Делал под Thecus N8900
Чтобы нормально получать данные через SNMP ставьте последние прошивки на устройства.
В принципе моя модель - это linux NAS. Через linux SNMPv2 практически все выдается, но в самой
морде есть mib-файл, на его основе и сделал данный шаблон.
Вопросы на 2135850@211.ru
S.V.Sidenko
Name | Description | Default | Type |
---|---|---|---|
{$HD_TEMPERATURE_ALARM} | <p>-</p> | 51 |
Text macro |
{$HD_TEMPERATURE_WARNING} | <p>-</p> | 40 |
Text macro |
{$SNMP_PORT} | <p>-</p> | 161 |
Text macro |
There are no template links in this template.
Name | Description | Type | Key and additional info |
---|---|---|---|
RAID discovery | <p>-</p> | SNMP agent |
nasRaid.discovery<p>Update: 1h</p> |
Hard disks discovery | <p>-</p> | SNMP agent |
nasDisk.discovery<p>Update: 1h</p> |
Name | Description | Type | Key and additional info |
---|---|---|---|
System fan status | <p>-</p> | SNMP agent |
systemFanStatus<p>Update: 60</p> |
System status | <p>-</p> | SNMP agent |
systemStatus<p>Update: 60</p> |
System vendor | <p>-</p> | SNMP agent |
systemVendor<p>Update: 3h</p> |
System Mini-UPS Status | <p>-</p> | SNMP agent |
systemMiniUPSStatus<p>Update: 60</p> |
System firmware | <p>-</p> | SNMP agent |
systemFirmware<p>Update: 3h</p> |
System model | <p>-</p> | SNMP agent |
systemModel<p>Update: 3h</p> |
System temperature | <p>System temperature in centigrade</p> | SNMP agent |
systemTemperature<p>Update: 60</p> |
RAID ID of {#SNMPVALUE} | <p>-</p> | SNMP agent |
raidID[{#SNMPINDEX}]<p>Update: 3h</p><p>LLD</p> |
RAID level of {#SNMPVALUE} | <p>-</p> | SNMP agent |
raidLevel[{#SNMPINDEX}]<p>Update: 3h</p><p>LLD</p> |
RAID number of {#SNMPVALUE} | <p>-</p> | SNMP agent |
raidNum[{#SNMPINDEX}]<p>Update: 3h</p><p>LLD</p> |
RAID size of {#SNMPVALUE} | <p>-</p> | SNMP agent |
raidSize[{#SNMPINDEX}]<p>Update: 1h</p><p>LLD</p> |
RAID status of {#SNMPVALUE} | <p>-</p> | SNMP agent |
raidStatus[{#SNMPINDEX}]<p>Update: 60</p><p>LLD</p> |
RAID units of {#SNMPVALUE} | <p>-</p> | SNMP agent |
raidUnits[{#SNMPINDEX}]<p>Update: 3h</p><p>LLD</p> |
RAID used percent of {#SNMPVALUE} (%) | <p>-</p> | SNMP agent |
raidUsedPercentage[{#SNMPINDEX}]<p>Update: 1h</p><p>LLD</p> |
Disk Capacity {#SNMPVALUE} | <p>-</p> | SNMP agent |
diskCapacity[{#SNMPINDEX}]<p>Update: 1h</p><p>LLD</p> |
Disk ID {#SNMPVALUE} | <p>-</p> | SNMP agent |
diskID[{#SNMPINDEX}]<p>Update: 3h</p><p>LLD</p> |
Model of {#SNMPVALUE} | <p>-</p> | SNMP agent |
diskModel[{#SNMPINDEX}]<p>Update: 3h</p><p>LLD</p> |
Reallocate_Sector_Ct {#SNMPVALUE} | <p>-</p> | SNMP agent |
