Available versions




SNMP OfficeConnect 19XX

Overview

SNMPV2

Works on Office Connect Switches
1910
1920
1950

Low Level Discovery for:

Author

Union College

Macros used

There are no macros links in this template.

There are no template links in this template.

Discovery rules

Name Description Type Key and additional info
Entity Discovery <p>-</p> SNMP agent entity.discovery<p>Update: 3600</p>
Interfaces <p>-</p> SNMP agent interfaces.discovery<p>Update: 3600</p>
PSU Discovery <p>Discovering all entities of PhysicalClass - 6: powerSupply(6)</p> SNMP agent psu.discovery<p>Update: 3600</p>
Fan Discovery <p>Discovering all entities of PhysicalClass - 7: fan(7)</p> SNMP agent fan.discovery<p>Update: 3600</p>
Mac Address <p>-</p> SNMP agent macaddress.discovery<p>Update: 3600</p>
Temperature Discovery <p>Discovering modules temperature (same filter as in Module Discovery) plus and temperature sensors</p> SNMP agent temp.discovery<p>Update: 3600</p>
Memory Useage <p>-</p> SNMP agent memoryusage.discovery<p>Update: 3600</p>
CPU <p>-</p> SNMP agent cpu.discovery<p>Update: 3600</p>

Items collected

Name Description Type Key and additional info
Uptime <p>-</p> SNMP agent Uptime<p>Update: 60</p>
Firmware version <p>-</p> SNMP agent system.hw.firmware[entPhysicalFirmwareRev.{#SNMPINDEX}]<p>Update: 3600</p><p>LLD</p>
Hardware model name <p>-</p> SNMP agent system.hw.model[entPhysicalDescr.{#SNMPINDEX}]<p>Update: 3600</p><p>LLD</p>
Hardware serial number <p>-</p> SNMP agent system.hw.serialnumber[entPhysicalSerialNum.{#SNMPINDEX}]<p>Update: 3600</p><p>LLD</p>
Hardware version(revision) <p>-</p> SNMP agent system.hw.version[entPhysicalHardwareRev.{#SNMPINDEX}]<p>Update: 3600</p><p>LLD</p>
Operating system <p>-</p> SNMP agent system.sw.os[entPhysicalSoftwareRev.{#SNMPINDEX}]<p>Update: 3600</p><p>LLD</p>
In Errors {#SNMPINDEX} <p>-</p> SNMP agent ifInErrors[{#SNMPINDEX}]<p>Update: 30</p><p>LLD</p>
Incoming traffic on interface {#SNMPINDEX} <p>-</p> SNMP agent ifInOctets[{#SNMPVALUE}]<p>Update: 10</p><p>LLD</p>
Status Port {#SNMPINDEX} <p>-</p> SNMP agent ifOperStatus[{#SNMPINDEX}]<p>Update: 60</p><p>LLD</p>
Out Errors {#SNMPINDEX} <p>-</p> SNMP agent ifOutErrors[{#SNMPINDEX}]<p>Update: 30</p><p>LLD</p>
Outgoing traffic on interface {#SNMPINDEX} <p>-</p> SNMP agent ifOutOctets[{#SNMPVALUE}]<p>Update: 10</p><p>LLD</p>
{#ENT_NAME}: Power supply status <p>MIB: HH3C-ENTITY-EXT-MIB Indicate the error state of this entity object. psuError(51) means that the Power Supply Unit is in the state of fault. rpsError(61) means the Redundant Power Supply is in the state of fault.</p> SNMP agent sensor.psu.status[hh3cEntityExtErrorStatus.{#SNMPINDEX}]<p>Update: 60</p><p>LLD</p>
{#ENT_NAME}: Fan status <p>MIB: HH3C-ENTITY-EXT-MIB Indicate the error state of this entity object. fanError(41) means that the fan stops working.</p> SNMP agent sensor.fan.status[hh3cEntityExtErrorStatus.{#SNMPINDEX}]<p>Update: 60</p><p>LLD</p>
Base MAC Address <p>-</p> SNMP agent macaddress[{#SNMPINDEX}]<p>Update: 86400</p><p>LLD</p>
{#MODULE_NAME}: Temperature °C <p>MIB: HH3C-ENTITY-EXT-MIB The temperature for the {#MODULE_NAME}.</p> SNMP agent sensor.temp.value[hh3cEntityExtTemperature.{#SNMPINDEX}]<p>Update: 60</p><p>LLD</p>
{#MODULE_NAME}: Temperature °F <p>MIB: HH3C-ENTITY-EXT-MIB The temperature for the {#MODULE_NAME}.</p> Calculated sensor.tempf.value[hh3cEntityExtTemperature.{#SNMPINDEX}]<p>Update: 60</p><p>LLD</p>
Memory Total <p>-</p> SNMP agent memory.total[{#SNMPINDEX}]<p>Update: 86400</p><p>LLD</p>
Memory Useage <p>-</p> Calculated memoryusage.calc[{#SNMPINDEX}]<p>Update: 60</p><p>LLD</p>
Memory Usage % <p>-</p> SNMP agent memoryusage.perc[{#SNMPINDEX}]<p>Update: 60</p><p>LLD</p>
CPU Percent Utilization <p>-</p> SNMP agent cpu[{#SNMPINDEX}]<p>Update: 30</p><p>LLD</p>

