README: https://github.com/hacktivism-github/zbx-templates-repository/blob/master/zbx-infinera/README.md
Bruno Teixeira
There are no macros links in this template.
There are no template links in this template.
Name | Description | Type | Key and additional info |
---|---|---|---|
XTM Series::Equipment Status::Power Supply Status | <p>-</p> | SNMP agent |
equipmentPowerName<p>Update: 300</p> |
XTM Series::PM EthTD::Current Meters and Configuration | <p>-</p> | SNMP agent |
pmEthTdName<p>Update: 300</p> |
XTM Series::Equipment Status::Fan status | <p>-</p> | SNMP agent |
equipmentFanName<p>Update: 300</p> |
XTM Series::PM Rx/Tx Power Levels::Current Meters and Configuration | <p>-</p> | SNMP agent |
pmIfName<p>Update: 300</p> |
XTM Series::Equipment Status::Board Configuration and Status | <p>-</p> | SNMP agent |
equipmentBoardName<p>Update: 300</p> |
XTM Series::Equipment Status::Subrack Status | <p>-</p> | SNMP agent |
equipmentSubrackName<p>Update: 300</p> |
XTM Series::Client Interfaces::EMXPxxx | <p>-</p> | SNMP agent |
clientIfName<p>Update: 300</p> |
XTM Series::Optical Amplifiers | <p>-</p> | SNMP agent |
oaIfName<p>Update: 300</p> |
XTM Series::DCN::CU SFP/II::Optical Supervisory Channel | <p>-</p> | SNMP agent |
dcnIfName<p>Update: 300</p> |
XTM Series::Metro Ethernet Services | <p>-</p> | SNMP agent |
mesErrorPropName<p>Update: 30</p> |
Name | Description | Type | Key and additional info | ||
---|---|---|---|---|---|
XTM Series | Unsaved Changes Alarm | <p>-</p> | SNMP agent |
backupGeneralUnsavedChangesAlarm<p>Update: 300</p> | |
XTM Series | equipmentPowerDCPowerFailedSeverity $1 | <p>-</p> | SNMP agent |
equipmentPowerDCPowerFailedSeverity[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | equipmentPowerDCPowerFailed $1 | <p>-</p> | SNMP agent |
equipmentPowerDCPowerFailed[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | equipmentPowerName $1 | <p>-</p> | SNMP agent |
equipmentPowerName[{#SNMPVALUE}]<p>Update: 86400</p><p>LLD</p> | |
XTM Series | equipmentPowerOperStatus $1 | <p>-</p> | SNMP agent |
equipmentPowerOperStatus[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | equipmentPowerType $1 | <p>-</p> | SNMP agent |
equipmentPowerType[{#SNMPVALUE}]<p>Update: 86400</p><p>LLD</p> | |
XTM Series | Rx Ethernet Traffic Data on $1 | <p>-</p> | SNMP agent |
pmEthTdCurrentContRxOctets[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | Tx Ethernet Traffic Data on $1 | <p>-</p> | SNMP agent |
pmEthTdCurrentContTxOctets[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | pmEthTdName $1 | <p>-</p> | SNMP agent |
pmEthTdName[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | equipmentFanName $1 | <p>-</p> | SNMP agent |
equipmentFanName[{#SNMPVALUE}]<p>Update: 86400</p><p>LLD</p> | |
XTM Series | equipmentFanOperStatus $1 | <p>-</p> | SNMP agent |
equipmentFanOperStatus[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | equipmentFanUnitFailed $1 | <p>-</p> | SNMP agent |
equipmentFanUnitFailed[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | pmIfAdminStatus $1 | <p>-</p> | SNMP agent |
pmIfAdminStatus[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | pmIfName $1 | <p>-</p> | SNMP agent |
pmIfName[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | pmIfOperStatus $1 | <p>-</p> | SNMP agent |
pmIfOperStatus[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | pmIfRx24hCurrentUAS on $1 | <p>-</p> | SNMP agent |
pmIfRx24hCurrentUAS[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | pmIfRx24hUASThreshold on $1 | <p>-</p> | SNMP agent |
pmIfRx24hUASThreshold[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | pmIfRx24hUAS on $1 | <p>-</p> | SNMP agent |
pmIfRx24hUAS[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | Rx Power Level on $1 | <p>-</p> | SNMP agent |
pmIfRxPowerLevel[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | pmIfTx24hCurrentUAS on $1 | <p>-</p> | SNMP agent |
pmIfTx24hCurrentUAS[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | pmIfTx24hUASThreshold on $1 | <p>-</p> | SNMP agent |
pmIfTx24hUASThreshold[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | pmIfTx24hUAS on $1 | <p>-</p> | SNMP agent |
pmIfTx24hUAS[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | Tx Power Level on $1 | <p>-</p> | SNMP agent |
pmIfTxPowerLevel[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | CU-SFP/II | Communication Failure on $1 | <p>-</p> | SNMP agent |
equipmentBoardCommunicationFailure[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> |
XTM Series | equipmentBoardName $1 | <p>-</p> | SNMP agent |
equipmentBoardName[{#SNMPVALUE}]<p>Update: 86400</p><p>LLD</p> | |
XTM Series | equipmentBoardOperStatus $1 | <p>-</p> | SNMP agent |
equipmentBoardOperStatus[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | Secondary DC Power Failed on $1 | <p>-</p> | SNMP agent |
equipmentBoardSecondaryPowerFailed[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | High Board Temperature on $1 | <p>-</p> | SNMP agent |
equipmentBoardTempHighExceeded[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | Equipment Board Temp Low Threshold on $1 | <p>-</p> | SNMP agent |
equipmentBoardTempLowThreshold[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | Equipment Board Temp Low on $1 | <p>-</p> | SNMP agent |
equipmentBoardTempLow[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | Equipment Board Temp Threshold on $1 | <p>-</p> | SNMP agent |
equipmentBoardTempThreshold[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | Equipment Board Temp Very High on $1 | <p>-</p> | SNMP agent |
equipmentBoardTempVeryHigh[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | equipmentBoardUnderMaintenance $1 | <p>-</p> | SNMP agent |
equipmentBoardUnderMaintenance[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | equipmentSubrackName $1 | <p>-</p> | SNMP agent |
equipmentSubrackName[{#SNMPVALUE}]<p>Update: 86400</p><p>LLD</p> | |
XTM Series | equipmentSubrackOperStatus on $1 | <p>-</p> | SNMP agent |
equipmentSubrackOperStatus[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | equipmentSubrackTempHighExceeded on $1 | <p>-</p> | SNMP agent |
equipmentSubrackTempHighExceeded[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | Equipment Subrack Temperature Threshold on $1 | <p>-</p> | SNMP agent |
equipmentSubrackTempThreshold[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | Equipment Subrack Temperature on $1 | <p>-</p> | SNMP agent |
equipmentSubrackTemp[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | clientIfAdminStatus $1 | <p>-</p> | SNMP agent |
clientIfAdminStatus[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | Description on interface $1 | <p>-</p> | SNMP agent |
clientIfDescr[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
TM-3000/II Chassis | clientIfLossOfSignal $1 | <p>-</p> | SNMP agent |
clientIfLossOfSignal[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
TM-3000/II Chassis | clientIfName $1 | <p>-</p> | SNMP agent |
clientIfName[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | clientIfOperStatus $1 | <p>-</p> | SNMP agent |
clientIfOperStatus[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | clientIfPowerLevelLowRelativeThreshold $1 | <p>-</p> | SNMP agent |
clientIfPowerLevelLowRelativeThreshold[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | clientIfPowerLevel $1 | <p>-</p> | SNMP agent |
clientIfPowerLevel[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
TM-3000/II Chassis | clientIfReceivedPowerHigh $1 | <p>-</p> | SNMP agent |
clientIfReceivedPowerHigh[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
TM-3000/II Chassis | clientIfReceivedPowerLow on $1 | <p>-</p> | SNMP agent |
clientIfReceivedPowerLow[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | clientIfReceiverSensitivity $1 | <p>LUM-CLIENT-MIB::clientIfReceiverSensitivity The lowest power that the receiver is guaranteed to handle, in units of 0.1 dBm.</p> | SNMP agent |
clientIfReceiverSensitivity[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | clientIfRxSignalStatus $1 | <p>-</p> | SNMP agent |
clientIfRxSignalStatus[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | OA Adminintrative State for the interface $1 | <p>-</p> | SNMP agent |
oaIfAdminStatus[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | OA interface Description for $1 | <p>-</p> | SNMP agent |
oaIfDescr[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | OA Laser Bias High on $1 | <p>-</p> | SNMP agent |
