HOST.NAME}: Error on Voltage Sensor {#SNMPVALUE} | <p>-</p> | <p>Expression: (last(/SNMP-iDRAC-9/VoltageStatus.[{#SNMPINDEX}])<>3) and (last(/SNMP-iDRAC-9/SystemPowerState)=4)</p><p>Recovery expression: </p> | average |
{HOST.NAME}: Volume {#SNMPINDEX} Error | <p>-</p> | <p>Expression: (last(/SNMP-iDRAC-9/VolumeDiskState.[{#SNMPINDEX}])<>2) and (last(/SNMP-iDRAC-9/SystemPowerState)=4)</p><p>Recovery expression: </p> | high |
{HOST.NAME}: Volume {#SNMPINDEX} Status Error | <p>-</p> | <p>Expression: (last(/SNMP-iDRAC-9/VolumeStatus.[{#SNMPINDEX}])<>3) and (last(/SNMP-iDRAC-9/SystemPowerState)=4)</p><p>Recovery expression: </p> | high |
{HOST.NAME}: Error on Voltage Sensor {#SNMPVALUE} (LLD) | <p>-</p> | <p>Expression: (last(/SNMP-iDRAC-9/VoltageStatus.[{#SNMPINDEX}])<>3) and (last(/SNMP-iDRAC-9/SystemPowerState)=4)</p><p>Recovery expression: </p> | average |
{HOST.NAME}: Problem with Disk {#SNMPINDEX} (LLD) | <p>-</p> | <p>Expression: (last(/SNMP-iDRAC-9/DiskStatus.[{#SNMPINDEX}])<>3) and (last(/SNMP-iDRAC-9/SystemPowerState)=4)</p><p>Recovery expression: </p> | disaster |
{HOST.NAME}: Problem with memory in slot {#SNMPVALUE} (LLD) | <p>-</p> | <p>Expression: (last(/SNMP-iDRAC-9/MemStatus.[{#SNMPINDEX}])<>3) and (last(/SNMP-iDRAC-9/SystemPowerState)=4)</p><p>Recovery expression: </p> | high |
{HOST.NAME}: Error on NIC {#SNMPINDEX} (LLD) | <p>-</p> | <p>Expression: (last(/SNMP-iDRAC-9/NetStatus.[{#SNMPINDEX}])<>3) and (last(/SNMP-iDRAC-9/SystemPowerState)=4)</p><p>Recovery expression: </p> | disaster |
{HOST.NAME}: Error on Processor {#SNMPINDEX} (LLD) | <p>-</p> | <p>Expression: (last(/SNMP-iDRAC-9/ProcStatus.[{#SNMPINDEX}])<>3) and (last(/SNMP-iDRAC-9/ProcStatus.[{#SNMPINDEX}])<>2) and (last(/SNMP-iDRAC-9/SystemPowerState)=4)</p><p>Recovery expression: </p> | disaster |
{HOST.NAME}: Problem with FAN {#SNMPVALUE} (LLD) | <p>-</p> | <p>Expression: (last(/SNMP-iDRAC-9/FanStatus.[{#SNMPINDEX}])<>3) and (last(/SNMP-iDRAC-9/SystemPowerState)=4)</p><p>Recovery expression: </p> | average |
Problem with Temperature Sensor {#SNMPVALUE} (LLD) | <p>-</p> | <p>Expression: last(/SNMP-iDRAC-9/TempStatus.[{#SNMPINDEX}])<>3</p><p>Recovery expression: </p> | warning |