diskSMARTAttr5[{#SNMPINDEX}]<p>Update: 60</p><p>LLD</p> |
Power_On_hours{#SNMPVALUE} | <p>-</p> | SNMP agent |
diskSMARTAttr9[{#SNMPINDEX}]<p>Update: 60</p><p>LLD</p> |
End-to-End Error {#SNMPVALUE} | <p>-</p> | SNMP agent |
diskSMARTAttr184[{#SNMPINDEX}]<p>Update: 60</p><p>LLD</p> |
Temperature of {#SNMPVALUE} | <p>-</p> | SNMP agent |
diskSMARTAttr194[{#SNMPINDEX}]<p>Update: 60</p><p>LLD</p> |
Current__Pending_Sector {#SNMPVALUE} | <p>-</p> | SNMP agent |
diskSMARTAttr197[{#SNMPINDEX}]<p>Update: 60</p><p>LLD</p> |
S.M.A.R.T. info of {#SNMPVALUE} | <p>-</p> | SNMP agent |
diskSMARTHealthCheck[{#SNMPINDEX}]<p>Update: 60</p><p>LLD</p> |
Status of {#SNMPVALUE} | <p>-</p> | SNMP agent |
diskStatus[{#SNMPINDEX}]<p>Update: 60</p><p>LLD</p> |
Disk Tray Number {#SNMPVALUE} | <p>-</p> | SNMP agent |
diskTrayNum[{#SNMPINDEX}]<p>Update: 3h</p><p>LLD</p> |
Name | Description | Expression | Priority |
---|---|---|---|
State of {#SNMPVALUE} on {HOST.NAME} is “Current Pending Sector” | <p>-</p> | <p>Expression: {SNMP THECUS NAS:diskSMARTAttr197[{#SNMPINDEX}].last(0)}>0</p><p>Recovery expression: </p> | average |
State of {#SNMPVALUE} on {HOST.NAME} is “End-to-End Error” | <p>State “noDisk”</p> | <p>Expression: {SNMP THECUS NAS:diskSMARTAttr184[{#SNMPINDEX}].last(0)}>0</p><p>Recovery expression: </p> | average |
State of {#SNMPVALUE} on {HOST.NAME} is “Reallocated_Sector_Ct” | <p>State “rwError”</p> | <p>Expression: {SNMP THECUS NAS:diskSMARTAttr5[{#SNMPINDEX}].last(0)}>0</p><p>Recovery expression: </p> | average |
State of {#SNMPVALUE} on {HOST.NAME} is not “Ready” ({ITEM.VALUE1}) | <p>-</p> | <p>Expression: {SNMP THECUS NAS:diskStatus[{#SNMPINDEX}].last(0)}=3</p><p>Recovery expression: </p> | high |
Temperature of {#SNMPVALUE} on {HOST.NAME} is over {$HD_TEMPERATURE_ALARM} for 2 min | <p>-</p> | <p>Expression: {SNMP THECUS NAS:diskSMARTAttr194[{#SNMPINDEX}].min(2m)}>51</p><p>Recovery expression: </p> | high |
Temperature of {#SNMPVALUE} on {HOST.NAME} is over {$HD_TEMPERATURE_WARNING} for 2min | <p>-</p> | <p>Expression: {SNMP THECUS NAS:diskSMARTAttr194[{#SNMPINDEX}].min(2m)}>40</p><p>Recovery expression: </p> | information |
Free space is less than 5% on volume {#SNMPVALUE} | <p>-</p> | <p>Expression: {SNMP THECUS NAS:raidUsedPercentage[{#SNMPINDEX}].last(0)}>95</p><p>Recovery expression: </p> | high |
Free space is less than 10% on volume {#SNMPVALUE} | <p>-</p> | <p>Expression: {SNMP THECUS NAS:raidUsedPercentage[{#SNMPINDEX}].last(0)}>90</p><p>Recovery expression: </p> | warning |