Triggers

Name Description Expression Priority
CPU too high <p>-</p> <p>Expression: {SNMP OfficeConnect 19XX:cpu[{#SNMPINDEX}].last()}>85</p><p>Recovery expression: </p> high
{#ENT_NAME}: Fan is in critical state <p>41 = Fan Error 91 = Hardware Faulty</p> <p>Expression: {SNMP OfficeConnect 19XX:sensor.fan.status[hh3cEntityExtErrorStatus.{#SNMPINDEX}].count(#1,41)}=1 or {SNMP OfficeConnect 19XX:sensor.fan.status[hh3cEntityExtErrorStatus.{#SNMPINDEX}].count(#1,91)}=1</p><p>Recovery expression: </p> high
CRC Errors RX on {#SNMPINDEX} <p>-</p> <p>Expression: {SNMP OfficeConnect 19XX:ifInErrors[{#SNMPINDEX}].last()}>100</p><p>Recovery expression: </p> warning
CRC Errors TX on {#SNMPINDEX} <p>-</p> <p>Expression: {SNMP OfficeConnect 19XX:ifOutErrors[{#SNMPINDEX}].last()}>100</p><p>Recovery expression: </p> warning
Low free memory on {HOST.NAME} <p>-</p> <p>Expression: {SNMP OfficeConnect 19XX:memoryusage.perc[{#SNMPINDEX}].avg(15m)}>80</p><p>Recovery expression: </p> average
{#ENT_NAME}: Power supply is in critical state <p>-</p> <p>Expression: {SNMP OfficeConnect 19XX:sensor.psu.status[hh3cEntityExtErrorStatus.{#SNMPINDEX}].count(#1,51,eq)}=1 or {SNMP OfficeConnect 19XX:sensor.psu.status[hh3cEntityExtErrorStatus.{#SNMPINDEX}].count(#1,61,eq)}=1</p><p>Recovery expression: </p> disaster
{#SNMPVALUE}: Temp to high <p>-</p> <p>Expression: {SNMP OfficeConnect 19XX:sensor.temp.value[hh3cEntityExtTemperature.{#SNMPINDEX}].last()}>50</p><p>Recovery expression: </p> high
CRC Errors RX on {#SNMPINDEX} (LLD) <p>-</p> <p>Expression: {SNMP OfficeConnect 19XX:ifInErrors[{#SNMPINDEX}].last()}>100</p><p>Recovery expression: </p> warning
CRC Errors TX on {#SNMPINDEX} (LLD) <p>-</p> <p>Expression: {SNMP OfficeConnect 19XX:ifOutErrors[{#SNMPINDEX}].last()}>100</p><p>Recovery expression: </p> warning
{#ENT_NAME}: Power supply is in critical state (LLD) <p>-</p> <p>Expression: {SNMP OfficeConnect 19XX:sensor.psu.status[hh3cEntityExtErrorStatus.{#SNMPINDEX}].count(#1,51,eq)}=1 or {SNMP OfficeConnect 19XX:sensor.psu.status[hh3cEntityExtErrorStatus.{#SNMPINDEX}].count(#1,61,eq)}=1</p><p>Recovery expression: </p> disaster
{#ENT_NAME}: Fan is in critical state (LLD) <p>41 = Fan Error 91 = Hardware Faulty</p> <p>Expression: {SNMP OfficeConnect 19XX:sensor.fan.status[hh3cEntityExtErrorStatus.{#SNMPINDEX}].count(#1,41)}=1 or {SNMP OfficeConnect 19XX:sensor.fan.status[hh3cEntityExtErrorStatus.{#SNMPINDEX}].count(#1,91)}=1</p><p>Recovery expression: </p> high
{#SNMPVALUE}: Temp to high (LLD) <p>-</p> <p>Expression: {SNMP OfficeConnect 19XX:sensor.temp.value[hh3cEntityExtTemperature.{#SNMPINDEX}].last()}>50</p><p>Recovery expression: </p> high
Low free memory on {HOST.NAME} (LLD) <p>-</p> <p>Expression: {SNMP OfficeConnect 19XX:memoryusage.perc[{#SNMPINDEX}].avg(15m)}>80</p><p>Recovery expression: </p> average
CPU too high (LLD) <p>-</p> <p>Expression: {SNMP OfficeConnect 19XX:cpu[{#SNMPINDEX}].last()}>85</p><p>Recovery expression: </p> high