Temperature on {#SNMPVALUE} critically high (LLD) | <p>Temperature of the item is above Critical Level.</p> | <p>Expression: last(/SNMP-iDRAC-9/TempValue.[{#SNMPINDEX}]) >= last(/SNMP-iDRAC-9/TempCritUpLimit.[{#SNMPINDEX}])</p><p>Recovery expression: </p> | high |
Temperature on {#SNMPVALUE} critically low (LLD) | <p>Temperature of the item is below Critical Level.</p> | <p>Expression: last(/SNMP-iDRAC-9/TempValue.[{#SNMPINDEX}]) <= last(/SNMP-iDRAC-9/TempCritLowLimit.[{#SNMPINDEX}])</p><p>Recovery expression: </p> | high |
Temperature on {#SNMPVALUE} to high (LLD) | <p>Temperature of the item is above Warning Level.</p> | <p>Expression: last(/SNMP-iDRAC-9/TempValue.[{#SNMPINDEX}]) > last(/SNMP-iDRAC-9/TempWarnUpLimit.[{#SNMPINDEX}]) and last(/SNMP-iDRAC-9/TempValue.[{#SNMPINDEX}]) < last(/SNMP-iDRAC-9/TempCritUpLimit.[{#SNMPINDEX}])</p><p>Recovery expression: </p> | warning |
Temperature on {#SNMPVALUE} to low (LLD) | <p>Temperature of the item is below Warning Level.</p> | <p>Expression: last(/SNMP-iDRAC-9/TempValue.[{#SNMPINDEX}]) < last(/SNMP-iDRAC-9/TempWarnLowLimit.[{#SNMPINDEX}]) and last(/SNMP-iDRAC-9/TempValue.[{#SNMPINDEX}]) > last(/SNMP-iDRAC-9/TempCritLowLimit.[{#SNMPINDEX}])</p><p>Recovery expression: </p> | warning |
{HOST.NAME}: Volume {#SNMPINDEX} Error (LLD) | <p>-</p> | <p>Expression: (last(/SNMP-iDRAC-9/VolumeDiskState.[{#SNMPINDEX}])<>2) and (last(/SNMP-iDRAC-9/SystemPowerState)=4)</p><p>Recovery expression: </p> | high |
{HOST.NAME}: Volume {#SNMPINDEX} Status Error (LLD) | <p>-</p> | <p>Expression: (last(/SNMP-iDRAC-9/VolumeStatus.[{#SNMPINDEX}])<>3) and (last(/SNMP-iDRAC-9/SystemPowerState)=4)</p><p>Recovery expression: </p> | high |
{HOST.NAME}: Error on PSU {#SNMPINDEX} State (LLD) | <p>-</p> | <p>Expression: (last(/SNMP-iDRAC-9/PowerSupplySensorState.[{#SNMPINDEX}])<>1) and (last(/SNMP-iDRAC-9/SystemPowerState)=4)</p><p>Recovery expression: </p> | high |
{HOST.NAME}: Problem with PSU {#SNMPINDEX} (LLD) | <p>-</p> | <p>Expression: (last(/SNMP-iDRAC-9/PowerSupplyStatus.[{#SNMPINDEX}])<>3) and (last(/SNMP-iDRAC-9/SystemPowerState)=4)</p><p>Recovery expression: </p> | high |
Lucas Afonso Kremer https://www.linkedin.com/in/lucasafonsokremer
{$SNMP_COMMUNITY} with the community to be used
snmpstatus -v 2c -c public 192.168.0.1 Based on @endersonmaia iDRAC 7 template
Lucas Afonso Kremer
There are no macros links in this template.
There are no template links in this template.