Free space is less than 20% on volume {#SNMPVALUE} | <p>-</p> | <p>Expression: {SNMP THECUS NAS:raidUsedPercentage[{#SNMPINDEX}].last(0)}>80</p><p>Recovery expression: </p> | information |
Free space is less than 5% on volume {#SNMPVALUE} (LLD) | <p>-</p> | <p>Expression: {SNMP THECUS NAS:raidUsedPercentage[{#SNMPINDEX}].last(0)}>95</p><p>Recovery expression: </p> | high |
Free space is less than 10% on volume {#SNMPVALUE} (LLD) | <p>-</p> | <p>Expression: {SNMP THECUS NAS:raidUsedPercentage[{#SNMPINDEX}].last(0)}>90</p><p>Recovery expression: </p> | warning |
Free space is less than 20% on volume {#SNMPVALUE} (LLD) | <p>-</p> | <p>Expression: {SNMP THECUS NAS:raidUsedPercentage[{#SNMPINDEX}].last(0)}>80</p><p>Recovery expression: </p> | information |
State of {#SNMPVALUE} on {HOST.NAME} is “Current Pending Sector” (LLD) | <p>-</p> | <p>Expression: {SNMP THECUS NAS:diskSMARTAttr197[{#SNMPINDEX}].last(0)}>0</p><p>Recovery expression: </p> | average |
State of {#SNMPVALUE} on {HOST.NAME} is “End-to-End Error” (LLD) | <p>State “noDisk”</p> | <p>Expression: {SNMP THECUS NAS:diskSMARTAttr184[{#SNMPINDEX}].last(0)}>0</p><p>Recovery expression: </p> | average |
State of {#SNMPVALUE} on {HOST.NAME} is “Reallocated_Sector_Ct” (LLD) | <p>State “rwError”</p> | <p>Expression: {SNMP THECUS NAS:diskSMARTAttr5[{#SNMPINDEX}].last(0)}>0</p><p>Recovery expression: </p> | average |
State of {#SNMPVALUE} on {HOST.NAME} is not “Ready” ({ITEM.VALUE1}) (LLD) | <p>-</p> | <p>Expression: {SNMP THECUS NAS:diskStatus[{#SNMPINDEX}].last(0)}=3</p><p>Recovery expression: </p> | high |
Temperature of {#SNMPVALUE} on {HOST.NAME} is over {$HD_TEMPERATURE_ALARM} for 2 min (LLD) | <p>-</p> | <p>Expression: {SNMP THECUS NAS:diskSMARTAttr194[{#SNMPINDEX}].min(2m)}>51</p><p>Recovery expression: </p> | high |
Temperature of {#SNMPVALUE} on {HOST.NAME} is over {$HD_TEMPERATURE_WARNING} for 2min (LLD) | <p>-</p> | <p>Expression: {SNMP THECUS NAS:diskSMARTAttr194[{#SNMPINDEX}].min(2m)}>40</p><p>Recovery expression: </p> | information |
Делал под Thecus N8900
Чтобы нормально получать данные через SNMP ставьте последние прошивки на устройства.
В принципе моя модель - это linux NAS. Через linux SNMPv2 практически все выдается, но в самой
морде есть mib-файл, на его основе и сделал данный шаблон.
Вопросы на 2135850@211.ru
S.V.Sidenko
Name | Description | Default | Type |
---|---|---|---|
{$HD_TEMPERATURE_ALARM} | <p>-</p> | 51 |
Text macro |
{$HD_TEMPERATURE_WARNING} | <p>-</p> | 40 |
Text macro |
{$SNMP_PORT} | <p>-</p> | 161 |
Text macro |
There are no template links in this template.