oaIfLaserBiasHigh[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | OA Loss Of Signal on $1 | <p>-</p> | SNMP agent |
oaIfLossOfSignal[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | OA interface $1 | <p>-</p> | SNMP agent |
oaIfName.me[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | OA Operational State for the interface $1 | <p>-</p> | SNMP agent |
oaIfOperStatus[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | OA Output Power Fail on $1 | <p>-</p> | SNMP agent |
oaIfOutputPowerFail[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | OA Pump Laser Temp Low on $1 | <p>-</p> | SNMP agent |
oaIfPumpLaserTempLow[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | OA Received Power Low on $1 | <p>-</p> | SNMP agent |
oaIfReceivedPowerLow[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | OA Rx Power Level Low Threshold on $1 | <p>-</p> | SNMP agent |
oaIfRxPowerLevelLowThreshold[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | OA Rx power level on $1 | <p>-</p> | SNMP agent |
oaIfRxPowerLevel[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | OA Saturation Fault on $1 | <p>-</p> | SNMP agent |
oaIfSaturationFault[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | OA Tx Power Level Low Threshold on $1 | <p>-</p> | SNMP agent |
oaIfTxPowerLevelLowThreshold[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | OA Tx power level on $1 | <p>-</p> | SNMP agent |
oaIfTxPowerLevel[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
TM-3000/II Chassis | CU SFP/II | dcnIfDescr $1 | <p>-</p> | SNMP agent |
dcnIfDescr[{#SNMPVALUE}]<p>Update: 3600</p><p>LLD</p> |
TM-3000/II Chassis | CU SFP/II | dcnIfName $1 | <p>-</p> | SNMP agent |
dcnIfName[{#SNMPVALUE}]<p>Update: 3600</p><p>LLD</p> |
TM-3000/II Chassis | CU SFP/II | dcnIfOperStatus $1 | <p>-</p> | SNMP agent |
dcnIfOperStatus[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> |
TM-3000/II Chassis | CU SFP/II | dcnIfPowerLevel $1 | <p>-</p> | SNMP agent |
dcnIfPowerLevel[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> |
TM-3000/II Chassis | CU SFP/II | dcnIfReceivedPowerHigh $1 | <p>-</p> | SNMP agent |
dcnIfReceivedPowerHigh[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> |
TM-3000/II Chassis | CU SFP/II | dcnIfReceivedPowerLow $1 | <p>-</p> | SNMP agent |
dcnIfReceivedPowerLow[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> |
XTM Series | MES Error Propagation Fault on $1 | <p>-</p> | SNMP agent |
mesErrorPropFault[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> |
Name | Description | Expression | Priority | |
---|---|---|---|---|
[10.002] EMXP240/IIE | Low Rx Optical Power on {#SNMPVALUE} : {ITEM.VALUE2} | <p>-</p> | <p>Expression: {ZBX-INFINERA-XTM-SERIES-MONITORING:clientIfReceivedPowerLow[{#SNMPVALUE}].last(#1)}<>1 and {ZBX-INFINERA-XTM-SERIES-MONITORING:clientIfDescr[{#SNMPVALUE}].str(this_does_not_exist)}=0</p><p>Recovery expression: </p> | warning |
[10.002] High Rx Optical Power on {#SNMPVALUE} | <p>-</p> | <p>Expression: {ZBX-INFINERA-XTM-SERIES-MONITORING:clientIfPowerLevel[{#SNMPVALUE}].last(#1)}>=-10</p><p>Recovery expression: </p> | high | |
[10.002] Low Rx Optical Power on {#SNMPVALUE} | <p>-</p> | <p>Expression: {ZBX-INFINERA-XTM-SERIES-MONITORING:clientIfPowerLevel[{#SNMPVALUE}].last(#1)}<=-9</p><p>Recovery expression: </p> | warning | |
[10.003] EMXP240/IIE | Loss of Signal on {#SNMPVALUE} : {ITEM.VALUE2} | <p>-</p> | <p>Expression: {ZBX-INFINERA-XTM-SERIES-MONITORING:clientIfLossOfSignal[{#SNMPVALUE}].last(#1)}<>1 and {ZBX-INFINERA-XTM-SERIES-MONITORING:clientIfDescr[{#SNMPVALUE}].str(this_does_not_exist)}=0</p><p>Recovery expression: </p> | high |
[10.002] CU SFP/II | High Rx Optical Power on {#SNMPVALUE} : {ITEM.VALUE2} | <p>-</p> | <p>Expression: {ZBX-INFINERA-XTM-SERIES-MONITORING:dcnIfReceivedPowerHigh[{#SNMPVALUE}].last(#1)}<>1 and {ZBX-INFINERA-XTM-SERIES-MONITORING:dcnIfDescr[{#SNMPVALUE}].str(this_does_not_exist)}=0</p><p>Recovery expression: </p> | high |
[10.002] CU SFP/II | Low Rx Optical Power on {#SNMPVALUE} : {ITEM.VALUE2} | <p>-</p> | <p>Expression: {ZBX-INFINERA-XTM-SERIES-MONITORING:dcnIfReceivedPowerLow[{#SNMPVALUE}].last(#1)}<>1 and {ZBX-INFINERA-XTM-SERIES-MONITORING:dcnIfDescr[{#SNMPVALUE}].str(this_does_not_exist)}=0</p><p>Recovery expression: </p> | warning |
[10.004] Board Under Maintenance {#SNMPVALUE} | <p>-</p> | <p>Expression: {ZBX-INFINERA-XTM-SERIES-MONITORING:equipmentBoardUnderMaintenance[{#SNMPVALUE}].last(#1)}<>1</p><p>Recovery expression: </p> | information | |
[] CU SFP/II Communication Failure with {#SNMPVALUE} | <p>-</p> | <p>Expression: {ZBX-INFINERA-XTM-SERIES-MONITORING:equipmentBoardCommunicationFailure[{#SNMPVALUE}].last(#1)}<>1</p><p>Recovery expression: </p> | high | |
[] Equipment Board Temperature Very High on {#SNMPVALUE} | <p>-</p> | <p>Expression: {ZBX-INFINERA-XTM-SERIES-MONITORING:equipmentBoardTempVeryHigh[{#SNMPVALUE}].last(#1)}<>1</p><p>Recovery expression: </p> | warning | |
[] High Board Temperature on {#SNMPVALUE} | <p>-</p> | <p>Expression: {ZBX-INFINERA-XTM-SERIES-MONITORING:equipmentBoardTempHighExceeded[{#SNMPVALUE}].last(#1)}<>1</p><p>Recovery expression: </p> | high | |
[] Secondary DC Power Failed on {#SNMPVALUE} | <p>-</p> | <p>Expression: {ZBX-INFINERA-XTM-SERIES-MONITORING:equipmentBoardSecondaryPowerFailed[{#SNMPVALUE}].last(#1)}<>1</p><p>Recovery expression: </p> | high | |
[02.009] {#SNMPVALUE} Fan Unit Failed | <p>-</p> | <p>Expression: {ZBX-INFINERA-XTM-SERIES-MONITORING:equipmentFanUnitFailed[{#SNMPVALUE}].last(#1)}<>1</p><p>Recovery expression: </p> | warning | |
[04.104] {#SNMPVALUE} DC Power Supply Failed | <p>-</p> | <p>Expression: {ZBX-INFINERA-XTM-SERIES-MONITORING:equipmentPowerDCPowerFailed[{#SNMPVALUE}].last(#1)}<>1</p><p>Recovery expression: </p> | high | |
[02.010] High Subrack Temperature $1 | <p>-</p> | <p>Expression: {ZBX-INFINERA-XTM-SERIES-MONITORING:equipmentSubrackTempHighExceeded[{#SNMPVALUE}].last(#1)}<>1</p><p>Recovery expression: </p> | warning | |
[10.005] EMXP240/IIE | Error Propagation Active on {#SNMPVALUE} | <p>-</p> | <p>Expression: {ZBX-INFINERA-XTM-SERIES-MONITORING:mesErrorPropFault[{#SNMPVALUE}].last(#1)}<>1</p><p>Recovery expression: </p> | warning |
[10.003] OA2 LG 20/20C | Loss of Signal on interface {#SNMPVALUE} : {ITEM.VALUE2} | <p>-</p> | <p>Expression: {ZBX-INFINERA-XTM-SERIES-MONITORING:oaIfLossOfSignal[{#SNMPVALUE}].last(#1)}<>1 and {ZBX-INFINERA-XTM-SERIES-MONITORING:oaIfDescr[{#SNMPVALUE}].str(this_does_not_exist)}=0</p><p>Recovery expression: </p> | high |
[10.006] OA Low Received Optical Power on {#SNMPVALUE} | <p>-</p> | <p>Expression: {ZBX-INFINERA-XTM-SERIES-MONITORING:oaIfReceivedPowerLow[{#SNMPVALUE}].last(#1)}<>1</p><p>Recovery expression: </p> | warning | |
[] OA Amplifier Saturation alarm on {#SNMPVALUE} | <p>-</p> | <p>Expression: {ZBX-INFINERA-XTM-SERIES-MONITORING:oaIfSaturationFault[{#SNMPVALUE}].last(#1)}<>1</p><p>Recovery expression: </p> | information | |
[] OA High Laser Bias on {#SNMPVALUE} | <p>-</p> | <p>Expression: {ZBX-INFINERA-XTM-SERIES-MONITORING:oaIfLaserBiasHigh[{#SNMPVALUE}].last(#1)}<>1</p><p>Recovery expression: </p> | information | |
[] OA interface {#SNMPVALUE} changed its Operational state to DOWN | <p>-</p> | <p>Expression: {ZBX-INFINERA-XTM-SERIES-MONITORING:oaIfOperStatus[{#SNMPVALUE}].last(#1)}<>3</p><p>Recovery expression: </p> | high | |
[] OA Output power failed on {#SNMPVALUE} | <p>-</p> | <p>Expression: {ZBX-INFINERA-XTM-SERIES-MONITORING:oaIfOutputPowerFail[{#SNMPVALUE}].last(#1)}<>1</p><p>Recovery expression: </p> | high | |
[] OA Pump Laser Temp Low on {#SNMPVALUE} | <p>-</p> | <p>Expression: {ZBX-INFINERA-XTM-SERIES-MONITORING:oaIfPumpLaserTempLow[{#SNMPVALUE}].last(#1)}<>1</p><p>Recovery expression: </p> | warning | |
UAS Rx 24 hour Threshold Exceeded on {#SNMPVALUE} | <p>-</p> | <p>Expression: {ZBX-INFINERA-XTM-SERIES-MONITORING:pmIfRx24hCurrentUAS[{#SNMPVALUE}].last(#1)}>300</p><p>Recovery expression: </p> | warning | |
UAS Tx 24 hour Threshold Exceeded on {#SNMPVALUE} | <p>-</p> | <p>Expression: {ZBX-INFINERA-XTM-SERIES-MONITORING:pmIfAdminStatus[{#SNMPVALUE}].last(#1)}=2 or {ZBX-INFINERA-XTM-SERIES-MONITORING:pmIfAdminStatus[{#SNMPVALUE}].last(#1)}=3 and {ZBX-INFINERA-XTM-SERIES-MONITORING:pmIfTx24hCurrentUAS[{#SNMPVALUE}].last(#1)}>300</p><p>Recovery expression: </p> | warning | |
[04.104] {#SNMPVALUE} DC Power Supply Failed (LLD) | <p>-</p> | <p>Expression: {ZBX-INFINERA-XTM-SERIES-MONITORING:equipmentPowerDCPowerFailed[{#SNMPVALUE}].last(#1)}<>1</p><p>Recovery expression: </p> | high | |