Name | Description | Type | Key and additional info |
---|---|---|---|
Voltage Table Enumeration | <p>-</p> | SNMP agent |
VoltageTable<p>Update: 1d</p> |
Disk Enumeration | <p>-</p> | SNMP agent |
DiskEnumeration<p>Update: 1d</p> |
Memory Enumeration | <p>-</p> | SNMP agent |
MemoryEnum<p>Update: 1d;50s/1-7,00:00-24:00</p> |
Network Enumeration | <p>-</p> | SNMP agent |
NetworkEnum<p>Update: 1d</p> |
Processor Enumeration | <p>-</p> | SNMP agent |
ProcEnum<p>Update: 1d</p> |
Fan Enumeration | <p>-</p> | SNMP agent |
FanEnumeration<p>Update: 1d</p> |
Temperature Enumeration | <p>-</p> | SNMP agent |
TempEnum<p>Update: 1d</p> |
Disk Volume Enumeration | <p>-</p> | SNMP agent |
VolumeEnum<p>Update: 1d</p> |
Power Supply Enumeration | <p>-</p> | SNMP agent |
PowerSupplies<p>Update: 1d</p> |
Name | Description | Type | Key and additional info |
---|---|---|---|
DRAC Access URL | <p>-</p> | SNMP agent |
idrac_acessurl<p>Update: 1d</p> |
RAID Controller : Name | <p>-</p> | SNMP agent |
RAIDControllerName<p>Update: 1d</p> |
System Express Service Code | <p>-</p> | SNMP agent |
idrac_esc<p>Update: 1d</p> |
Voltage Status Combined | <p>-</p> | SNMP agent |
VoltageStatusCombined<p>Update: 10m</p> |
Overall System Power State | <p>-</p> | SNMP agent |
GlobalSystemPowerState<p>Update: 1h</p> |
RAID Controller : Firmware Version | <p>-</p> | SNMP agent |
RAIDControllerFirmware<p>Update: 1d</p> |
CMOS Battery Status | <p>-</p> | SNMP agent |
CMOSBatteryStatus<p>Update: 1h</p> |
RAID Controller : Status | <p>-</p> | SNMP agent |
RAIDControllerStatus<p>Update: 10m</p> |
BIOS Date | <p>-</p> | SNMP agent |
BiosDate<p>Update: 1d</p> |
DRAC version | <p>-</p> | SNMP agent |
idrac_version<p>Update: 1d</p> |
System BIOS Status | <p>-</p> | SNMP agent |
SystemBiosStatus<p>Update: 1h</p> |
System Power State | <p>4 server is on 3 server is on stand-by</p> | SNMP agent |
SystemPowerState<p>Update: 5m</p> |
Overall System LCD Status | <p>-</p> | SNMP agent |
GlobalSystemLCDStatus<p>Update: 1h</p> |
Power Usage Minimum Idle Power | <p>-</p> | SNMP agent |
PowerUsageMinIdle<p>Update: 1h</p> |
Overall System Storage Status | <p>-</p> | SNMP agent |
GlobalSystemStorageStatus<p>Update: 1h</p> |
System Model | <p>-</p> | SNMP agent |
idrac_SystemModel<p>Update: 1d</p> |
Overall System Status | <p>-</p> | SNMP agent |
GlobalSystemStatus<p>Update: 5m</p> |
System Asset Tag | <p>-</p> | SNMP agent |
idrac_assettag<p>Update: 1d</p> |
Power Usage Sensor Status | <p>-</p> | SNMP agent |
PowerUsageSensorStatus<p>Update: 1h</p> |
BIOS Version | <p>-</p> | SNMP agent |
BiosVersion<p>Update: 1d</p> |
DRAC Firmware version | <p>-</p> | SNMP agent |
idrac_firmwareversion<p>Update: 1d</p> |
Voltage : {#SNMPVALUE} Status | <p>-</p> | SNMP agent |
VoltageStatus.[{#SNMPINDEX}]<p>Update: 10m</p><p>LLD</p> |
Disk {#SNMPINDEX} : Manufacture Day | <p>-</p> | SNMP agent |
DiskManufactureDay.[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p> |
Disk {#SNMPINDEX} : Manufacturer | <p>-</p> | SNMP agent |