Name | Description | Type | Key and additional info |
---|---|---|---|
RAID discovery | <p>-</p> | SNMP agent |
nasRaid.discovery<p>Update: 1h</p> |
Hard disks discovery | <p>-</p> | SNMP agent |
nasDisk.discovery<p>Update: 1h</p> |
Name | Description | Type | Key and additional info |
---|---|---|---|
System fan status | <p>-</p> | SNMP agent |
systemFanStatus<p>Update: 60</p> |
System vendor | <p>-</p> | SNMP agent |
systemVendor<p>Update: 3h</p> |
System Mini-UPS Status | <p>-</p> | SNMP agent |
systemMiniUPSStatus<p>Update: 60</p> |
System temperature | <p>System temperature in centigrade</p> | SNMP agent |
systemTemperature<p>Update: 60</p> |
System firmware | <p>-</p> | SNMP agent |
systemFirmware<p>Update: 3h</p> |
System status | <p>-</p> | SNMP agent |
systemStatus<p>Update: 60</p> |
System model | <p>-</p> | SNMP agent |
systemModel<p>Update: 3h</p> |
RAID ID of {#SNMPVALUE} | <p>-</p> | SNMP agent |
raidID[{#SNMPINDEX}]<p>Update: 3h</p><p>LLD</p> |
RAID level of {#SNMPVALUE} | <p>-</p> | SNMP agent |
raidLevel[{#SNMPINDEX}]<p>Update: 3h</p><p>LLD</p> |
RAID number of {#SNMPVALUE} | <p>-</p> | SNMP agent |
raidNum[{#SNMPINDEX}]<p>Update: 3h</p><p>LLD</p> |
RAID size of {#SNMPVALUE} | <p>-</p> | SNMP agent |
raidSize[{#SNMPINDEX}]<p>Update: 1h</p><p>LLD</p> |
RAID status of {#SNMPVALUE} | <p>-</p> | SNMP agent |
raidStatus[{#SNMPINDEX}]<p>Update: 60</p><p>LLD</p> |
RAID units of {#SNMPVALUE} | <p>-</p> | SNMP agent |
raidUnits[{#SNMPINDEX}]<p>Update: 3h</p><p>LLD</p> |
RAID used percent of {#SNMPVALUE} (%) | <p>-</p> | SNMP agent |
raidUsedPercentage[{#SNMPINDEX}]<p>Update: 1h</p><p>LLD</p> |
Disk Capacity {#SNMPVALUE} | <p>-</p> | SNMP agent |
diskCapacity[{#SNMPINDEX}]<p>Update: 1h</p><p>LLD</p> |
Disk ID {#SNMPVALUE} | <p>-</p> | SNMP agent |
diskID[{#SNMPINDEX}]<p>Update: 3h</p><p>LLD</p> |
Model of {#SNMPVALUE} | <p>-</p> | SNMP agent |
diskModel[{#SNMPINDEX}]<p>Update: 3h</p><p>LLD</p> |
Reallocate_Sector_Ct {#SNMPVALUE} | <p>-</p> | SNMP agent |
diskSMARTAttr5[{#SNMPINDEX}]<p>Update: 60</p><p>LLD</p> |
Power_On_hours{#SNMPVALUE} | <p>-</p> | SNMP agent |
diskSMARTAttr9[{#SNMPINDEX}]<p>Update: 60</p><p>LLD</p> |
End-to-End Error {#SNMPVALUE} | <p>-</p> | SNMP agent |
diskSMARTAttr184[{#SNMPINDEX}]<p>Update: 60</p><p>LLD</p> |
Temperature of {#SNMPVALUE} | <p>-</p> | SNMP agent |
diskSMARTAttr194[{#SNMPINDEX}]<p>Update: 60</p><p>LLD</p> |
Current__Pending_Sector {#SNMPVALUE} | <p>-</p> | SNMP agent |
diskSMARTAttr197[{#SNMPINDEX}]<p>Update: 60</p><p>LLD</p> |
S.M.A.R.T. info of {#SNMPVALUE} | <p>-</p> | SNMP agent |
diskSMARTHealthCheck[{#SNMPINDEX}]<p>Update: 60</p><p>LLD</p> |
Status of {#SNMPVALUE} | <p>-</p> | SNMP agent |
