Available versions




Brother Printers

Overview

Termplate para monitoramento de impressoras Brother.

Testado nos modelos 8912DW e HL5452.

Author

Fernando Lozer

Macros used

There are no macros links in this template.

There are no template links in this template.

Discovery rules

Name Description Type Key and additional info
Consumables <p>-</p> SNMP agent consumablesID<p>Update: 60</p>

Items collected

Name Description Type Key and additional info
Contador de Páginas <p>-</p> SNMP agent .1.3.6.1.2.1.43.10.2.1.4.1.1<p>Update: 3600</p>
JetDirect Check <p>-</p> Simple check net.tcp.service[tcp,,9100]<p>Update: 30</p>
Print Spooler Check <p>-</p> Simple check net.tcp.service[tcp,,515]<p>Update: 30</p>
Número de Série <p>-</p> SNMP agent .1.3.6.1.2.1.43.5.1.1.17.1<p>Update: 3600</p>
Localização <p>-</p> SNMP agent sysLocation.0<p>Update: 3600</p>
HTTP Check <p>-</p> Simple check net.tcp.service[http]<p>Update: 30</p>
Vida Útil restante do Cilindro <p>-</p> SNMP agent .1.3.6.1.2.1.43.11.1.1.9.1.2<p>Update: 3600</p>
Status do Equipamento <p>-</p> SNMP agent .1.3.6.1.2.1.43.18.1.1.8.1.1<p>Update: 3600</p>
Contato <p>-</p> SNMP agent sysContact.0<p>Update: 3600</p>
Modelo <p>-</p> SNMP agent hrDeviceDescr.1<p>Update: 3600</p>
$1 Current Capacity <p>-</p> SNMP agent ConsumableCurrentCapacity[{#SNMPVALUE}]<p>Update: 30</p><p>LLD</p>
$1 Max Capacity <p>-</p> SNMP agent ConsumableMaxCapacity[{#SNMPVALUE}]<p>Update: 30</p><p>LLD</p>
$1 Calculated Capacity (current/max) <p>Depending on the consumable (toner vs drum/belt) this calculation will return a particular percentage. Drum Units & Belt Units return integer values that can be used in calculations to determine a percentage of how much of the unit is remaining. Max “status” is stored in the MIB and is used in the calculation. Toner consumables return the follow codes: -3 = Level Okay -2 = Low Warning (equivalent to “max status”) 0 = Critical/empty Toner possibilities for calculations of current / max * 100 -3 / -2 * 100 = 150% -2 / -2 * 100 = 100% 0 / -2 * 100 = 0% The calculations above are used in the triggers to make it very straight forward on determining if a toner is low or not.</p> Calculated CosumableCalculated[{#SNMPVALUE}]<p>Update: 30</p><p>LLD</p>

Triggers

Name Description Expression Priority
{HOSTNAME} {#SNMPVALUE} - Critical: {ITEM.LASTVALUE} <p>Checks if at “critical” level for Toners (code = 0) or drum/belt (<10%)</p> <p>Expression: {Brother Printers:CosumableCalculated[{#SNMPVALUE}].last(0)}<10 or {Brother Printers:ConsumableCurrentCapacity[{#SNMPVALUE}].last(0)}=0</p><p>Recovery expression: </p> high
{HOSTNAME} {#SNMPVALUE} - Low Warning: {ITEM.LASTVALUE} <p>Checks if at “warning” level for Toners (code = -2) or drum/belt (>10% & <30%)</p> <p>Expression: {Brother Printers:CosumableCalculated[{#SNMPVALUE}].last(0)}>10 and {Brother Printers:CosumableCalculated[{#SNMPVALUE}].last(0)}<30 or {Brother Printers:ConsumableCurrentCapacity[{#SNMPVALUE}].last(0)} = -2</p><p>Recovery expression: </p> warning
{HOSTNAME} {#SNMPVALUE} - Critical: {ITEM.LASTVALUE} (LLD) <p>Checks if at “critical” level for Toners (code = 0) or drum/belt (<10%)</p> <p>Expression: {Brother Printers:CosumableCalculated[{#SNMPVALUE}].last(0)}<10 or {Brother Printers:ConsumableCurrentCapacity[{#SNMPVALUE}].last(0)}=0</p><p>Recovery expression: </p> high
{HOSTNAME} {#SNMPVALUE} - Low Warning: {ITEM.LASTVALUE} (LLD) <p>Checks if at “warning” level for Toners (code = -2) or drum/belt (>10% & <30%)</p> <p>Expression: {Brother Printers:CosumableCalculated[{#SNMPVALUE}].last(0)}>10 and {Brother Printers:CosumableCalculated[{#SNMPVALUE}].last(0)}<30 or {Brother Printers:ConsumableCurrentCapacity[{#SNMPVALUE}].last(0)} = -2</p><p>Recovery expression: </p> warning

Brother Printers

Overview

Termplate para monitoramento de impressoras Brother.