[02.009] {#SNMPVALUE} Fan Unit Failed (LLD) | <p>-</p> | <p>Expression: {ZBX-INFINERA-XTM-SERIES-MONITORING:equipmentFanUnitFailed[{#SNMPVALUE}].last(#1)}<>1</p><p>Recovery expression: </p> | warning | |
UAS Rx 24 hour Threshold Exceeded on {#SNMPVALUE} (LLD) | <p>-</p> | <p>Expression: {ZBX-INFINERA-XTM-SERIES-MONITORING:pmIfRx24hCurrentUAS[{#SNMPVALUE}].last(#1)}>300</p><p>Recovery expression: </p> | warning | |
UAS Tx 24 hour Threshold Exceeded on {#SNMPVALUE} (LLD) | <p>-</p> | <p>Expression: {ZBX-INFINERA-XTM-SERIES-MONITORING:pmIfAdminStatus[{#SNMPVALUE}].last(#1)}=2 or {ZBX-INFINERA-XTM-SERIES-MONITORING:pmIfAdminStatus[{#SNMPVALUE}].last(#1)}=3 and {ZBX-INFINERA-XTM-SERIES-MONITORING:pmIfTx24hCurrentUAS[{#SNMPVALUE}].last(#1)}>300</p><p>Recovery expression: </p> | warning | |
[10.004] Board Under Maintenance {#SNMPVALUE} (LLD) | <p>-</p> | <p>Expression: {ZBX-INFINERA-XTM-SERIES-MONITORING:equipmentBoardUnderMaintenance[{#SNMPVALUE}].last(#1)}<>1</p><p>Recovery expression: </p> | information | |
[] CU SFP/II Communication Failure with {#SNMPVALUE} (LLD) | <p>-</p> | <p>Expression: {ZBX-INFINERA-XTM-SERIES-MONITORING:equipmentBoardCommunicationFailure[{#SNMPVALUE}].last(#1)}<>1</p><p>Recovery expression: </p> | high | |
[] Equipment Board Temperature Very High on {#SNMPVALUE} (LLD) | <p>-</p> | <p>Expression: {ZBX-INFINERA-XTM-SERIES-MONITORING:equipmentBoardTempVeryHigh[{#SNMPVALUE}].last(#1)}<>1</p><p>Recovery expression: </p> | warning | |
[] High Board Temperature on {#SNMPVALUE} (LLD) | <p>-</p> | <p>Expression: {ZBX-INFINERA-XTM-SERIES-MONITORING:equipmentBoardTempHighExceeded[{#SNMPVALUE}].last(#1)}<>1</p><p>Recovery expression: </p> | high | |
[] Secondary DC Power Failed on {#SNMPVALUE} (LLD) | <p>-</p> | <p>Expression: {ZBX-INFINERA-XTM-SERIES-MONITORING:equipmentBoardSecondaryPowerFailed[{#SNMPVALUE}].last(#1)}<>1</p><p>Recovery expression: </p> | high | |
[02.010] High Subrack Temperature $1 (LLD) | <p>-</p> | <p>Expression: {ZBX-INFINERA-XTM-SERIES-MONITORING:equipmentSubrackTempHighExceeded[{#SNMPVALUE}].last(#1)}<>1</p><p>Recovery expression: </p> | warning | |
[10.002] EMXP240/IIE | Low Rx Optical Power on {#SNMPVALUE} : {ITEM.VALUE2} (LLD) | <p>-</p> | <p>Expression: {ZBX-INFINERA-XTM-SERIES-MONITORING:clientIfReceivedPowerLow[{#SNMPVALUE}].last(#1)}<>1 and {ZBX-INFINERA-XTM-SERIES-MONITORING:clientIfDescr[{#SNMPVALUE}].str(this_does_not_exist)}=0</p><p>Recovery expression: </p> | warning |
[10.002] High Rx Optical Power on {#SNMPVALUE} (LLD) | <p>-</p> | <p>Expression: {ZBX-INFINERA-XTM-SERIES-MONITORING:clientIfPowerLevel[{#SNMPVALUE}].last(#1)}>=-10</p><p>Recovery expression: </p> | high | |
[10.002] Low Rx Optical Power on {#SNMPVALUE} (LLD) | <p>-</p> | <p>Expression: {ZBX-INFINERA-XTM-SERIES-MONITORING:clientIfPowerLevel[{#SNMPVALUE}].last(#1)}<=-9</p><p>Recovery expression: </p> | warning | |
[10.003] EMXP240/IIE | Loss of Signal on {#SNMPVALUE} : {ITEM.VALUE2} (LLD) | <p>-</p> | <p>Expression: {ZBX-INFINERA-XTM-SERIES-MONITORING:clientIfLossOfSignal[{#SNMPVALUE}].last(#1)}<>1 and {ZBX-INFINERA-XTM-SERIES-MONITORING:clientIfDescr[{#SNMPVALUE}].str(this_does_not_exist)}=0</p><p>Recovery expression: </p> | high |
[10.003] OA2 LG 20/20C | Loss of Signal on interface {#SNMPVALUE} : {ITEM.VALUE2} (LLD) | <p>-</p> | <p>Expression: {ZBX-INFINERA-XTM-SERIES-MONITORING:oaIfLossOfSignal[{#SNMPVALUE}].last(#1)}<>1 and {ZBX-INFINERA-XTM-SERIES-MONITORING:oaIfDescr[{#SNMPVALUE}].str(this_does_not_exist)}=0</p><p>Recovery expression: </p> | high |
[10.006] OA Low Received Optical Power on {#SNMPVALUE} (LLD) | <p>-</p> | <p>Expression: {ZBX-INFINERA-XTM-SERIES-MONITORING:oaIfReceivedPowerLow[{#SNMPVALUE}].last(#1)}<>1</p><p>Recovery expression: </p> | warning | |
[] OA Amplifier Saturation alarm on {#SNMPVALUE} (LLD) | <p>-</p> | <p>Expression: {ZBX-INFINERA-XTM-SERIES-MONITORING:oaIfSaturationFault[{#SNMPVALUE}].last(#1)}<>1</p><p>Recovery expression: </p> | information | |
[] OA High Laser Bias on {#SNMPVALUE} (LLD) | <p>-</p> | <p>Expression: {ZBX-INFINERA-XTM-SERIES-MONITORING:oaIfLaserBiasHigh[{#SNMPVALUE}].last(#1)}<>1</p><p>Recovery expression: </p> | information | |
[] OA interface {#SNMPVALUE} changed its Operational state to DOWN (LLD) | <p>-</p> | <p>Expression: {ZBX-INFINERA-XTM-SERIES-MONITORING:oaIfOperStatus[{#SNMPVALUE}].last(#1)}<>3</p><p>Recovery expression: </p> | high | |
[] OA Output power failed on {#SNMPVALUE} (LLD) | <p>-</p> | <p>Expression: {ZBX-INFINERA-XTM-SERIES-MONITORING:oaIfOutputPowerFail[{#SNMPVALUE}].last(#1)}<>1</p><p>Recovery expression: </p> | high | |
[] OA Pump Laser Temp Low on {#SNMPVALUE} (LLD) | <p>-</p> | <p>Expression: {ZBX-INFINERA-XTM-SERIES-MONITORING:oaIfPumpLaserTempLow[{#SNMPVALUE}].last(#1)}<>1</p><p>Recovery expression: </p> | warning | |
[10.002] CU SFP/II | High Rx Optical Power on {#SNMPVALUE} : {ITEM.VALUE2} (LLD) | <p>-</p> | <p>Expression: {ZBX-INFINERA-XTM-SERIES-MONITORING:dcnIfReceivedPowerHigh[{#SNMPVALUE}].last(#1)}<>1 and {ZBX-INFINERA-XTM-SERIES-MONITORING:dcnIfDescr[{#SNMPVALUE}].str(this_does_not_exist)}=0</p><p>Recovery expression: </p> | high |
[10.002] CU SFP/II | Low Rx Optical Power on {#SNMPVALUE} : {ITEM.VALUE2} (LLD) | <p>-</p> | <p>Expression: {ZBX-INFINERA-XTM-SERIES-MONITORING:dcnIfReceivedPowerLow[{#SNMPVALUE}].last(#1)}<>1 and {ZBX-INFINERA-XTM-SERIES-MONITORING:dcnIfDescr[{#SNMPVALUE}].str(this_does_not_exist)}=0</p><p>Recovery expression: </p> | warning |
[10.005] EMXP240/IIE | Error Propagation Active on {#SNMPVALUE} (LLD) | <p>-</p> | <p>Expression: {ZBX-INFINERA-XTM-SERIES-MONITORING:mesErrorPropFault[{#SNMPVALUE}].last(#1)}<>1</p><p>Recovery expression: </p> | warning |
README: https://github.com/hacktivism-github/zbx-templates-repository/blob/master/zbx-infinera/README.md
Bruno Teixeira
There are no macros links in this template.
There are no template links in this template.
Name | Description | Type | Key and additional info |
---|---|---|---|
XTM Series::PM EthTD::Current Meters and Configuration | <p>-</p> | SNMP agent |
pmEthTdName<p>Update: 300</p> |
XTM Series::Metro Ethernet Services | <p>-</p> | SNMP agent |
mesErrorPropName<p>Update: 30</p> |
XTM Series::Equipment Status::Fan status | <p>-</p> | SNMP agent |
equipmentFanName<p>Update: 300</p> |
XTM Series::Equipment Status::Power Supply Status | <p>-</p> | SNMP agent |
equipmentPowerName<p>Update: 300</p> |
XTM Series::Client Interfaces::EMXPxxx | <p>-</p> | SNMP agent |
clientIfName<p>Update: 300</p> |
XTM Series::Optical Amplifiers | <p>-</p> | SNMP agent |
oaIfName<p>Update: 300</p> |
XTM Series::PM Rx/Tx Power Levels::Current Meters and Configuration | <p>-</p> | SNMP agent |
pmIfName<p>Update: 300</p> |
XTM Series::Equipment Status::Board Configuration and Status | <p>-</p> | SNMP agent |
equipmentBoardName<p>Update: 300</p> |
XTM Series::DCN::CU SFP/II::Optical Supervisory Channel | <p>-</p> | SNMP agent |
dcnIfName<p>Update: 300</p> |
XTM Series::Equipment Status::Subrack Status | <p>-</p> | SNMP agent |
equipmentSubrackName<p>Update: 300</p> |
Name | Description | Type | Key and additional info | ||
---|---|---|---|---|---|
XTM Series | Unsaved Changes Alarm | <p>-</p> | SNMP agent |
backupGeneralUnsavedChangesAlarm<p>Update: 300</p> | |
XTM Series | Rx Ethernet Traffic Data on $1 | <p>-</p> | SNMP agent |
pmEthTdCurrentContRxOctets[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | Tx Ethernet Traffic Data on $1 | <p>-</p> | SNMP agent |
pmEthTdCurrentContTxOctets[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | pmEthTdName $1 | <p>-</p> | SNMP agent |
pmEthTdName[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | MES Error Propagation Fault on $1 | <p>-</p> | SNMP agent |
mesErrorPropFault[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | equipmentFanName $1 | <p>-</p> | SNMP agent |
equipmentFanName[{#SNMPVALUE}]<p>Update: 86400</p><p>LLD</p> | |
XTM Series | equipmentFanOperStatus $1 | <p>-</p> | SNMP agent |
equipmentFanOperStatus[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | equipmentFanUnitFailed $1 | <p>-</p> | SNMP agent |
equipmentFanUnitFailed[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | equipmentPowerDCPowerFailedSeverity $1 | <p>-</p> | SNMP agent |
equipmentPowerDCPowerFailedSeverity[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | equipmentPowerDCPowerFailed $1 | <p>-</p> | SNMP agent |
equipmentPowerDCPowerFailed[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | equipmentPowerName $1 | <p>-</p> | SNMP agent |
equipmentPowerName[{#SNMPVALUE}]<p>Update: 86400</p><p>LLD</p> | |