SNMP OfficeConnect 19XX

Overview

SNMPV2

Works on Office Connect Switches
1910
1920
1950

Low Level Discovery for:

Author

Union College

Macros used

There are no macros links in this template.

There are no template links in this template.

Discovery rules

Name Description Type Key and additional info
Interfaces <p>-</p> SNMP agent interfaces.discovery<p>Update: 3600</p>
Memory Useage <p>-</p> SNMP agent memoryusage.discovery<p>Update: 3600</p>
Mac Address <p>-</p> SNMP agent macaddress.discovery<p>Update: 3600</p>
Temperature Discovery <p>Discovering modules temperature (same filter as in Module Discovery) plus and temperature sensors</p> SNMP agent temp.discovery<p>Update: 3600</p>
CPU <p>-</p> SNMP agent cpu.discovery<p>Update: 3600</p>
Fan Discovery <p>Discovering all entities of PhysicalClass - 7: fan(7)</p> SNMP agent fan.discovery<p>Update: 3600</p>
Entity Discovery <p>-</p> SNMP agent entity.discovery<p>Update: 3600</p>
PSU Discovery <p>Discovering all entities of PhysicalClass - 6: powerSupply(6)</p> SNMP agent psu.discovery<p>Update: 3600</p>

Items collected

Name Description Type Key and additional info
Uptime <p>-</p> SNMP agent Uptime<p>Update: 60</p>
In Errors {#SNMPINDEX} <p>-</p> SNMP agent ifInErrors[{#SNMPINDEX}]<p>Update: 30</p><p>LLD</p>
Incoming traffic on interface {#SNMPINDEX} <p>-</p> SNMP agent ifInOctets[{#SNMPVALUE}]<p>Update: 10</p><p>LLD</p>
Status Port {#SNMPINDEX} <p>-</p> SNMP agent ifOperStatus[{#SNMPINDEX}]<p>Update: 60</p><p>LLD</p>
Out Errors {#SNMPINDEX} <p>-</p> SNMP agent ifOutErrors[{#SNMPINDEX}]<p>Update: 30</p><p>LLD</p>
Outgoing traffic on interface {#SNMPINDEX} <p>-</p> SNMP agent ifOutOctets[{#SNMPVALUE}]<p>Update: 10</p><p>LLD</p>
Memory Total <p>-</p> SNMP agent memory.total[{#SNMPINDEX}]<p>Update: 86400</p><p>LLD</p>
Memory Useage <p>-</p> Calculated memoryusage.calc[{#SNMPINDEX}]<p>Update: 60</p><p>LLD</p>
Memory Usage % <p>-</p> SNMP agent memoryusage.perc[{#SNMPINDEX}]<p>Update: 60</p><p>LLD</p>
Base MAC Address <p>-</p> SNMP agent macaddress[{#SNMPINDEX}]<p>Update: 86400</p><p>LLD</p>
{#MODULE_NAME}: Temperature °C <p>MIB: HH3C-ENTITY-EXT-MIB The temperature for the {#MODULE_NAME}.</p> SNMP agent sensor.temp.value[hh3cEntityExtTemperature.{#SNMPINDEX}]<p>Update: 60</p><p>LLD</p>
{#MODULE_NAME}: Temperature °F <p>MIB: HH3C-ENTITY-EXT-MIB The temperature for the {#MODULE_NAME}.</p> Calculated sensor.tempf.value[hh3cEntityExtTemperature.{#SNMPINDEX}]<p>Update: 60</p><p>LLD</p>
CPU Percent Utilization <p>-</p> SNMP agent cpu[{#SNMPINDEX}]<p>Update: 30</p><p>LLD</p>
{#ENT_NAME}: Fan status <p>MIB: HH3C-ENTITY-EXT-MIB Indicate the error state of this entity object. fanError(41) means that the fan stops working.</p> SNMP agent sensor.fan.status[hh3cEntityExtErrorStatus.{#SNMPINDEX}]<p>Update: 60</p><p>LLD</p>
Firmware version <p>-</p> SNMP agent system.hw.firmware[entPhysicalFirmwareRev.{#SNMPINDEX}]<p>Update: 3600</p><p>LLD</p>
Hardware model name <p>-</p> SNMP agent system.hw.model[entPhysicalDescr.{#SNMPINDEX}]<p>Update: 3600</p><p>LLD</p>
Hardware serial number <p>-</p> SNMP agent system.hw.serialnumber[entPhysicalSerialNum.{#SNMPINDEX}]<p>Update: 3600</p><p>LLD</p>
Hardware version(revision) <p>-</p> SNMP agent system.hw.version[entPhysicalHardwareRev.{#SNMPINDEX}]<p>Update: 3600</p><p>LLD</p>
Operating system <p>-</p> SNMP agent system.sw.os[entPhysicalSoftwareRev.{#SNMPINDEX}]<p>Update: 3600</p><p>LLD</p>
{#ENT_NAME}: Power supply status <p>MIB: HH3C-ENTITY-EXT-MIB Indicate the error state of this entity object. psuError(51) means that the Power Supply Unit is in the state of fault. rpsError(61) means the Redundant Power Supply is in the state of fault.</p> SNMP agent sensor.psu.status[hh3cEntityExtErrorStatus.{#SNMPINDEX}]<p>Update: 60</p><p>LLD</p>