diskStatus[{#SNMPINDEX}]<p>Update: 60</p><p>LLD</p> |
Disk Tray Number {#SNMPVALUE} | <p>-</p> | SNMP agent |
diskTrayNum[{#SNMPINDEX}]<p>Update: 3h</p><p>LLD</p> |
Name | Description | Expression | Priority |
---|---|---|---|
State of {#SNMPVALUE} on {HOST.NAME} is “Current Pending Sector” | <p>-</p> | <p>Expression: last(/SNMP THECUS NAS/diskSMARTAttr197[{#SNMPINDEX}])>0</p><p>Recovery expression: </p> | average |
State of {#SNMPVALUE} on {HOST.NAME} is “End-to-End Error” | <p>State “noDisk”</p> | <p>Expression: last(/SNMP THECUS NAS/diskSMARTAttr184[{#SNMPINDEX}])>0</p><p>Recovery expression: </p> | average |
State of {#SNMPVALUE} on {HOST.NAME} is “Reallocated_Sector_Ct” | <p>State “rwError”</p> | <p>Expression: last(/SNMP THECUS NAS/diskSMARTAttr5[{#SNMPINDEX}])>0</p><p>Recovery expression: </p> | average |
State of {#SNMPVALUE} on {HOST.NAME} is not “Ready” ({ITEM.VALUE1}) | <p>-</p> | <p>Expression: last(/SNMP THECUS NAS/diskStatus[{#SNMPINDEX}])=3</p><p>Recovery expression: </p> | high |
Temperature of {#SNMPVALUE} on {HOST.NAME} is over {$HD_TEMPERATURE_ALARM} for 2 min | <p>-</p> | <p>Expression: min(/SNMP THECUS NAS/diskSMARTAttr194[{#SNMPINDEX}],2m)>51</p><p>Recovery expression: </p> | high |
Temperature of {#SNMPVALUE} on {HOST.NAME} is over {$HD_TEMPERATURE_WARNING} for 2min | <p>-</p> | <p>Expression: min(/SNMP THECUS NAS/diskSMARTAttr194[{#SNMPINDEX}],2m)>40</p><p>Recovery expression: </p> | information |
Free space is less than 5% on volume {#SNMPVALUE} | <p>-</p> | <p>Expression: last(/SNMP THECUS NAS/raidUsedPercentage[{#SNMPINDEX}])>95</p><p>Recovery expression: </p> | high |
Free space is less than 10% on volume {#SNMPVALUE} | <p>-</p> | <p>Expression: last(/SNMP THECUS NAS/raidUsedPercentage[{#SNMPINDEX}])>90</p><p>Recovery expression: </p> | warning |
Free space is less than 20% on volume {#SNMPVALUE} | <p>-</p> | <p>Expression: last(/SNMP THECUS NAS/raidUsedPercentage[{#SNMPINDEX}])>80</p><p>Recovery expression: </p> | information |
Free space is less than 5% on volume {#SNMPVALUE} (LLD) | <p>-</p> | <p>Expression: last(/SNMP THECUS NAS/raidUsedPercentage[{#SNMPINDEX}])>95</p><p>Recovery expression: </p> | high |
Free space is less than 10% on volume {#SNMPVALUE} (LLD) | <p>-</p> | <p>Expression: last(/SNMP THECUS NAS/raidUsedPercentage[{#SNMPINDEX}])>90</p><p>Recovery expression: </p> | warning |
Free space is less than 20% on volume {#SNMPVALUE} (LLD) | <p>-</p> | <p>Expression: last(/SNMP THECUS NAS/raidUsedPercentage[{#SNMPINDEX}])>80</p><p>Recovery expression: </p> | information |
State of {#SNMPVALUE} on {HOST.NAME} is “Current Pending Sector” (LLD) | <p>-</p> | <p>Expression: last(/SNMP THECUS NAS/diskSMARTAttr197[{#SNMPINDEX}])>0</p><p>Recovery expression: </p> | average |