XTM Series | equipmentPowerOperStatus $1 | <p>-</p> | SNMP agent |
equipmentPowerOperStatus[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | equipmentPowerType $1 | <p>-</p> | SNMP agent |
equipmentPowerType[{#SNMPVALUE}]<p>Update: 86400</p><p>LLD</p> | |
XTM Series | clientIfAdminStatus $1 | <p>-</p> | SNMP agent |
clientIfAdminStatus[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | Description on interface $1 | <p>-</p> | SNMP agent |
clientIfDescr[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
TM-3000/II Chassis | clientIfLossOfSignal $1 | <p>-</p> | SNMP agent |
clientIfLossOfSignal[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
TM-3000/II Chassis | clientIfName $1 | <p>-</p> | SNMP agent |
clientIfName[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | clientIfOperStatus $1 | <p>-</p> | SNMP agent |
clientIfOperStatus[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | clientIfPowerLevelLowRelativeThreshold $1 | <p>-</p> | SNMP agent |
clientIfPowerLevelLowRelativeThreshold[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | clientIfPowerLevel $1 | <p>-</p> | SNMP agent |
clientIfPowerLevel[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
TM-3000/II Chassis | clientIfReceivedPowerHigh $1 | <p>-</p> | SNMP agent |
clientIfReceivedPowerHigh[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
TM-3000/II Chassis | clientIfReceivedPowerLow on $1 | <p>-</p> | SNMP agent |
clientIfReceivedPowerLow[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | clientIfReceiverSensitivity $1 | <p>LUM-CLIENT-MIB::clientIfReceiverSensitivity The lowest power that the receiver is guaranteed to handle, in units of 0.1 dBm.</p> | SNMP agent |
clientIfReceiverSensitivity[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | clientIfRxSignalStatus $1 | <p>-</p> | SNMP agent |
clientIfRxSignalStatus[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | OA Adminintrative State for the interface $1 | <p>-</p> | SNMP agent |
oaIfAdminStatus[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | OA interface Description for $1 | <p>-</p> | SNMP agent |
oaIfDescr[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | OA Laser Bias High on $1 | <p>-</p> | SNMP agent |
oaIfLaserBiasHigh[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | OA Loss Of Signal on $1 | <p>-</p> | SNMP agent |
oaIfLossOfSignal[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | OA interface $1 | <p>-</p> | SNMP agent |
oaIfName.me[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | OA Operational State for the interface $1 | <p>-</p> | SNMP agent |
oaIfOperStatus[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | OA Output Power Fail on $1 | <p>-</p> | SNMP agent |
oaIfOutputPowerFail[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | OA Pump Laser Temp Low on $1 | <p>-</p> | SNMP agent |
oaIfPumpLaserTempLow[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | OA Received Power Low on $1 | <p>-</p> | SNMP agent |
oaIfReceivedPowerLow[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | OA Rx Power Level Low Threshold on $1 | <p>-</p> | SNMP agent |
oaIfRxPowerLevelLowThreshold[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | OA Rx power level on $1 | <p>-</p> | SNMP agent |
oaIfRxPowerLevel[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | OA Saturation Fault on $1 | <p>-</p> | SNMP agent |
oaIfSaturationFault[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | OA Tx Power Level Low Threshold on $1 | <p>-</p> | SNMP agent |
oaIfTxPowerLevelLowThreshold[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | OA Tx power level on $1 | <p>-</p> | SNMP agent |
oaIfTxPowerLevel[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | pmIfAdminStatus $1 | <p>-</p> | SNMP agent |
pmIfAdminStatus[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | pmIfName $1 | <p>-</p> | SNMP agent |
pmIfName[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | pmIfOperStatus $1 | <p>-</p> | SNMP agent |
pmIfOperStatus[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | pmIfRx24hCurrentUAS on $1 | <p>-</p> | SNMP agent |
pmIfRx24hCurrentUAS[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | pmIfRx24hUASThreshold on $1 | <p>-</p> | SNMP agent |
pmIfRx24hUASThreshold[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | pmIfRx24hUAS on $1 | <p>-</p> | SNMP agent |
pmIfRx24hUAS[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | Rx Power Level on $1 | <p>-</p> | SNMP agent |
pmIfRxPowerLevel[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | pmIfTx24hCurrentUAS on $1 | <p>-</p> | SNMP agent |
pmIfTx24hCurrentUAS[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | pmIfTx24hUASThreshold on $1 | <p>-</p> | SNMP agent |
pmIfTx24hUASThreshold[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | pmIfTx24hUAS on $1 | <p>-</p> | SNMP agent |
pmIfTx24hUAS[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | Tx Power Level on $1 | <p>-</p> | SNMP agent |
pmIfTxPowerLevel[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | CU-SFP/II | Communication Failure on $1 | <p>-</p> | SNMP agent |
equipmentBoardCommunicationFailure[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> |
XTM Series | equipmentBoardName $1 | <p>-</p> | SNMP agent |
equipmentBoardName[{#SNMPVALUE}]<p>Update: 86400</p><p>LLD</p> | |
XTM Series | equipmentBoardOperStatus $1 | <p>-</p> | SNMP agent |
equipmentBoardOperStatus[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | Secondary DC Power Failed on $1 | <p>-</p> | SNMP agent |
equipmentBoardSecondaryPowerFailed[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | High Board Temperature on $1 | <p>-</p> | SNMP agent |
equipmentBoardTempHighExceeded[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | Equipment Board Temp Low Threshold on $1 | <p>-</p> | SNMP agent |
equipmentBoardTempLowThreshold[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | Equipment Board Temp Low on $1 | <p>-</p> | SNMP agent |
equipmentBoardTempLow[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | Equipment Board Temp Threshold on $1 | <p>-</p> | SNMP agent |
equipmentBoardTempThreshold[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | Equipment Board Temp Very High on $1 | <p>-</p> | SNMP agent |
equipmentBoardTempVeryHigh[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | equipmentBoardUnderMaintenance $1 | <p>-</p> | SNMP agent |
equipmentBoardUnderMaintenance[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
TM-3000/II Chassis | CU SFP/II | dcnIfDescr $1 | <p>-</p> | SNMP agent |
dcnIfDescr[{#SNMPVALUE}]<p>Update: 3600</p><p>LLD</p> |
TM-3000/II Chassis | CU SFP/II | dcnIfName $1 | <p>-</p> | SNMP agent |
dcnIfName[{#SNMPVALUE}]<p>Update: 3600</p><p>LLD</p> |
TM-3000/II Chassis | CU SFP/II | dcnIfOperStatus $1 | <p>-</p> | SNMP agent |
dcnIfOperStatus[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> |
TM-3000/II Chassis | CU SFP/II | dcnIfPowerLevel $1 | <p>-</p> | SNMP agent |
dcnIfPowerLevel[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> |
TM-3000/II Chassis | CU SFP/II | dcnIfReceivedPowerHigh $1 | <p>-</p> | SNMP agent |
dcnIfReceivedPowerHigh[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> |
TM-3000/II Chassis | CU SFP/II | dcnIfReceivedPowerLow $1 | <p>-</p> | SNMP agent |
dcnIfReceivedPowerLow[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> |
XTM Series | equipmentSubrackName $1 | <p>-</p> | SNMP agent |
equipmentSubrackName[{#SNMPVALUE}]<p>Update: 86400</p><p>LLD</p> | |
XTM Series | equipmentSubrackOperStatus on $1 | <p>-</p> | SNMP agent |
equipmentSubrackOperStatus[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | equipmentSubrackTempHighExceeded on $1 | <p>-</p> | SNMP agent |
equipmentSubrackTempHighExceeded[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | Equipment Subrack Temperature Threshold on $1 | <p>-</p> | SNMP agent |
equipmentSubrackTempThreshold[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | Equipment Subrack Temperature on $1 | <p>-</p> | SNMP agent |
equipmentSubrackTemp[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> |
Name | Description | Expression | Priority | |
---|---|---|---|---|
[10.002] EMXP240/IIE | Low Rx Optical Power on {#SNMPVALUE} : {ITEM.VALUE2} | <p>-</p> | <p>Expression: last(/ZBX-INFINERA-XTM-SERIES-MONITORING/clientIfReceivedPowerLow[{#SNMPVALUE}],#1)<>1 and find(/ZBX-INFINERA-XTM-SERIES-MONITORING/clientIfDescr[{#SNMPVALUE}],,”like”,”this_does_not_exist”)=0</p><p>Recovery expression: </p> | warning |