DiskManufacturer.[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p> |
Disk {#SNMPINDEX} : Manufacture Week | <p>-</p> | SNMP agent |
DiskManufactureWeek.[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p> |
Disk {#SNMPINDEX} : Manufacture Year | <p>-</p> | SNMP agent |
DiskManufactureYear.[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p> |
Disk {#SNMPINDEX} : Model Number | <p>-</p> | SNMP agent |
DiskModel.[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p> |
Disk {#SNMPINDEX} : Name | <p>-</p> | SNMP agent |
DiskName.[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p> |
Disk {#SNMPINDEX} : Serial Number | <p>-</p> | SNMP agent |
DiskSerialNo.[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p> |
Disk {#SNMPINDEX} : Disk Size | <p>-</p> | SNMP agent |
DiskSize.[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p> |
Disk {#SNMPINDEX} : Disk State | <p>-</p> | SNMP agent |
DiskState.[{#SNMPINDEX}]<p>Update: 1h</p><p>LLD</p> |
Disk {#SNMPINDEX} : Disk Status | <p>-</p> | SNMP agent |
DiskStatus.[{#SNMPINDEX}]<p>Update: 1h</p><p>LLD</p> |
Memory Slot {#SNMPVALUE} Manufacturer | <p>-</p> | SNMP agent |
MemManufacturer[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p> |
Memory Slot {#SNMPVALUE} Part Number | <p>-</p> | SNMP agent |
MemPartlNo.[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p> |
Memory Slot {#SNMPVALUE} Serial Number | <p>-</p> | SNMP agent |
MemSerialNo.[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p> |
Memory Slot {#SNMPVALUE} Size | <p>-</p> | SNMP agent |
MemSize.[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p> |
Memory Slot {#SNMPVALUE} Speed | <p>-</p> | SNMP agent |
MemSpeed.[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p> |
Memory Slot {#SNMPVALUE} Status | <p>-</p> | SNMP agent |
MemStatus.[{#SNMPINDEX}]<p>Update: 30m</p><p>LLD</p> |
NIC {#SNMPINDEX} : Connection Status | <p>-</p> | SNMP agent |
NetConnStatus.[{#SNMPINDEX}]<p>Update: 10m</p><p>LLD</p> |
NIC {#SNMPINDEX} : MAC Address | <p>-</p> | SNMP agent |
NetMAC.[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p> |
NIC {#SNMPINDEX} : Name | <p>-</p> | SNMP agent |
NetName.[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p> |
NIC {#SNMPINDEX} : Slot | <p>-</p> | SNMP agent |
NetSlot.[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p> |
NIC {#SNMPINDEX} : Status | <p>-</p> | SNMP agent |
NetStatus.[{#SNMPINDEX}]<p>Update: 5m</p><p>LLD</p> |
Processor {#SNMPINDEX} Status | <p>-</p> | SNMP agent |
ProcStatus.[{#SNMPINDEX}]<p>Update: 5m</p><p>LLD</p> |
Fan {#SNMPVALUE} Speed | <p>-</p> | SNMP agent |
FanSpeed.[{#SNMPINDEX}]<p>Update: 5m</p><p>LLD</p> |
Fan {#SNMPVALUE} Status | <p>-</p> | SNMP agent |
FanStatus.[{#SNMPINDEX}]<p>Update: 5m</p><p>LLD</p> |
Temperature Sensor {#SNMPVALUE} Critical Low-Limit | <p>-</p> | SNMP agent |
TempCritLowLimit.[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p> |
Temperature Sensor {#SNMPVALUE} Critical Up-Limit | <p>-</p> | SNMP agent |
TempCritUpLimit.[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p> |