State of {#SNMPVALUE} on {HOST.NAME} is “End-to-End Error” (LLD) | <p>State “noDisk”</p> | <p>Expression: last(/SNMP THECUS NAS/diskSMARTAttr184[{#SNMPINDEX}])>0</p><p>Recovery expression: </p> | average |
State of {#SNMPVALUE} on {HOST.NAME} is “Reallocated_Sector_Ct” (LLD) | <p>State “rwError”</p> | <p>Expression: last(/SNMP THECUS NAS/diskSMARTAttr5[{#SNMPINDEX}])>0</p><p>Recovery expression: </p> | average |
State of {#SNMPVALUE} on {HOST.NAME} is not “Ready” ({ITEM.VALUE1}) (LLD) | <p>-</p> | <p>Expression: last(/SNMP THECUS NAS/diskStatus[{#SNMPINDEX}])=3</p><p>Recovery expression: </p> | high |
Temperature of {#SNMPVALUE} on {HOST.NAME} is over {$HD_TEMPERATURE_ALARM} for 2 min (LLD) | <p>-</p> | <p>Expression: min(/SNMP THECUS NAS/diskSMARTAttr194[{#SNMPINDEX}],2m)>51</p><p>Recovery expression: </p> | high |
Temperature of {#SNMPVALUE} on {HOST.NAME} is over {$HD_TEMPERATURE_WARNING} for 2min (LLD) | <p>-</p> | <p>Expression: min(/SNMP THECUS NAS/diskSMARTAttr194[{#SNMPINDEX}],2m)>40</p><p>Recovery expression: </p> | information |
Делал под Thecus N8900
Чтобы нормально получать данные через SNMP ставьте последние прошивки на устройства.
В принципе моя модель - это linux NAS. Через linux SNMPv2 практически все выдается, но в самой
морде есть mib-файл, на его основе и сделал данный шаблон.
Вопросы на 2135850@211.ru
S.V.Sidenko
Name | Description | Default | Type |
---|---|---|---|
{$HD_TEMPERATURE_ALARM} | <p>-</p> | 51 |
Text macro |
{$HD_TEMPERATURE_WARNING} | <p>-</p> | 40 |
Text macro |
{$SNMP_PORT} | <p>-</p> | 161 |
Text macro |
There are no template links in this template.
Name | Description | Type | Key and additional info |
---|---|---|---|
RAID discovery | <p>-</p> | SNMP agent |
nasRaid.discovery<p>Update: 1h</p> |
Hard disks discovery | <p>-</p> | SNMP agent |
nasDisk.discovery<p>Update: 1h</p> |
Name | Description | Type | Key and additional info |
---|---|---|---|
System fan status | <p>-</p> | SNMP agent |
systemFanStatus<p>Update: 60</p> |
System vendor | <p>-</p> | SNMP agent |
systemVendor<p>Update: 3h</p> |
System Mini-UPS Status | <p>-</p> | SNMP agent |
systemMiniUPSStatus<p>Update: 60</p> |
System temperature | <p>System temperature in centigrade</p> | SNMP agent |
systemTemperature<p>Update: 60</p> |
System firmware | <p>-</p> | SNMP agent |
systemFirmware<p>Update: 3h</p> |
System status | <p>-</p> | SNMP agent |
systemStatus<p>Update: 60</p> |
System model | <p>-</p> | SNMP agent |
systemModel<p>Update: 3h</p> |
RAID ID of {#SNMPVALUE} | <p>-</p> | SNMP agent |
raidID[{#SNMPINDEX}]<p>Update: 3h</p><p>LLD</p> |
RAID level of {#SNMPVALUE} | <p>-</p> | SNMP agent |
raidLevel[{#SNMPINDEX}]<p>Update: 3h</p><p>LLD</p> |