[10.002] High Rx Optical Power on {#SNMPVALUE} | <p>-</p> | <p>Expression: last(/ZBX-INFINERA-XTM-SERIES-MONITORING/clientIfPowerLevel[{#SNMPVALUE}],#1)>=-10</p><p>Recovery expression: </p> | high | |
[10.002] Low Rx Optical Power on {#SNMPVALUE} | <p>-</p> | <p>Expression: last(/ZBX-INFINERA-XTM-SERIES-MONITORING/clientIfPowerLevel[{#SNMPVALUE}],#1)<=-9</p><p>Recovery expression: </p> | warning | |
[10.003] EMXP240/IIE | Loss of Signal on {#SNMPVALUE} : {ITEM.VALUE2} | <p>-</p> | <p>Expression: last(/ZBX-INFINERA-XTM-SERIES-MONITORING/clientIfLossOfSignal[{#SNMPVALUE}],#1)<>1 and find(/ZBX-INFINERA-XTM-SERIES-MONITORING/clientIfDescr[{#SNMPVALUE}],,”like”,”this_does_not_exist”)=0</p><p>Recovery expression: </p> | high |
[10.002] CU SFP/II | High Rx Optical Power on {#SNMPVALUE} : {ITEM.VALUE2} | <p>-</p> | <p>Expression: last(/ZBX-INFINERA-XTM-SERIES-MONITORING/dcnIfReceivedPowerHigh[{#SNMPVALUE}],#1)<>1 and find(/ZBX-INFINERA-XTM-SERIES-MONITORING/dcnIfDescr[{#SNMPVALUE}],,”like”,”this_does_not_exist”)=0</p><p>Recovery expression: </p> | high |
[10.002] CU SFP/II | Low Rx Optical Power on {#SNMPVALUE} : {ITEM.VALUE2} | <p>-</p> | <p>Expression: last(/ZBX-INFINERA-XTM-SERIES-MONITORING/dcnIfReceivedPowerLow[{#SNMPVALUE}],#1)<>1 and find(/ZBX-INFINERA-XTM-SERIES-MONITORING/dcnIfDescr[{#SNMPVALUE}],,”like”,”this_does_not_exist”)=0</p><p>Recovery expression: </p> | warning |
[10.004] Board Under Maintenance {#SNMPVALUE} | <p>-</p> | <p>Expression: last(/ZBX-INFINERA-XTM-SERIES-MONITORING/equipmentBoardUnderMaintenance[{#SNMPVALUE}],#1)<>1</p><p>Recovery expression: </p> | information | |
[] CU SFP/II Communication Failure with {#SNMPVALUE} | <p>-</p> | <p>Expression: last(/ZBX-INFINERA-XTM-SERIES-MONITORING/equipmentBoardCommunicationFailure[{#SNMPVALUE}],#1)<>1</p><p>Recovery expression: </p> | high | |
[] Equipment Board Temperature Very High on {#SNMPVALUE} | <p>-</p> | <p>Expression: last(/ZBX-INFINERA-XTM-SERIES-MONITORING/equipmentBoardTempVeryHigh[{#SNMPVALUE}],#1)<>1</p><p>Recovery expression: </p> | warning | |
[] High Board Temperature on {#SNMPVALUE} | <p>-</p> | <p>Expression: last(/ZBX-INFINERA-XTM-SERIES-MONITORING/equipmentBoardTempHighExceeded[{#SNMPVALUE}],#1)<>1</p><p>Recovery expression: </p> | high | |
[] Secondary DC Power Failed on {#SNMPVALUE} | <p>-</p> | <p>Expression: last(/ZBX-INFINERA-XTM-SERIES-MONITORING/equipmentBoardSecondaryPowerFailed[{#SNMPVALUE}],#1)<>1</p><p>Recovery expression: </p> | high | |
[02.009] {#SNMPVALUE} Fan Unit Failed | <p>-</p> | <p>Expression: last(/ZBX-INFINERA-XTM-SERIES-MONITORING/equipmentFanUnitFailed[{#SNMPVALUE}],#1)<>1</p><p>Recovery expression: </p> | warning | |
[04.104] {#SNMPVALUE} DC Power Supply Failed | <p>-</p> | <p>Expression: last(/ZBX-INFINERA-XTM-SERIES-MONITORING/equipmentPowerDCPowerFailed[{#SNMPVALUE}],#1)<>1</p><p>Recovery expression: </p> | high | |
[02.010] High Subrack Temperature $1 | <p>-</p> | <p>Expression: last(/ZBX-INFINERA-XTM-SERIES-MONITORING/equipmentSubrackTempHighExceeded[{#SNMPVALUE}],#1)<>1</p><p>Recovery expression: </p> | warning | |
[10.005] EMXP240/IIE | Error Propagation Active on {#SNMPVALUE} | <p>-</p> | <p>Expression: last(/ZBX-INFINERA-XTM-SERIES-MONITORING/mesErrorPropFault[{#SNMPVALUE}],#1)<>1</p><p>Recovery expression: </p> | warning |
[10.003] OA2 LG 20/20C | Loss of Signal on interface {#SNMPVALUE} : {ITEM.VALUE2} | <p>-</p> | <p>Expression: last(/ZBX-INFINERA-XTM-SERIES-MONITORING/oaIfLossOfSignal[{#SNMPVALUE}],#1)<>1 and find(/ZBX-INFINERA-XTM-SERIES-MONITORING/oaIfDescr[{#SNMPVALUE}],,”like”,”this_does_not_exist”)=0</p><p>Recovery expression: </p> | high |
[10.006] OA Low Received Optical Power on {#SNMPVALUE} | <p>-</p> | <p>Expression: last(/ZBX-INFINERA-XTM-SERIES-MONITORING/oaIfReceivedPowerLow[{#SNMPVALUE}],#1)<>1</p><p>Recovery expression: </p> | warning | |
[] OA Amplifier Saturation alarm on {#SNMPVALUE} | <p>-</p> | <p>Expression: last(/ZBX-INFINERA-XTM-SERIES-MONITORING/oaIfSaturationFault[{#SNMPVALUE}],#1)<>1</p><p>Recovery expression: </p> | information | |
[] OA High Laser Bias on {#SNMPVALUE} | <p>-</p> | <p>Expression: last(/ZBX-INFINERA-XTM-SERIES-MONITORING/oaIfLaserBiasHigh[{#SNMPVALUE}],#1)<>1</p><p>Recovery expression: </p> | information | |
[] OA interface {#SNMPVALUE} changed its Operational state to DOWN | <p>-</p> | <p>Expression: last(/ZBX-INFINERA-XTM-SERIES-MONITORING/oaIfOperStatus[{#SNMPVALUE}],#1)<>3</p><p>Recovery expression: </p> | high | |
[] OA Output power failed on {#SNMPVALUE} | <p>-</p> | <p>Expression: last(/ZBX-INFINERA-XTM-SERIES-MONITORING/oaIfOutputPowerFail[{#SNMPVALUE}],#1)<>1</p><p>Recovery expression: </p> | high | |
[] OA Pump Laser Temp Low on {#SNMPVALUE} | <p>-</p> | <p>Expression: last(/ZBX-INFINERA-XTM-SERIES-MONITORING/oaIfPumpLaserTempLow[{#SNMPVALUE}],#1)<>1</p><p>Recovery expression: </p> | warning | |
UAS Rx 24 hour Threshold Exceeded on {#SNMPVALUE} | <p>-</p> | <p>Expression: last(/ZBX-INFINERA-XTM-SERIES-MONITORING/pmIfRx24hCurrentUAS[{#SNMPVALUE}],#1)>300</p><p>Recovery expression: </p> | warning | |
UAS Tx 24 hour Threshold Exceeded on {#SNMPVALUE} | <p>-</p> | <p>Expression: last(/ZBX-INFINERA-XTM-SERIES-MONITORING/pmIfAdminStatus[{#SNMPVALUE}],#1)=2 or last(/ZBX-INFINERA-XTM-SERIES-MONITORING/pmIfAdminStatus[{#SNMPVALUE}],#1)=3 and last(/ZBX-INFINERA-XTM-SERIES-MONITORING/pmIfTx24hCurrentUAS[{#SNMPVALUE}],#1)>300</p><p>Recovery expression: </p> | warning | |
[10.005] EMXP240/IIE | Error Propagation Active on {#SNMPVALUE} (LLD) | <p>-</p> | <p>Expression: last(/ZBX-INFINERA-XTM-SERIES-MONITORING/mesErrorPropFault[{#SNMPVALUE}],#1)<>1</p><p>Recovery expression: </p> | warning |
[02.009] {#SNMPVALUE} Fan Unit Failed (LLD) | <p>-</p> | <p>Expression: last(/ZBX-INFINERA-XTM-SERIES-MONITORING/equipmentFanUnitFailed[{#SNMPVALUE}],#1)<>1</p><p>Recovery expression: </p> | warning | |
[04.104] {#SNMPVALUE} DC Power Supply Failed (LLD) | <p>-</p> | <p>Expression: last(/ZBX-INFINERA-XTM-SERIES-MONITORING/equipmentPowerDCPowerFailed[{#SNMPVALUE}],#1)<>1</p><p>Recovery expression: </p> | high | |
[10.002] EMXP240/IIE | Low Rx Optical Power on {#SNMPVALUE} : {ITEM.VALUE2} (LLD) | <p>-</p> | <p>Expression: last(/ZBX-INFINERA-XTM-SERIES-MONITORING/clientIfReceivedPowerLow[{#SNMPVALUE}],#1)<>1 and find(/ZBX-INFINERA-XTM-SERIES-MONITORING/clientIfDescr[{#SNMPVALUE}],,”like”,”this_does_not_exist”)=0</p><p>Recovery expression: </p> | warning |
[10.002] High Rx Optical Power on {#SNMPVALUE} (LLD) | <p>-</p> | <p>Expression: last(/ZBX-INFINERA-XTM-SERIES-MONITORING/clientIfPowerLevel[{#SNMPVALUE}],#1)>=-10</p><p>Recovery expression: </p> | high | |
[10.002] Low Rx Optical Power on {#SNMPVALUE} (LLD) | <p>-</p> | <p>Expression: last(/ZBX-INFINERA-XTM-SERIES-MONITORING/clientIfPowerLevel[{#SNMPVALUE}],#1)<=-9</p><p>Recovery expression: </p> | warning | |
[10.003] EMXP240/IIE | Loss of Signal on {#SNMPVALUE} : {ITEM.VALUE2} (LLD) | <p>-</p> | <p>Expression: last(/ZBX-INFINERA-XTM-SERIES-MONITORING/clientIfLossOfSignal[{#SNMPVALUE}],#1)<>1 and find(/ZBX-INFINERA-XTM-SERIES-MONITORING/clientIfDescr[{#SNMPVALUE}],,”like”,”this_does_not_exist”)=0</p><p>Recovery expression: </p> | high |
[10.003] OA2 LG 20/20C | Loss of Signal on interface {#SNMPVALUE} : {ITEM.VALUE2} (LLD) | <p>-</p> | <p>Expression: last(/ZBX-INFINERA-XTM-SERIES-MONITORING/oaIfLossOfSignal[{#SNMPVALUE}],#1)<>1 and find(/ZBX-INFINERA-XTM-SERIES-MONITORING/oaIfDescr[{#SNMPVALUE}],,”like”,”this_does_not_exist”)=0</p><p>Recovery expression: </p> | high |
[10.006] OA Low Received Optical Power on {#SNMPVALUE} (LLD) | <p>-</p> | <p>Expression: last(/ZBX-INFINERA-XTM-SERIES-MONITORING/oaIfReceivedPowerLow[{#SNMPVALUE}],#1)<>1</p><p>Recovery expression: </p> | warning | |
[] OA Amplifier Saturation alarm on {#SNMPVALUE} (LLD) | <p>-</p> | <p>Expression: last(/ZBX-INFINERA-XTM-SERIES-MONITORING/oaIfSaturationFault[{#SNMPVALUE}],#1)<>1</p><p>Recovery expression: </p> | information | |
[] OA High Laser Bias on {#SNMPVALUE} (LLD) | <p>-</p> | <p>Expression: last(/ZBX-INFINERA-XTM-SERIES-MONITORING/oaIfLaserBiasHigh[{#SNMPVALUE}],#1)<>1</p><p>Recovery expression: </p> | information | |
[] OA interface {#SNMPVALUE} changed its Operational state to DOWN (LLD) | <p>-</p> | <p>Expression: last(/ZBX-INFINERA-XTM-SERIES-MONITORING/oaIfOperStatus[{#SNMPVALUE}],#1)<>3</p><p>Recovery expression: </p> | high | |
[] OA Output power failed on {#SNMPVALUE} (LLD) | <p>-</p> | <p>Expression: last(/ZBX-INFINERA-XTM-SERIES-MONITORING/oaIfOutputPowerFail[{#SNMPVALUE}],#1)<>1</p><p>Recovery expression: </p> | high | |