Temperature Sensor {#SNMPVALUE} Status | <p>-</p> | SNMP agent |
TempStatus.[{#SNMPINDEX}]<p>Update: 5m</p><p>LLD</p> |
Temperature Sensor {#SNMPVALUE} Value | <p>-</p> | SNMP agent |
TempValue.[{#SNMPINDEX}]<p>Update: 5m</p><p>LLD</p> |
Temperature Sensor {#SNMPVALUE} Warning Low-Limit | <p>-</p> | SNMP agent |
TempWarnLowLimit.[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p> |
Temperature Sensor {#SNMPVALUE} Warning Up-Limit | <p>-</p> | SNMP agent |
TempWarnUpLimit.[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p> |
Volume {#SNMPINDEX} : Virtual Disk State | <p>-</p> | SNMP agent |
VolumeDiskState.[{#SNMPINDEX}]<p>Update: 1h</p><p>LLD</p> |
Volume {#SNMPINDEX} : Name | <p>-</p> | SNMP agent |
VolumeName.[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p> |
Volume {#SNMPINDEX} : Size | <p>-</p> | SNMP agent |
VolumeSize.[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p> |
Volume {#SNMPINDEX} : State | <p>-</p> | SNMP agent |
VolumeState.[{#SNMPINDEX}]<p>Update: 1h</p><p>LLD</p> |
Volume {#SNMPINDEX} : Status | <p>-</p> | SNMP agent |
VolumeStatus.[{#SNMPINDEX}]<p>Update: 1h</p><p>LLD</p> |
Power Supply {#SNMPINDEX} Input Voltage | <p>-</p> | SNMP agent |
PowerSupplyInputVoltage.[{#SNMPINDEX}]<p>Update: 5m</p><p>LLD</p> |
Power Supply {#SNMPINDEX} Maximum Power | <p>-</p> | SNMP agent |
PowerSupplyMaxPower.[{#SNMPINDEX}]<p>Update: 1d</p><p>LLD</p> |
Power Supply {#SNMPINDEX} Sensor State | <p>-</p> | SNMP agent |
PowerSupplySensorState.[{#SNMPINDEX}]<p>Update: 10m</p><p>LLD</p> |
Power Supply {#SNMPINDEX} State Settings | <p>-</p> | SNMP agent |
PowerSupplyStateSettings.[{#SNMPINDEX}]<p>Update: 10m</p><p>LLD</p> |
Power Supply {#SNMPINDEX} Status | <p>-</p> | SNMP agent |
PowerSupplyStatus.[{#SNMPINDEX}]<p>Update: 5m</p><p>LLD</p> |
Name | Description | Expression | Priority |
---|---|---|---|
{HOST.NAME}: Problem with Disk {#SNMPINDEX} | <p>-</p> | <p>Expression: (last(/SNMP-iDRAC-9/DiskStatus.[{#SNMPINDEX}])<>3) and (last(/SNMP-iDRAC-9/SystemPowerState)=4)</p><p>Recovery expression: </p> | disaster |
{HOST.NAME}: Problem with FAN {#SNMPVALUE} | <p>-</p> | <p>Expression: (last(/SNMP-iDRAC-9/FanStatus.[{#SNMPINDEX}])<>3) and (last(/SNMP-iDRAC-9/SystemPowerState)=4)</p><p>Recovery expression: </p> | average |
{HOST.NAME}: Problem with memory in slot {#SNMPVALUE} | <p>-</p> | <p>Expression: (last(/SNMP-iDRAC-9/MemStatus.[{#SNMPINDEX}])<>3) and (last(/SNMP-iDRAC-9/SystemPowerState)=4)</p><p>Recovery expression: </p> | high |
{HOST.NAME}: Error on NIC {#SNMPINDEX} | <p>-</p> | <p>Expression: (last(/SNMP-iDRAC-9/NetStatus.[{#SNMPINDEX}])<>3) and (last(/SNMP-iDRAC-9/SystemPowerState)=4)</p><p>Recovery expression: </p> | disaster |
{HOST.NAME}: Error on PSU {#SNMPINDEX} State | <p>-</p> | <p>Expression: (last(/SNMP-iDRAC-9/PowerSupplySensorState.[{#SNMPINDEX}])<>1) and (last(/SNMP-iDRAC-9/SystemPowerState)=4)</p><p>Recovery expression: </p> | high |
{HOST.NAME}: Problem with PSU {#SNMPINDEX} | <p>-</p> | <p>Expression: (last(/SNMP-iDRAC-9/PowerSupplyStatus.[{#SNMPINDEX}])<>3) and (last(/SNMP-iDRAC-9/SystemPowerState)=4)</p><p>Recovery expression: </p> | high |