Testado nos modelos 8912DW e HL5452.

Author

Fernando Lozer

Macros used

There are no macros links in this template.

There are no template links in this template.

Discovery rules

Name Description Type Key and additional info
Consumables <p>-</p> SNMP agent consumablesID<p>Update: 60</p>

Items collected

Name Description Type Key and additional info
Vida Útil restante do Cilindro <p>-</p> SNMP agent .1.3.6.1.2.1.43.11.1.1.9.1.2<p>Update: 3600</p>
HTTP Check <p>-</p> Simple check net.tcp.service[http]<p>Update: 30</p>
Localização <p>-</p> SNMP agent sysLocation.0<p>Update: 3600</p>
Contato <p>-</p> SNMP agent sysContact.0<p>Update: 3600</p>
Contador de Páginas <p>-</p> SNMP agent .1.3.6.1.2.1.43.10.2.1.4.1.1<p>Update: 3600</p>
Número de Série <p>-</p> SNMP agent .1.3.6.1.2.1.43.5.1.1.17.1<p>Update: 3600</p>
Status do Equipamento <p>-</p> SNMP agent .1.3.6.1.2.1.43.18.1.1.8.1.1<p>Update: 3600</p>
Modelo <p>-</p> SNMP agent hrDeviceDescr.1<p>Update: 3600</p>
Print Spooler Check <p>-</p> Simple check net.tcp.service[tcp,,515]<p>Update: 30</p>
JetDirect Check <p>-</p> Simple check net.tcp.service[tcp,,9100]<p>Update: 30</p>
$1 Current Capacity <p>-</p> SNMP agent ConsumableCurrentCapacity[{#SNMPVALUE}]<p>Update: 30</p><p>LLD</p>
$1 Max Capacity <p>-</p> SNMP agent ConsumableMaxCapacity[{#SNMPVALUE}]<p>Update: 30</p><p>LLD</p>
$1 Calculated Capacity (current/max) <p>Depending on the consumable (toner vs drum/belt) this calculation will return a particular percentage. Drum Units & Belt Units return integer values that can be used in calculations to determine a percentage of how much of the unit is remaining. Max “status” is stored in the MIB and is used in the calculation. Toner consumables return the follow codes: -3 = Level Okay -2 = Low Warning (equivalent to “max status”) 0 = Critical/empty Toner possibilities for calculations of current / max * 100 -3 / -2 * 100 = 150% -2 / -2 * 100 = 100% 0 / -2 * 100 = 0% The calculations above are used in the triggers to make it very straight forward on determining if a toner is low or not.</p> Calculated CosumableCalculated[{#SNMPVALUE}]<p>Update: 30</p><p>LLD</p>

Triggers

Name Description Expression Priority
{HOSTNAME} {#SNMPVALUE} - Critical: {ITEM.LASTVALUE} <p>Checks if at “critical” level for Toners (code = 0) or drum/belt (<10%)</p> <p>Expression: last(/Brother Printers/CosumableCalculated[{#SNMPVALUE}])<10 or last(/Brother Printers/ConsumableCurrentCapacity[{#SNMPVALUE}])=0</p><p>Recovery expression: </p> high
{HOSTNAME} {#SNMPVALUE} - Low Warning: {ITEM.LASTVALUE} <p>Checks if at “warning” level for Toners (code = -2) or drum/belt (>10% & <30%)</p> <p>Expression: last(/Brother Printers/CosumableCalculated[{#SNMPVALUE}])>10 and last(/Brother Printers/CosumableCalculated[{#SNMPVALUE}])<30 or last(/Brother Printers/ConsumableCurrentCapacity[{#SNMPVALUE}]) = -2</p><p>Recovery expression: </p> warning
{HOSTNAME} {#SNMPVALUE} - Critical: {ITEM.LASTVALUE} (LLD) <p>Checks if at “critical” level for Toners (code = 0) or drum/belt (<10%)</p> <p>Expression: last(/Brother Printers/CosumableCalculated[{#SNMPVALUE}])<10 or last(/Brother Printers/ConsumableCurrentCapacity[{#SNMPVALUE}])=0</p><p>Recovery expression: </p> high
{HOSTNAME} {#SNMPVALUE} - Low Warning: {ITEM.LASTVALUE} (LLD) <p>Checks if at “warning” level for Toners (code = -2) or drum/belt (>10% & <30%)</p> <p>Expression: last(/Brother Printers/CosumableCalculated[{#SNMPVALUE}])>10 and last(/Brother Printers/CosumableCalculated[{#SNMPVALUE}])<30 or last(/Brother Printers/ConsumableCurrentCapacity[{#SNMPVALUE}]) = -2</p><p>Recovery expression: </p> warning

Brother Printers

Overview

Termplate para monitoramento de impressoras Brother.