[] OA Pump Laser Temp Low on {#SNMPVALUE} (LLD) | <p>-</p> | <p>Expression: last(/ZBX-INFINERA-XTM-SERIES-MONITORING/oaIfPumpLaserTempLow[{#SNMPVALUE}],#1)<>1</p><p>Recovery expression: </p> | warning | |
UAS Rx 24 hour Threshold Exceeded on {#SNMPVALUE} (LLD) | <p>-</p> | <p>Expression: last(/ZBX-INFINERA-XTM-SERIES-MONITORING/pmIfRx24hCurrentUAS[{#SNMPVALUE}],#1)>300</p><p>Recovery expression: </p> | warning | |
UAS Tx 24 hour Threshold Exceeded on {#SNMPVALUE} (LLD) | <p>-</p> | <p>Expression: last(/ZBX-INFINERA-XTM-SERIES-MONITORING/pmIfAdminStatus[{#SNMPVALUE}],#1)=2 or last(/ZBX-INFINERA-XTM-SERIES-MONITORING/pmIfAdminStatus[{#SNMPVALUE}],#1)=3 and last(/ZBX-INFINERA-XTM-SERIES-MONITORING/pmIfTx24hCurrentUAS[{#SNMPVALUE}],#1)>300</p><p>Recovery expression: </p> | warning | |
[10.004] Board Under Maintenance {#SNMPVALUE} (LLD) | <p>-</p> | <p>Expression: last(/ZBX-INFINERA-XTM-SERIES-MONITORING/equipmentBoardUnderMaintenance[{#SNMPVALUE}],#1)<>1</p><p>Recovery expression: </p> | information | |
[] CU SFP/II Communication Failure with {#SNMPVALUE} (LLD) | <p>-</p> | <p>Expression: last(/ZBX-INFINERA-XTM-SERIES-MONITORING/equipmentBoardCommunicationFailure[{#SNMPVALUE}],#1)<>1</p><p>Recovery expression: </p> | high | |
[] Equipment Board Temperature Very High on {#SNMPVALUE} (LLD) | <p>-</p> | <p>Expression: last(/ZBX-INFINERA-XTM-SERIES-MONITORING/equipmentBoardTempVeryHigh[{#SNMPVALUE}],#1)<>1</p><p>Recovery expression: </p> | warning | |
[] High Board Temperature on {#SNMPVALUE} (LLD) | <p>-</p> | <p>Expression: last(/ZBX-INFINERA-XTM-SERIES-MONITORING/equipmentBoardTempHighExceeded[{#SNMPVALUE}],#1)<>1</p><p>Recovery expression: </p> | high | |
[] Secondary DC Power Failed on {#SNMPVALUE} (LLD) | <p>-</p> | <p>Expression: last(/ZBX-INFINERA-XTM-SERIES-MONITORING/equipmentBoardSecondaryPowerFailed[{#SNMPVALUE}],#1)<>1</p><p>Recovery expression: </p> | high | |
[10.002] CU SFP/II | High Rx Optical Power on {#SNMPVALUE} : {ITEM.VALUE2} (LLD) | <p>-</p> | <p>Expression: last(/ZBX-INFINERA-XTM-SERIES-MONITORING/dcnIfReceivedPowerHigh[{#SNMPVALUE}],#1)<>1 and find(/ZBX-INFINERA-XTM-SERIES-MONITORING/dcnIfDescr[{#SNMPVALUE}],,”like”,”this_does_not_exist”)=0</p><p>Recovery expression: </p> | high |
[10.002] CU SFP/II | Low Rx Optical Power on {#SNMPVALUE} : {ITEM.VALUE2} (LLD) | <p>-</p> | <p>Expression: last(/ZBX-INFINERA-XTM-SERIES-MONITORING/dcnIfReceivedPowerLow[{#SNMPVALUE}],#1)<>1 and find(/ZBX-INFINERA-XTM-SERIES-MONITORING/dcnIfDescr[{#SNMPVALUE}],,”like”,”this_does_not_exist”)=0</p><p>Recovery expression: </p> | warning |
[02.010] High Subrack Temperature $1 (LLD) | <p>-</p> | <p>Expression: last(/ZBX-INFINERA-XTM-SERIES-MONITORING/equipmentSubrackTempHighExceeded[{#SNMPVALUE}],#1)<>1</p><p>Recovery expression: </p> | warning |
README: https://github.com/hacktivism-github/zbx-templates-repository/blob/master/zbx-infinera/README.md
Bruno Teixeira
There are no macros links in this template.
There are no template links in this template.
Name | Description | Type | Key and additional info |
---|---|---|---|
XTM Series::PM EthTD::Current Meters and Configuration | <p>-</p> | SNMP agent |
pmEthTdName<p>Update: 300</p> |
XTM Series::Metro Ethernet Services | <p>-</p> | SNMP agent |
mesErrorPropName<p>Update: 30</p> |
XTM Series::Equipment Status::Fan status | <p>-</p> | SNMP agent |
equipmentFanName<p>Update: 300</p> |
XTM Series::Equipment Status::Power Supply Status | <p>-</p> | SNMP agent |
equipmentPowerName<p>Update: 300</p> |
XTM Series::Client Interfaces::EMXPxxx | <p>-</p> | SNMP agent |
clientIfName<p>Update: 300</p> |
XTM Series::Optical Amplifiers | <p>-</p> | SNMP agent |
oaIfName<p>Update: 300</p> |
XTM Series::PM Rx/Tx Power Levels::Current Meters and Configuration | <p>-</p> | SNMP agent |
pmIfName<p>Update: 300</p> |
XTM Series::Equipment Status::Board Configuration and Status | <p>-</p> | SNMP agent |
equipmentBoardName<p>Update: 300</p> |
XTM Series::DCN::CU SFP/II::Optical Supervisory Channel | <p>-</p> | SNMP agent |
dcnIfName<p>Update: 300</p> |
XTM Series::Equipment Status::Subrack Status | <p>-</p> | SNMP agent |
equipmentSubrackName<p>Update: 300</p> |
Name | Description | Type | Key and additional info | ||
---|---|---|---|---|---|
XTM Series | Unsaved Changes Alarm | <p>-</p> | SNMP agent |
backupGeneralUnsavedChangesAlarm<p>Update: 300</p> | |
XTM Series | Rx Ethernet Traffic Data on $1 | <p>-</p> | SNMP agent |
pmEthTdCurrentContRxOctets[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | Tx Ethernet Traffic Data on $1 | <p>-</p> | SNMP agent |
pmEthTdCurrentContTxOctets[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | pmEthTdName $1 | <p>-</p> | SNMP agent |
pmEthTdName[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | MES Error Propagation Fault on $1 | <p>-</p> | SNMP agent |
mesErrorPropFault[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | equipmentFanName $1 | <p>-</p> | SNMP agent |
equipmentFanName[{#SNMPVALUE}]<p>Update: 86400</p><p>LLD</p> | |
XTM Series | equipmentFanOperStatus $1 | <p>-</p> | SNMP agent |
equipmentFanOperStatus[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | equipmentFanUnitFailed $1 | <p>-</p> | SNMP agent |
equipmentFanUnitFailed[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | equipmentPowerDCPowerFailedSeverity $1 | <p>-</p> | SNMP agent |
equipmentPowerDCPowerFailedSeverity[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | equipmentPowerDCPowerFailed $1 | <p>-</p> | SNMP agent |
equipmentPowerDCPowerFailed[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | equipmentPowerName $1 | <p>-</p> | SNMP agent |
equipmentPowerName[{#SNMPVALUE}]<p>Update: 86400</p><p>LLD</p> | |
XTM Series | equipmentPowerOperStatus $1 | <p>-</p> | SNMP agent |
equipmentPowerOperStatus[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | equipmentPowerType $1 | <p>-</p> | SNMP agent |
equipmentPowerType[{#SNMPVALUE}]<p>Update: 86400</p><p>LLD</p> | |
XTM Series | clientIfAdminStatus $1 | <p>-</p> | SNMP agent |
clientIfAdminStatus[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | Description on interface $1 | <p>-</p> | SNMP agent |
clientIfDescr[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
TM-3000/II Chassis | clientIfLossOfSignal $1 | <p>-</p> | SNMP agent |
clientIfLossOfSignal[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
TM-3000/II Chassis | clientIfName $1 | <p>-</p> | SNMP agent |
clientIfName[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | clientIfOperStatus $1 | <p>-</p> | SNMP agent |
clientIfOperStatus[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | clientIfPowerLevelLowRelativeThreshold $1 | <p>-</p> | SNMP agent |
clientIfPowerLevelLowRelativeThreshold[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | clientIfPowerLevel $1 | <p>-</p> | SNMP agent |
clientIfPowerLevel[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
TM-3000/II Chassis | clientIfReceivedPowerHigh $1 | <p>-</p> | SNMP agent |
clientIfReceivedPowerHigh[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
TM-3000/II Chassis | clientIfReceivedPowerLow on $1 | <p>-</p> | SNMP agent |
clientIfReceivedPowerLow[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | clientIfReceiverSensitivity $1 | <p>LUM-CLIENT-MIB::clientIfReceiverSensitivity The lowest power that the receiver is guaranteed to handle, in units of 0.1 dBm.</p> | SNMP agent |
clientIfReceiverSensitivity[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | clientIfRxSignalStatus $1 | <p>-</p> | SNMP agent |
clientIfRxSignalStatus[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | OA Adminintrative State for the interface $1 | <p>-</p> | SNMP agent |
oaIfAdminStatus[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | OA interface Description for $1 | <p>-</p> | SNMP agent |
oaIfDescr[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | OA Laser Bias High on $1 | <p>-</p> | SNMP agent |
oaIfLaserBiasHigh[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | OA Loss Of Signal on $1 | <p>-</p> | SNMP agent |
oaIfLossOfSignal[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | OA interface $1 | <p>-</p> | SNMP agent |
oaIfName.me[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | OA Operational State for the interface $1 | <p>-</p> | SNMP agent |
oaIfOperStatus[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | OA Output Power Fail on $1 | <p>-</p> | SNMP agent |
oaIfOutputPowerFail[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | OA Pump Laser Temp Low on $1 | <p>-</p> | SNMP agent |