Triggers

Name Description Expression Priority
CPU too high <p>-</p> <p>Expression: last(/SNMP OfficeConnect 19XX/cpu[{#SNMPINDEX}])>85</p><p>Recovery expression: </p> high
{#ENT_NAME}: Fan is in critical state <p>41 = Fan Error 91 = Hardware Faulty</p> <p>Expression: count(/SNMP OfficeConnect 19XX/sensor.fan.status[hh3cEntityExtErrorStatus.{#SNMPINDEX}],#1,,”41”)=1 or count(/SNMP OfficeConnect 19XX/sensor.fan.status[hh3cEntityExtErrorStatus.{#SNMPINDEX}],#1,,”91”)=1</p><p>Recovery expression: </p> high
CRC Errors RX on {#SNMPINDEX} <p>-</p> <p>Expression: last(/SNMP OfficeConnect 19XX/ifInErrors[{#SNMPINDEX}])>100</p><p>Recovery expression: </p> warning
CRC Errors TX on {#SNMPINDEX} <p>-</p> <p>Expression: last(/SNMP OfficeConnect 19XX/ifOutErrors[{#SNMPINDEX}])>100</p><p>Recovery expression: </p> warning
Low free memory on {HOST.NAME} <p>-</p> <p>Expression: avg(/SNMP OfficeConnect 19XX/memoryusage.perc[{#SNMPINDEX}],15m)>80</p><p>Recovery expression: </p> average
{#ENT_NAME}: Power supply is in critical state <p>-</p> <p>Expression: count(/SNMP OfficeConnect 19XX/sensor.psu.status[hh3cEntityExtErrorStatus.{#SNMPINDEX}],#1,”eq”,”51”)=1 or count(/SNMP OfficeConnect 19XX/sensor.psu.status[hh3cEntityExtErrorStatus.{#SNMPINDEX}],#1,”eq”,”61”)=1</p><p>Recovery expression: </p> disaster
{#SNMPVALUE}: Temp to high <p>-</p> <p>Expression: last(/SNMP OfficeConnect 19XX/sensor.temp.value[hh3cEntityExtTemperature.{#SNMPINDEX}])>50</p><p>Recovery expression: </p> high
CRC Errors RX on {#SNMPINDEX} (LLD) <p>-</p> <p>Expression: last(/SNMP OfficeConnect 19XX/ifInErrors[{#SNMPINDEX}])>100</p><p>Recovery expression: </p> warning
CRC Errors TX on {#SNMPINDEX} (LLD) <p>-</p> <p>Expression: last(/SNMP OfficeConnect 19XX/ifOutErrors[{#SNMPINDEX}])>100</p><p>Recovery expression: </p> warning
Low free memory on {HOST.NAME} (LLD) <p>-</p> <p>Expression: avg(/SNMP OfficeConnect 19XX/memoryusage.perc[{#SNMPINDEX}],15m)>80</p><p>Recovery expression: </p> average
{#SNMPVALUE}: Temp to high (LLD) <p>-</p> <p>Expression: last(/SNMP OfficeConnect 19XX/sensor.temp.value[hh3cEntityExtTemperature.{#SNMPINDEX}])>50</p><p>Recovery expression: </p> high
CPU too high (LLD) <p>-</p> <p>Expression: last(/SNMP OfficeConnect 19XX/cpu[{#SNMPINDEX}])>85</p><p>Recovery expression: </p> high
{#ENT_NAME}: Fan is in critical state (LLD) <p>41 = Fan Error 91 = Hardware Faulty</p> <p>Expression: count(/SNMP OfficeConnect 19XX/sensor.fan.status[hh3cEntityExtErrorStatus.{#SNMPINDEX}],#1,,”41”)=1 or count(/SNMP OfficeConnect 19XX/sensor.fan.status[hh3cEntityExtErrorStatus.{#SNMPINDEX}],#1,,”91”)=1</p><p>Recovery expression: </p> high
{#ENT_NAME}: Power supply is in critical state (LLD) <p>-</p> <p>Expression: count(/SNMP OfficeConnect 19XX/sensor.psu.status[hh3cEntityExtErrorStatus.{#SNMPINDEX}],#1,”eq”,”51”)=1 or count(/SNMP OfficeConnect 19XX/sensor.psu.status[hh3cEntityExtErrorStatus.{#SNMPINDEX}],#1,”eq”,”61”)=1</p><p>Recovery expression: </p> disaster