{HOST.NAME}: Error on Processor {#SNMPINDEX} | <p>-</p> | <p>Expression: (last(/SNMP-iDRAC-9/ProcStatus.[{#SNMPINDEX}])<>3) and (last(/SNMP-iDRAC-9/ProcStatus.[{#SNMPINDEX}])<>2) and (last(/SNMP-iDRAC-9/SystemPowerState)=4)</p><p>Recovery expression: </p> | disaster |
Problem with Temperature Sensor {#SNMPVALUE} | <p>-</p> | <p>Expression: last(/SNMP-iDRAC-9/TempStatus.[{#SNMPINDEX}])<>3</p><p>Recovery expression: </p> | warning |
Temperature on {#SNMPVALUE} critically high | <p>Temperature of the item is above Critical Level.</p> | <p>Expression: last(/SNMP-iDRAC-9/TempValue.[{#SNMPINDEX}]) >= last(/SNMP-iDRAC-9/TempCritUpLimit.[{#SNMPINDEX}])</p><p>Recovery expression: </p> | high |
Temperature on {#SNMPVALUE} critically low | <p>Temperature of the item is below Critical Level.</p> | <p>Expression: last(/SNMP-iDRAC-9/TempValue.[{#SNMPINDEX}]) <= last(/SNMP-iDRAC-9/TempCritLowLimit.[{#SNMPINDEX}])</p><p>Recovery expression: </p> | high |
Temperature on {#SNMPVALUE} to high | <p>Temperature of the item is above Warning Level.</p> | <p>Expression: last(/SNMP-iDRAC-9/TempValue.[{#SNMPINDEX}]) > last(/SNMP-iDRAC-9/TempWarnUpLimit.[{#SNMPINDEX}]) and last(/SNMP-iDRAC-9/TempValue.[{#SNMPINDEX}]) < last(/SNMP-iDRAC-9/TempCritUpLimit.[{#SNMPINDEX}])</p><p>Recovery expression: </p> | warning |
Temperature on {#SNMPVALUE} to low | <p>Temperature of the item is below Warning Level.</p> | <p>Expression: last(/SNMP-iDRAC-9/TempValue.[{#SNMPINDEX}]) < last(/SNMP-iDRAC-9/TempWarnLowLimit.[{#SNMPINDEX}]) and last(/SNMP-iDRAC-9/TempValue.[{#SNMPINDEX}]) > last(/SNMP-iDRAC-9/TempCritLowLimit.[{#SNMPINDEX}])</p><p>Recovery expression: </p> | warning |
{HOST.NAME}: Error on Voltage Sensor {#SNMPVALUE} | <p>-</p> | <p>Expression: (last(/SNMP-iDRAC-9/VoltageStatus.[{#SNMPINDEX}])<>3) and (last(/SNMP-iDRAC-9/SystemPowerState)=4)</p><p>Recovery expression: </p> | average |
{HOST.NAME}: Volume {#SNMPINDEX} Error | <p>-</p> | <p>Expression: (last(/SNMP-iDRAC-9/VolumeDiskState.[{#SNMPINDEX}])<>2) and (last(/SNMP-iDRAC-9/SystemPowerState)=4)</p><p>Recovery expression: </p> | high |
{HOST.NAME}: Volume {#SNMPINDEX} Status Error | <p>-</p> | <p>Expression: (last(/SNMP-iDRAC-9/VolumeStatus.[{#SNMPINDEX}])<>3) and (last(/SNMP-iDRAC-9/SystemPowerState)=4)</p><p>Recovery expression: </p> | high |
{HOST.NAME}: Error on Voltage Sensor {#SNMPVALUE} (LLD) | <p>-</p> | <p>Expression: (last(/SNMP-iDRAC-9/VoltageStatus.[{#SNMPINDEX}])<>3) and (last(/SNMP-iDRAC-9/SystemPowerState)=4)</p><p>Recovery expression: </p> | average |
{HOST.NAME}: Problem with Disk {#SNMPINDEX} (LLD) | <p>-</p> | <p>Expression: (last(/SNMP-iDRAC-9/DiskStatus.[{#SNMPINDEX}])<>3) and (last(/SNMP-iDRAC-9/SystemPowerState)=4)</p><p>Recovery expression: </p> | disaster |
{HOST.NAME}: Problem with memory in slot {#SNMPVALUE} (LLD) | <p>-</p> | <p>Expression: (last(/SNMP-iDRAC-9/MemStatus.[{#SNMPINDEX}])<>3) and (last(/SNMP-iDRAC-9/SystemPowerState)=4)</p><p>Recovery expression: </p> | high |