Testado nos modelos 8912DW e HL5452.

Author

Fernando Lozer

Macros used

There are no macros links in this template.

There are no template links in this template.

Discovery rules

Name Description Type Key and additional info
Consumables <p>-</p> SNMP agent consumablesID<p>Update: 60</p>

Items collected

Name Description Type Key and additional info
Vida Útil restante do Cilindro <p>-</p> SNMP agent .1.3.6.1.2.1.43.11.1.1.9.1.2<p>Update: 3600</p>
HTTP Check <p>-</p> Simple check net.tcp.service[http]<p>Update: 30</p>
Localização <p>-</p> SNMP agent sysLocation.0<p>Update: 3600</p>
Contato <p>-</p> SNMP agent sysContact.0<p>Update: 3600</p>
Contador de Páginas <p>-</p> SNMP agent .1.3.6.1.2.1.43.10.2.1.4.1.1<p>Update: 3600</p>
Número de Série <p>-</p> SNMP agent .1.3.6.1.2.1.43.5.1.1.17.1<p>Update: 3600</p>
Status do Equipamento <p>-</p> SNMP agent .1.3.6.1.2.1.43.18.1.1.8.1.1<p>Update: 3600</p>
Modelo <p>-</p> SNMP agent hrDeviceDescr.1<p>Update: 3600</p>
Print Spooler Check <p>-</p> Simple check net.tcp.service[tcp,,515]<p>Update: 30</p>
JetDirect Check <p>-</p> Simple check net.tcp.service[tcp,,9100]<p>Update: 30</p>
$1 Current Capacity <p>-</p> SNMP agent ConsumableCurrentCapacity[{#SNMPVALUE}]<p>Update: 30</p><p>LLD</p>
$1 Max Capacity <p>-</p> SNMP agent ConsumableMaxCapacity[{#SNMPVALUE}]<p>Update: 30</p><p>LLD</p>
$1 Calculated Capacity (current/max) <p>Depending on the consumable (toner vs drum/belt) this calculation will return a particular percentage. Drum Units & Belt Units return integer values that can be used in calculations to determine a percentage of how much of the unit is remaining. Max “status” is stored in the MIB and is used in the calculation. Toner consumables return the follow codes: -3 = Level Okay -2 = Low Warning (equivalent to “max status”) 0 = Critical/empty Toner possibilities for calculations of current / max * 100 -3 / -2 * 100 = 150% -2 / -2 * 100 = 100% 0 / -2 * 100 = 0% The calculations above are used in the triggers to make it very straight forward on determining if a toner is low or not.</p> Calculated CosumableCalculated[{#SNMPVALUE}]<p>Update: 30</p><p>LLD</p>

Triggers

Name Description Expression Priority
{HOSTNAME} {#SNMPVALUE} - Critical: {ITEM.LASTVALUE} <p>Checks if at “critical” level for Toners (code = 0) or drum/belt (<10%)</p> <p>Expression: last(/Brother Printers/CosumableCalculated[{#SNMPVALUE}])<10 or last(/Brother Printers/ConsumableCurrentCapacity[{#SNMPVALUE}])=0</p><p>Recovery expression: </p> high
{HOSTNAME} {#SNMPVALUE} - Low Warning: {ITEM.LASTVALUE} <p>Checks if at “warning” level for Toners (code = -2) or drum/belt (>10% & <30%)</p> <p>Expression: last(/Brother Printers/CosumableCalculated[{#SNMPVALUE}])>10 and last(/Brother Printers/CosumableCalculated[{#SNMPVALUE}])<30 or last(/Brother Printers/ConsumableCurrentCapacity[{#SNMPVALUE}]) = -2</p><p>Recovery expression: </p> warning
{HOSTNAME} {#SNMPVALUE} - Critical: {ITEM.LASTVALUE} (LLD) <p>Checks if at “critical” level for Toners (code = 0) or drum/belt (<10%)</p> <p>Expression: last(/Brother Printers/CosumableCalculated[{#SNMPVALUE}])<10 or last(/Brother Printers/ConsumableCurrentCapacity[{#SNMPVALUE}])=0</p><p>Recovery expression: </p> high
{HOSTNAME} {#SNMPVALUE} - Low Warning: {ITEM.LASTVALUE} (LLD) <p>Checks if at “warning” level for Toners (code = -2) or drum/belt (>10% & <30%)</p> <p>Expression: last(/Brother Printers/CosumableCalculated[{#SNMPVALUE}])>10 and last(/Brother Printers/CosumableCalculated[{#SNMPVALUE}])<30 or last(/Brother Printers/ConsumableCurrentCapacity[{#SNMPVALUE}]) = -2</p><p>Recovery expression: </p> warning