SNMP OfficeConnect 19XX

Overview

SNMPV2

Works on Office Connect Switches
1910
1920
1950

Low Level Discovery for:

Author

Union College

Macros used

There are no macros links in this template.

There are no template links in this template.

Discovery rules

Name Description Type Key and additional info
Interfaces <p>-</p> SNMP agent interfaces.discovery<p>Update: 3600</p>
Memory Useage <p>-</p> SNMP agent memoryusage.discovery<p>Update: 3600</p>
Mac Address <p>-</p> SNMP agent macaddress.discovery<p>Update: 3600</p>
Temperature Discovery <p>Discovering modules temperature (same filter as in Module Discovery) plus and temperature sensors</p> SNMP agent temp.discovery<p>Update: 3600</p>
CPU <p>-</p> SNMP agent cpu.discovery<p>Update: 3600</p>
Fan Discovery <p>Discovering all entities of PhysicalClass - 7: fan(7)</p> SNMP agent fan.discovery<p>Update: 3600</p>
Entity Discovery <p>-</p> SNMP agent entity.discovery<p>Update: 3600</p>
PSU Discovery <p>Discovering all entities of PhysicalClass - 6: powerSupply(6)</p> SNMP agent psu.discovery<p>Update: 3600</p>

Items collected

Name Description Type Key and additional info
Uptime <p>-</p> SNMP agent Uptime<p>Update: 60</p>
In Errors {#SNMPINDEX} <p>-</p> SNMP agent ifInErrors[{#SNMPINDEX}]<p>Update: 30</p><p>LLD</p>
Incoming traffic on interface {#SNMPINDEX} <p>-</p> SNMP agent ifInOctets[{#SNMPVALUE}]<p>Update: 10</p><p>LLD</p>
Status Port {#SNMPINDEX} <p>-</p> SNMP agent ifOperStatus[{#SNMPINDEX}]<p>Update: 60</p><p>LLD</p>
Out Errors {#SNMPINDEX} <p>-</p> SNMP agent ifOutErrors[{#SNMPINDEX}]<p>Update: 30</p><p>LLD</p>
Outgoing traffic on interface {#SNMPINDEX} <p>-</p> SNMP agent ifOutOctets[{#SNMPVALUE}]<p>Update: 10</p><p>LLD</p>
Memory Total <p>-</p> SNMP agent memory.total[{#SNMPINDEX}]<p>Update: 86400</p><p>LLD</p>
Memory Useage <p>-</p> Calculated memoryusage.calc[{#SNMPINDEX}]<p>Update: 60</p><p>LLD</p>
Memory Usage % <p>-</p> SNMP agent memoryusage.perc[{#SNMPINDEX}]<p>Update: 60</p><p>LLD</p>
Base MAC Address <p>-</p> SNMP agent macaddress[{#SNMPINDEX}]<p>Update: 86400</p><p>LLD</p>
{#MODULE_NAME}: Temperature °C <p>MIB: HH3C-ENTITY-EXT-MIB The temperature for the {#MODULE_NAME}.</p> SNMP agent sensor.temp.value[hh3cEntityExtTemperature.{#SNMPINDEX}]<p>Update: 60</p><p>LLD</p>
{#MODULE_NAME}: Temperature °F <p>MIB: HH3C-ENTITY-EXT-MIB The temperature for the {#MODULE_NAME}.</p> Calculated sensor.tempf.value[hh3cEntityExtTemperature.{#SNMPINDEX}]<p>Update: 60</p><p>LLD</p>