oaIfPumpLaserTempLow[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | OA Received Power Low on $1 | <p>-</p> | SNMP agent |
oaIfReceivedPowerLow[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | OA Rx Power Level Low Threshold on $1 | <p>-</p> | SNMP agent |
oaIfRxPowerLevelLowThreshold[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | OA Rx power level on $1 | <p>-</p> | SNMP agent |
oaIfRxPowerLevel[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | OA Saturation Fault on $1 | <p>-</p> | SNMP agent |
oaIfSaturationFault[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | OA Tx Power Level Low Threshold on $1 | <p>-</p> | SNMP agent |
oaIfTxPowerLevelLowThreshold[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | OA Tx power level on $1 | <p>-</p> | SNMP agent |
oaIfTxPowerLevel[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | pmIfAdminStatus $1 | <p>-</p> | SNMP agent |
pmIfAdminStatus[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | pmIfName $1 | <p>-</p> | SNMP agent |
pmIfName[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | pmIfOperStatus $1 | <p>-</p> | SNMP agent |
pmIfOperStatus[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | pmIfRx24hCurrentUAS on $1 | <p>-</p> | SNMP agent |
pmIfRx24hCurrentUAS[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | pmIfRx24hUASThreshold on $1 | <p>-</p> | SNMP agent |
pmIfRx24hUASThreshold[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | pmIfRx24hUAS on $1 | <p>-</p> | SNMP agent |
pmIfRx24hUAS[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | Rx Power Level on $1 | <p>-</p> | SNMP agent |
pmIfRxPowerLevel[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | pmIfTx24hCurrentUAS on $1 | <p>-</p> | SNMP agent |
pmIfTx24hCurrentUAS[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | pmIfTx24hUASThreshold on $1 | <p>-</p> | SNMP agent |
pmIfTx24hUASThreshold[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | pmIfTx24hUAS on $1 | <p>-</p> | SNMP agent |
pmIfTx24hUAS[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | Tx Power Level on $1 | <p>-</p> | SNMP agent |
pmIfTxPowerLevel[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | CU-SFP/II | Communication Failure on $1 | <p>-</p> | SNMP agent |
equipmentBoardCommunicationFailure[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> |
XTM Series | equipmentBoardName $1 | <p>-</p> | SNMP agent |
equipmentBoardName[{#SNMPVALUE}]<p>Update: 86400</p><p>LLD</p> | |
XTM Series | equipmentBoardOperStatus $1 | <p>-</p> | SNMP agent |
equipmentBoardOperStatus[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | Secondary DC Power Failed on $1 | <p>-</p> | SNMP agent |
equipmentBoardSecondaryPowerFailed[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | High Board Temperature on $1 | <p>-</p> | SNMP agent |
equipmentBoardTempHighExceeded[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | Equipment Board Temp Low Threshold on $1 | <p>-</p> | SNMP agent |
equipmentBoardTempLowThreshold[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | Equipment Board Temp Low on $1 | <p>-</p> | SNMP agent |
equipmentBoardTempLow[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | Equipment Board Temp Threshold on $1 | <p>-</p> | SNMP agent |
equipmentBoardTempThreshold[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | Equipment Board Temp Very High on $1 | <p>-</p> | SNMP agent |
equipmentBoardTempVeryHigh[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | equipmentBoardUnderMaintenance $1 | <p>-</p> | SNMP agent |
equipmentBoardUnderMaintenance[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
TM-3000/II Chassis | CU SFP/II | dcnIfDescr $1 | <p>-</p> | SNMP agent |
dcnIfDescr[{#SNMPVALUE}]<p>Update: 3600</p><p>LLD</p> |
TM-3000/II Chassis | CU SFP/II | dcnIfName $1 | <p>-</p> | SNMP agent |
dcnIfName[{#SNMPVALUE}]<p>Update: 3600</p><p>LLD</p> |
TM-3000/II Chassis | CU SFP/II | dcnIfOperStatus $1 | <p>-</p> | SNMP agent |
dcnIfOperStatus[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> |
TM-3000/II Chassis | CU SFP/II | dcnIfPowerLevel $1 | <p>-</p> | SNMP agent |
dcnIfPowerLevel[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> |
TM-3000/II Chassis | CU SFP/II | dcnIfReceivedPowerHigh $1 | <p>-</p> | SNMP agent |
dcnIfReceivedPowerHigh[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> |
TM-3000/II Chassis | CU SFP/II | dcnIfReceivedPowerLow $1 | <p>-</p> | SNMP agent |
dcnIfReceivedPowerLow[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> |
XTM Series | equipmentSubrackName $1 | <p>-</p> | SNMP agent |
equipmentSubrackName[{#SNMPVALUE}]<p>Update: 86400</p><p>LLD</p> | |
XTM Series | equipmentSubrackOperStatus on $1 | <p>-</p> | SNMP agent |
equipmentSubrackOperStatus[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | equipmentSubrackTempHighExceeded on $1 | <p>-</p> | SNMP agent |
equipmentSubrackTempHighExceeded[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | Equipment Subrack Temperature Threshold on $1 | <p>-</p> | SNMP agent |
equipmentSubrackTempThreshold[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> | |
XTM Series | Equipment Subrack Temperature on $1 | <p>-</p> | SNMP agent |
equipmentSubrackTemp[{#SNMPVALUE}]<p>Update: 300</p><p>LLD</p> |
Name | Description | Expression | Priority | |
---|---|---|---|---|
[10.002] EMXP240/IIE | Low Rx Optical Power on {#SNMPVALUE} : {ITEM.VALUE2} | <p>-</p> | <p>Expression: last(/ZBX-INFINERA-XTM-SERIES-MONITORING/clientIfReceivedPowerLow[{#SNMPVALUE}],#1)<>1 and find(/ZBX-INFINERA-XTM-SERIES-MONITORING/clientIfDescr[{#SNMPVALUE}],,”like”,”this_does_not_exist”)=0</p><p>Recovery expression: </p> | warning |
[10.002] High Rx Optical Power on {#SNMPVALUE} | <p>-</p> | <p>Expression: last(/ZBX-INFINERA-XTM-SERIES-MONITORING/clientIfPowerLevel[{#SNMPVALUE}],#1)>=-10</p><p>Recovery expression: </p> | high | |
[10.002] Low Rx Optical Power on {#SNMPVALUE} | <p>-</p> | <p>Expression: last(/ZBX-INFINERA-XTM-SERIES-MONITORING/clientIfPowerLevel[{#SNMPVALUE}],#1)<=-9</p><p>Recovery expression: </p> | warning | |
[10.003] EMXP240/IIE | Loss of Signal on {#SNMPVALUE} : {ITEM.VALUE2} | <p>-</p> | <p>Expression: last(/ZBX-INFINERA-XTM-SERIES-MONITORING/clientIfLossOfSignal[{#SNMPVALUE}],#1)<>1 and find(/ZBX-INFINERA-XTM-SERIES-MONITORING/clientIfDescr[{#SNMPVALUE}],,”like”,”this_does_not_exist”)=0</p><p>Recovery expression: </p> | high |
[10.002] CU SFP/II | High Rx Optical Power on {#SNMPVALUE} : {ITEM.VALUE2} | <p>-</p> | <p>Expression: last(/ZBX-INFINERA-XTM-SERIES-MONITORING/dcnIfReceivedPowerHigh[{#SNMPVALUE}],#1)<>1 and find(/ZBX-INFINERA-XTM-SERIES-MONITORING/dcnIfDescr[{#SNMPVALUE}],,”like”,”this_does_not_exist”)=0</p><p>Recovery expression: </p> | high |
[10.002] CU SFP/II | Low Rx Optical Power on {#SNMPVALUE} : {ITEM.VALUE2} | <p>-</p> | <p>Expression: last(/ZBX-INFINERA-XTM-SERIES-MONITORING/dcnIfReceivedPowerLow[{#SNMPVALUE}],#1)<>1 and find(/ZBX-INFINERA-XTM-SERIES-MONITORING/dcnIfDescr[{#SNMPVALUE}],,”like”,”this_does_not_exist”)=0</p><p>Recovery expression: </p> | warning |
[10.004] Board Under Maintenance {#SNMPVALUE} | <p>-</p> | <p>Expression: last(/ZBX-INFINERA-XTM-SERIES-MONITORING/equipmentBoardUnderMaintenance[{#SNMPVALUE}],#1)<>1</p><p>Recovery expression: </p> | information | |
[] CU SFP/II Communication Failure with {#SNMPVALUE} | <p>-</p> | <p>Expression: last(/ZBX-INFINERA-XTM-SERIES-MONITORING/equipmentBoardCommunicationFailure[{#SNMPVALUE}],#1)<>1</p><p>Recovery expression: </p> | high | |
[] Equipment Board Temperature Very High on {#SNMPVALUE} | <p>-</p> | <p>Expression: last(/ZBX-INFINERA-XTM-SERIES-MONITORING/equipmentBoardTempVeryHigh[{#SNMPVALUE}],#1)<>1</p><p>Recovery expression: </p> | warning | |
[] High Board Temperature on {#SNMPVALUE} | <p>-</p> | <p>Expression: last(/ZBX-INFINERA-XTM-SERIES-MONITORING/equipmentBoardTempHighExceeded[{#SNMPVALUE}],#1)<>1</p><p>Recovery expression: </p> | high | |
[] Secondary DC Power Failed on {#SNMPVALUE} | <p>-</p> | <p>Expression: last(/ZBX-INFINERA-XTM-SERIES-MONITORING/equipmentBoardSecondaryPowerFailed[{#SNMPVALUE}],#1)<>1</p><p>Recovery expression: </p> | high | |
[02.009] {#SNMPVALUE} Fan Unit Failed | <p>-</p> | <p>Expression: last(/ZBX-INFINERA-XTM-SERIES-MONITORING/equipmentFanUnitFailed[{#SNMPVALUE}],#1)<>1</p><p>Recovery expression: </p> | warning | |
[04.104] {#SNMPVALUE} DC Power Supply Failed | <p>-</p> | <p>Expression: last(/ZBX-INFINERA-XTM-SERIES-MONITORING/equipmentPowerDCPowerFailed[{#SNMPVALUE}],#1)<>1</p><p>Recovery expression: </p> | high | |