{HOST.NAME}: Error on NIC {#SNMPINDEX} (LLD) | <p>-</p> | <p>Expression: (last(/SNMP-iDRAC-9/NetStatus.[{#SNMPINDEX}])<>3) and (last(/SNMP-iDRAC-9/SystemPowerState)=4)</p><p>Recovery expression: </p> | disaster |
{HOST.NAME}: Error on Processor {#SNMPINDEX} (LLD) | <p>-</p> | <p>Expression: (last(/SNMP-iDRAC-9/ProcStatus.[{#SNMPINDEX}])<>3) and (last(/SNMP-iDRAC-9/ProcStatus.[{#SNMPINDEX}])<>2) and (last(/SNMP-iDRAC-9/SystemPowerState)=4)</p><p>Recovery expression: </p> | disaster |
{HOST.NAME}: Problem with FAN {#SNMPVALUE} (LLD) | <p>-</p> | <p>Expression: (last(/SNMP-iDRAC-9/FanStatus.[{#SNMPINDEX}])<>3) and (last(/SNMP-iDRAC-9/SystemPowerState)=4)</p><p>Recovery expression: </p> | average |
Problem with Temperature Sensor {#SNMPVALUE} (LLD) | <p>-</p> | <p>Expression: last(/SNMP-iDRAC-9/TempStatus.[{#SNMPINDEX}])<>3</p><p>Recovery expression: </p> | warning |
Temperature on {#SNMPVALUE} critically high (LLD) | <p>Temperature of the item is above Critical Level.</p> | <p>Expression: last(/SNMP-iDRAC-9/TempValue.[{#SNMPINDEX}]) >= last(/SNMP-iDRAC-9/TempCritUpLimit.[{#SNMPINDEX}])</p><p>Recovery expression: </p> | high |
Temperature on {#SNMPVALUE} critically low (LLD) | <p>Temperature of the item is below Critical Level.</p> | <p>Expression: last(/SNMP-iDRAC-9/TempValue.[{#SNMPINDEX}]) <= last(/SNMP-iDRAC-9/TempCritLowLimit.[{#SNMPINDEX}])</p><p>Recovery expression: </p> | high |
Temperature on {#SNMPVALUE} to high (LLD) | <p>Temperature of the item is above Warning Level.</p> | <p>Expression: last(/SNMP-iDRAC-9/TempValue.[{#SNMPINDEX}]) > last(/SNMP-iDRAC-9/TempWarnUpLimit.[{#SNMPINDEX}]) and last(/SNMP-iDRAC-9/TempValue.[{#SNMPINDEX}]) < last(/SNMP-iDRAC-9/TempCritUpLimit.[{#SNMPINDEX}])</p><p>Recovery expression: </p> | warning |
Temperature on {#SNMPVALUE} to low (LLD) | <p>Temperature of the item is below Warning Level.</p> | <p>Expression: last(/SNMP-iDRAC-9/TempValue.[{#SNMPINDEX}]) < last(/SNMP-iDRAC-9/TempWarnLowLimit.[{#SNMPINDEX}]) and last(/SNMP-iDRAC-9/TempValue.[{#SNMPINDEX}]) > last(/SNMP-iDRAC-9/TempCritLowLimit.[{#SNMPINDEX}])</p><p>Recovery expression: </p> | warning |
{HOST.NAME}: Volume {#SNMPINDEX} Error (LLD) | <p>-</p> | <p>Expression: (last(/SNMP-iDRAC-9/VolumeDiskState.[{#SNMPINDEX}])<>2) and (last(/SNMP-iDRAC-9/SystemPowerState)=4)</p><p>Recovery expression: </p> | high |
{HOST.NAME}: Volume {#SNMPINDEX} Status Error (LLD) | <p>-</p> | <p>Expression: (last(/SNMP-iDRAC-9/VolumeStatus.[{#SNMPINDEX}])<>3) and (last(/SNMP-iDRAC-9/SystemPowerState)=4)</p><p>Recovery expression: </p> | high |
{HOST.NAME}: Error on PSU {#SNMPINDEX} State (LLD) | <p>-</p> | <p>Expression: (last(/SNMP-iDRAC-9/PowerSupplySensorState.[{#SNMPINDEX}])<>1) and (last(/SNMP-iDRAC-9/SystemPowerState)=4)</p><p>Recovery expression: </p> | high |
{HOST.NAME}: Problem with PSU {#SNMPINDEX} (LLD) | <p>-</p> | <p>Expression: (last(/SNMP-iDRAC-9/PowerSupplyStatus.[{#SNMPINDEX}])<>3) and (last(/SNMP-iDRAC-9/SystemPowerState)=4)</p><p>Recovery expression: </p> | high |