RAID number of {#SNMPVALUE} | <p>-</p> | SNMP agent |
raidNum[{#SNMPINDEX}]<p>Update: 3h</p><p>LLD</p> |
RAID size of {#SNMPVALUE} | <p>-</p> | SNMP agent |
raidSize[{#SNMPINDEX}]<p>Update: 1h</p><p>LLD</p> |
RAID status of {#SNMPVALUE} | <p>-</p> | SNMP agent |
raidStatus[{#SNMPINDEX}]<p>Update: 60</p><p>LLD</p> |
RAID units of {#SNMPVALUE} | <p>-</p> | SNMP agent |
raidUnits[{#SNMPINDEX}]<p>Update: 3h</p><p>LLD</p> |
RAID used percent of {#SNMPVALUE} (%) | <p>-</p> | SNMP agent |
raidUsedPercentage[{#SNMPINDEX}]<p>Update: 1h</p><p>LLD</p> |
Disk Capacity {#SNMPVALUE} | <p>-</p> | SNMP agent |
diskCapacity[{#SNMPINDEX}]<p>Update: 1h</p><p>LLD</p> |
Disk ID {#SNMPVALUE} | <p>-</p> | SNMP agent |
diskID[{#SNMPINDEX}]<p>Update: 3h</p><p>LLD</p> |
Model of {#SNMPVALUE} | <p>-</p> | SNMP agent |
diskModel[{#SNMPINDEX}]<p>Update: 3h</p><p>LLD</p> |
Reallocate_Sector_Ct {#SNMPVALUE} | <p>-</p> | SNMP agent |
diskSMARTAttr5[{#SNMPINDEX}]<p>Update: 60</p><p>LLD</p> |
Power_On_hours{#SNMPVALUE} | <p>-</p> | SNMP agent |
diskSMARTAttr9[{#SNMPINDEX}]<p>Update: 60</p><p>LLD</p> |
End-to-End Error {#SNMPVALUE} | <p>-</p> | SNMP agent |
diskSMARTAttr184[{#SNMPINDEX}]<p>Update: 60</p><p>LLD</p> |
Temperature of {#SNMPVALUE} | <p>-</p> | SNMP agent |
diskSMARTAttr194[{#SNMPINDEX}]<p>Update: 60</p><p>LLD</p> |
Current__Pending_Sector {#SNMPVALUE} | <p>-</p> | SNMP agent |
diskSMARTAttr197[{#SNMPINDEX}]<p>Update: 60</p><p>LLD</p> |
S.M.A.R.T. info of {#SNMPVALUE} | <p>-</p> | SNMP agent |
diskSMARTHealthCheck[{#SNMPINDEX}]<p>Update: 60</p><p>LLD</p> |
Status of {#SNMPVALUE} | <p>-</p> | SNMP agent |
diskStatus[{#SNMPINDEX}]<p>Update: 60</p><p>LLD</p> |
Disk Tray Number {#SNMPVALUE} | <p>-</p> | SNMP agent |
diskTrayNum[{#SNMPINDEX}]<p>Update: 3h</p><p>LLD</p> |
Name | Description | Expression | Priority |
---|---|---|---|
State of {#SNMPVALUE} on {HOST.NAME} is “Current Pending Sector” | <p>-</p> | <p>Expression: last(/SNMP THECUS NAS/diskSMARTAttr197[{#SNMPINDEX}])>0</p><p>Recovery expression: </p> | average |
State of {#SNMPVALUE} on {HOST.NAME} is “End-to-End Error” | <p>State “noDisk”</p> | <p>Expression: last(/SNMP THECUS NAS/diskSMARTAttr184[{#SNMPINDEX}])>0</p><p>Recovery expression: </p> | average |
State of {#SNMPVALUE} on {HOST.NAME} is “Reallocated_Sector_Ct” | <p>State “rwError”</p> | <p>Expression: last(/SNMP THECUS NAS/diskSMARTAttr5[{#SNMPINDEX}])>0</p><p>Recovery expression: </p> | average |
State of {#SNMPVALUE} on {HOST.NAME} is not “Ready” ({ITEM.VALUE1}) | <p>-</p> | <p>Expression: last(/SNMP THECUS NAS/diskStatus[{#SNMPINDEX}])=3</p><p>Recovery expression: </p> | high |