[02.010] High Subrack Temperature $1 | <p>-</p> | <p>Expression: last(/ZBX-INFINERA-XTM-SERIES-MONITORING/equipmentSubrackTempHighExceeded[{#SNMPVALUE}],#1)<>1</p><p>Recovery expression: </p> | warning | |
[10.005] EMXP240/IIE | Error Propagation Active on {#SNMPVALUE} | <p>-</p> | <p>Expression: last(/ZBX-INFINERA-XTM-SERIES-MONITORING/mesErrorPropFault[{#SNMPVALUE}],#1)<>1</p><p>Recovery expression: </p> | warning |
[10.003] OA2 LG 20/20C | Loss of Signal on interface {#SNMPVALUE} : {ITEM.VALUE2} | <p>-</p> | <p>Expression: last(/ZBX-INFINERA-XTM-SERIES-MONITORING/oaIfLossOfSignal[{#SNMPVALUE}],#1)<>1 and find(/ZBX-INFINERA-XTM-SERIES-MONITORING/oaIfDescr[{#SNMPVALUE}],,”like”,”this_does_not_exist”)=0</p><p>Recovery expression: </p> | high |
[10.006] OA Low Received Optical Power on {#SNMPVALUE} | <p>-</p> | <p>Expression: last(/ZBX-INFINERA-XTM-SERIES-MONITORING/oaIfReceivedPowerLow[{#SNMPVALUE}],#1)<>1</p><p>Recovery expression: </p> | warning | |
[] OA Amplifier Saturation alarm on {#SNMPVALUE} | <p>-</p> | <p>Expression: last(/ZBX-INFINERA-XTM-SERIES-MONITORING/oaIfSaturationFault[{#SNMPVALUE}],#1)<>1</p><p>Recovery expression: </p> | information | |
[] OA High Laser Bias on {#SNMPVALUE} | <p>-</p> | <p>Expression: last(/ZBX-INFINERA-XTM-SERIES-MONITORING/oaIfLaserBiasHigh[{#SNMPVALUE}],#1)<>1</p><p>Recovery expression: </p> | information | |
[] OA interface {#SNMPVALUE} changed its Operational state to DOWN | <p>-</p> | <p>Expression: last(/ZBX-INFINERA-XTM-SERIES-MONITORING/oaIfOperStatus[{#SNMPVALUE}],#1)<>3</p><p>Recovery expression: </p> | high | |
[] OA Output power failed on {#SNMPVALUE} | <p>-</p> | <p>Expression: last(/ZBX-INFINERA-XTM-SERIES-MONITORING/oaIfOutputPowerFail[{#SNMPVALUE}],#1)<>1</p><p>Recovery expression: </p> | high | |
[] OA Pump Laser Temp Low on {#SNMPVALUE} | <p>-</p> | <p>Expression: last(/ZBX-INFINERA-XTM-SERIES-MONITORING/oaIfPumpLaserTempLow[{#SNMPVALUE}],#1)<>1</p><p>Recovery expression: </p> | warning | |
UAS Rx 24 hour Threshold Exceeded on {#SNMPVALUE} | <p>-</p> | <p>Expression: last(/ZBX-INFINERA-XTM-SERIES-MONITORING/pmIfRx24hCurrentUAS[{#SNMPVALUE}],#1)>300</p><p>Recovery expression: </p> | warning | |
UAS Tx 24 hour Threshold Exceeded on {#SNMPVALUE} | <p>-</p> | <p>Expression: last(/ZBX-INFINERA-XTM-SERIES-MONITORING/pmIfAdminStatus[{#SNMPVALUE}],#1)=2 or last(/ZBX-INFINERA-XTM-SERIES-MONITORING/pmIfAdminStatus[{#SNMPVALUE}],#1)=3 and last(/ZBX-INFINERA-XTM-SERIES-MONITORING/pmIfTx24hCurrentUAS[{#SNMPVALUE}],#1)>300</p><p>Recovery expression: </p> | warning | |
[10.005] EMXP240/IIE | Error Propagation Active on {#SNMPVALUE} (LLD) | <p>-</p> | <p>Expression: last(/ZBX-INFINERA-XTM-SERIES-MONITORING/mesErrorPropFault[{#SNMPVALUE}],#1)<>1</p><p>Recovery expression: </p> | warning |
[02.009] {#SNMPVALUE} Fan Unit Failed (LLD) | <p>-</p> | <p>Expression: last(/ZBX-INFINERA-XTM-SERIES-MONITORING/equipmentFanUnitFailed[{#SNMPVALUE}],#1)<>1</p><p>Recovery expression: </p> | warning | |
[04.104] {#SNMPVALUE} DC Power Supply Failed (LLD) | <p>-</p> | <p>Expression: last(/ZBX-INFINERA-XTM-SERIES-MONITORING/equipmentPowerDCPowerFailed[{#SNMPVALUE}],#1)<>1</p><p>Recovery expression: </p> | high | |
[10.002] EMXP240/IIE | Low Rx Optical Power on {#SNMPVALUE} : {ITEM.VALUE2} (LLD) | <p>-</p> | <p>Expression: last(/ZBX-INFINERA-XTM-SERIES-MONITORING/clientIfReceivedPowerLow[{#SNMPVALUE}],#1)<>1 and find(/ZBX-INFINERA-XTM-SERIES-MONITORING/clientIfDescr[{#SNMPVALUE}],,”like”,”this_does_not_exist”)=0</p><p>Recovery expression: </p> | warning |
[10.002] High Rx Optical Power on {#SNMPVALUE} (LLD) | <p>-</p> | <p>Expression: last(/ZBX-INFINERA-XTM-SERIES-MONITORING/clientIfPowerLevel[{#SNMPVALUE}],#1)>=-10</p><p>Recovery expression: </p> | high | |
[10.002] Low Rx Optical Power on {#SNMPVALUE} (LLD) | <p>-</p> | <p>Expression: last(/ZBX-INFINERA-XTM-SERIES-MONITORING/clientIfPowerLevel[{#SNMPVALUE}],#1)<=-9</p><p>Recovery expression: </p> | warning | |
[10.003] EMXP240/IIE | Loss of Signal on {#SNMPVALUE} : {ITEM.VALUE2} (LLD) | <p>-</p> | <p>Expression: last(/ZBX-INFINERA-XTM-SERIES-MONITORING/clientIfLossOfSignal[{#SNMPVALUE}],#1)<>1 and find(/ZBX-INFINERA-XTM-SERIES-MONITORING/clientIfDescr[{#SNMPVALUE}],,”like”,”this_does_not_exist”)=0</p><p>Recovery expression: </p> | high |
[10.003] OA2 LG 20/20C | Loss of Signal on interface {#SNMPVALUE} : {ITEM.VALUE2} (LLD) | <p>-</p> | <p>Expression: last(/ZBX-INFINERA-XTM-SERIES-MONITORING/oaIfLossOfSignal[{#SNMPVALUE}],#1)<>1 and find(/ZBX-INFINERA-XTM-SERIES-MONITORING/oaIfDescr[{#SNMPVALUE}],,”like”,”this_does_not_exist”)=0</p><p>Recovery expression: </p> | high |
[10.006] OA Low Received Optical Power on {#SNMPVALUE} (LLD) | <p>-</p> | <p>Expression: last(/ZBX-INFINERA-XTM-SERIES-MONITORING/oaIfReceivedPowerLow[{#SNMPVALUE}],#1)<>1</p><p>Recovery expression: </p> | warning | |
[] OA Amplifier Saturation alarm on {#SNMPVALUE} (LLD) | <p>-</p> | <p>Expression: last(/ZBX-INFINERA-XTM-SERIES-MONITORING/oaIfSaturationFault[{#SNMPVALUE}],#1)<>1</p><p>Recovery expression: </p> | information | |
[] OA High Laser Bias on {#SNMPVALUE} (LLD) | <p>-</p> | <p>Expression: last(/ZBX-INFINERA-XTM-SERIES-MONITORING/oaIfLaserBiasHigh[{#SNMPVALUE}],#1)<>1</p><p>Recovery expression: </p> | information | |
[] OA interface {#SNMPVALUE} changed its Operational state to DOWN (LLD) | <p>-</p> | <p>Expression: last(/ZBX-INFINERA-XTM-SERIES-MONITORING/oaIfOperStatus[{#SNMPVALUE}],#1)<>3</p><p>Recovery expression: </p> | high | |
[] OA Output power failed on {#SNMPVALUE} (LLD) | <p>-</p> | <p>Expression: last(/ZBX-INFINERA-XTM-SERIES-MONITORING/oaIfOutputPowerFail[{#SNMPVALUE}],#1)<>1</p><p>Recovery expression: </p> | high | |
[] OA Pump Laser Temp Low on {#SNMPVALUE} (LLD) | <p>-</p> | <p>Expression: last(/ZBX-INFINERA-XTM-SERIES-MONITORING/oaIfPumpLaserTempLow[{#SNMPVALUE}],#1)<>1</p><p>Recovery expression: </p> | warning | |
UAS Rx 24 hour Threshold Exceeded on {#SNMPVALUE} (LLD) | <p>-</p> | <p>Expression: last(/ZBX-INFINERA-XTM-SERIES-MONITORING/pmIfRx24hCurrentUAS[{#SNMPVALUE}],#1)>300</p><p>Recovery expression: </p> | warning | |
UAS Tx 24 hour Threshold Exceeded on {#SNMPVALUE} (LLD) | <p>-</p> | <p>Expression: last(/ZBX-INFINERA-XTM-SERIES-MONITORING/pmIfAdminStatus[{#SNMPVALUE}],#1)=2 or last(/ZBX-INFINERA-XTM-SERIES-MONITORING/pmIfAdminStatus[{#SNMPVALUE}],#1)=3 and last(/ZBX-INFINERA-XTM-SERIES-MONITORING/pmIfTx24hCurrentUAS[{#SNMPVALUE}],#1)>300</p><p>Recovery expression: </p> | warning | |
[10.004] Board Under Maintenance {#SNMPVALUE} (LLD) | <p>-</p> | <p>Expression: last(/ZBX-INFINERA-XTM-SERIES-MONITORING/equipmentBoardUnderMaintenance[{#SNMPVALUE}],#1)<>1</p><p>Recovery expression: </p> | information | |
[] CU SFP/II Communication Failure with {#SNMPVALUE} (LLD) | <p>-</p> | <p>Expression: last(/ZBX-INFINERA-XTM-SERIES-MONITORING/equipmentBoardCommunicationFailure[{#SNMPVALUE}],#1)<>1</p><p>Recovery expression: </p> | high | |
[] Equipment Board Temperature Very High on {#SNMPVALUE} (LLD) | <p>-</p> | <p>Expression: last(/ZBX-INFINERA-XTM-SERIES-MONITORING/equipmentBoardTempVeryHigh[{#SNMPVALUE}],#1)<>1</p><p>Recovery expression: </p> | warning | |
[] High Board Temperature on {#SNMPVALUE} (LLD) | <p>-</p> | <p>Expression: last(/ZBX-INFINERA-XTM-SERIES-MONITORING/equipmentBoardTempHighExceeded[{#SNMPVALUE}],#1)<>1</p><p>Recovery expression: </p> | high | |
[] Secondary DC Power Failed on {#SNMPVALUE} (LLD) | <p>-</p> | <p>Expression: last(/ZBX-INFINERA-XTM-SERIES-MONITORING/equipmentBoardSecondaryPowerFailed[{#SNMPVALUE}],#1)<>1</p><p>Recovery expression: </p> | high | |
[10.002] CU SFP/II | High Rx Optical Power on {#SNMPVALUE} : {ITEM.VALUE2} (LLD) | <p>-</p> | <p>Expression: last(/ZBX-INFINERA-XTM-SERIES-MONITORING/dcnIfReceivedPowerHigh[{#SNMPVALUE}],#1)<>1 and find(/ZBX-INFINERA-XTM-SERIES-MONITORING/dcnIfDescr[{#SNMPVALUE}],,”like”,”this_does_not_exist”)=0</p><p>Recovery expression: </p> | high |
[10.002] CU SFP/II | Low Rx Optical Power on {#SNMPVALUE} : {ITEM.VALUE2} (LLD) | <p>-</p> | <p>Expression: last(/ZBX-INFINERA-XTM-SERIES-MONITORING/dcnIfReceivedPowerLow[{#SNMPVALUE}],#1)<>1 and find(/ZBX-INFINERA-XTM-SERIES-MONITORING/dcnIfDescr[{#SNMPVALUE}],,”like”,”this_does_not_exist”)=0</p><p>Recovery expression: </p> | warning |
[02.010] High Subrack Temperature $1 (LLD) | <p>-</p> | <p>Expression: last(/ZBX-INFINERA-XTM-SERIES-MONITORING/equipmentSubrackTempHighExceeded[{#SNMPVALUE}],#1)<>1</p><p>Recovery expression: </p> | warning |