Temperature of {#SNMPVALUE} on {HOST.NAME} is over {$HD_TEMPERATURE_ALARM} for 2 min | <p>-</p> | <p>Expression: min(/SNMP THECUS NAS/diskSMARTAttr194[{#SNMPINDEX}],2m)>51</p><p>Recovery expression: </p> | high |
Temperature of {#SNMPVALUE} on {HOST.NAME} is over {$HD_TEMPERATURE_WARNING} for 2min | <p>-</p> | <p>Expression: min(/SNMP THECUS NAS/diskSMARTAttr194[{#SNMPINDEX}],2m)>40</p><p>Recovery expression: </p> | information |
Free space is less than 5% on volume {#SNMPVALUE} | <p>-</p> | <p>Expression: last(/SNMP THECUS NAS/raidUsedPercentage[{#SNMPINDEX}])>95</p><p>Recovery expression: </p> | high |
Free space is less than 10% on volume {#SNMPVALUE} | <p>-</p> | <p>Expression: last(/SNMP THECUS NAS/raidUsedPercentage[{#SNMPINDEX}])>90</p><p>Recovery expression: </p> | warning |
Free space is less than 20% on volume {#SNMPVALUE} | <p>-</p> | <p>Expression: last(/SNMP THECUS NAS/raidUsedPercentage[{#SNMPINDEX}])>80</p><p>Recovery expression: </p> | information |
Free space is less than 5% on volume {#SNMPVALUE} (LLD) | <p>-</p> | <p>Expression: last(/SNMP THECUS NAS/raidUsedPercentage[{#SNMPINDEX}])>95</p><p>Recovery expression: </p> | high |
Free space is less than 10% on volume {#SNMPVALUE} (LLD) | <p>-</p> | <p>Expression: last(/SNMP THECUS NAS/raidUsedPercentage[{#SNMPINDEX}])>90</p><p>Recovery expression: </p> | warning |
Free space is less than 20% on volume {#SNMPVALUE} (LLD) | <p>-</p> | <p>Expression: last(/SNMP THECUS NAS/raidUsedPercentage[{#SNMPINDEX}])>80</p><p>Recovery expression: </p> | information |
State of {#SNMPVALUE} on {HOST.NAME} is “Current Pending Sector” (LLD) | <p>-</p> | <p>Expression: last(/SNMP THECUS NAS/diskSMARTAttr197[{#SNMPINDEX}])>0</p><p>Recovery expression: </p> | average |
State of {#SNMPVALUE} on {HOST.NAME} is “End-to-End Error” (LLD) | <p>State “noDisk”</p> | <p>Expression: last(/SNMP THECUS NAS/diskSMARTAttr184[{#SNMPINDEX}])>0</p><p>Recovery expression: </p> | average |
State of {#SNMPVALUE} on {HOST.NAME} is “Reallocated_Sector_Ct” (LLD) | <p>State “rwError”</p> | <p>Expression: last(/SNMP THECUS NAS/diskSMARTAttr5[{#SNMPINDEX}])>0</p><p>Recovery expression: </p> | average |
State of {#SNMPVALUE} on {HOST.NAME} is not “Ready” ({ITEM.VALUE1}) (LLD) | <p>-</p> | <p>Expression: last(/SNMP THECUS NAS/diskStatus[{#SNMPINDEX}])=3</p><p>Recovery expression: </p> | high |
Temperature of {#SNMPVALUE} on {HOST.NAME} is over {$HD_TEMPERATURE_ALARM} for 2 min (LLD) | <p>-</p> | <p>Expression: min(/SNMP THECUS NAS/diskSMARTAttr194[{#SNMPINDEX}],2m)>51</p><p>Recovery expression: </p> | high |
Temperature of {#SNMPVALUE} on {HOST.NAME} is over {$HD_TEMPERATURE_WARNING} for 2min (LLD) | <p>-</p> | <p>Expression: min(/SNMP THECUS NAS/diskSMARTAttr194[{#SNMPINDEX}],2m)>40</p><p>Recovery expression: </p> | information |