CPU Percent Utilization <p>-</p> SNMP agent cpu[{#SNMPINDEX}]<p>Update: 30</p><p>LLD</p>
{#ENT_NAME}: Fan status <p>MIB: HH3C-ENTITY-EXT-MIB Indicate the error state of this entity object. fanError(41) means that the fan stops working.</p> SNMP agent sensor.fan.status[hh3cEntityExtErrorStatus.{#SNMPINDEX}]<p>Update: 60</p><p>LLD</p>
Firmware version <p>-</p> SNMP agent system.hw.firmware[entPhysicalFirmwareRev.{#SNMPINDEX}]<p>Update: 3600</p><p>LLD</p>
Hardware model name <p>-</p> SNMP agent system.hw.model[entPhysicalDescr.{#SNMPINDEX}]<p>Update: 3600</p><p>LLD</p>
Hardware serial number <p>-</p> SNMP agent system.hw.serialnumber[entPhysicalSerialNum.{#SNMPINDEX}]<p>Update: 3600</p><p>LLD</p>
Hardware version(revision) <p>-</p> SNMP agent system.hw.version[entPhysicalHardwareRev.{#SNMPINDEX}]<p>Update: 3600</p><p>LLD</p>
Operating system <p>-</p> SNMP agent system.sw.os[entPhysicalSoftwareRev.{#SNMPINDEX}]<p>Update: 3600</p><p>LLD</p>
{#ENT_NAME}: Power supply status <p>MIB: HH3C-ENTITY-EXT-MIB Indicate the error state of this entity object. psuError(51) means that the Power Supply Unit is in the state of fault. rpsError(61) means the Redundant Power Supply is in the state of fault.</p> SNMP agent sensor.psu.status[hh3cEntityExtErrorStatus.{#SNMPINDEX}]<p>Update: 60</p><p>LLD</p>

Triggers

Name Description Expression Priority
CPU too high <p>-</p> <p>Expression: last(/SNMP OfficeConnect 19XX/cpu[{#SNMPINDEX}])>85</p><p>Recovery expression: </p> high
{#ENT_NAME}: Fan is in critical state <p>41 = Fan Error 91 = Hardware Faulty</p> <p>Expression: count(/SNMP OfficeConnect 19XX/sensor.fan.status[hh3cEntityExtErrorStatus.{#SNMPINDEX}],#1,,”41”)=1 or count(/SNMP OfficeConnect 19XX/sensor.fan.status[hh3cEntityExtErrorStatus.{#SNMPINDEX}],#1,,”91”)=1</p><p>Recovery expression: </p> high
CRC Errors RX on {#SNMPINDEX} <p>-</p> <p>Expression: last(/SNMP OfficeConnect 19XX/ifInErrors[{#SNMPINDEX}])>100</p><p>Recovery expression: </p> warning
CRC Errors TX on {#SNMPINDEX} <p>-</p> <p>Expression: last(/SNMP OfficeConnect 19XX/ifOutErrors[{#SNMPINDEX}])>100</p><p>Recovery expression: </p> warning
Low free memory on {HOST.NAME} <p>-</p> <p>Expression: avg(/SNMP OfficeConnect 19XX/memoryusage.perc[{#SNMPINDEX}],15m)>80</p><p>Recovery expression: </p> average
{#ENT_NAME}: Power supply is in critical state <p>-</p> <p>Expression: count(/SNMP OfficeConnect 19XX/sensor.psu.status[hh3cEntityExtErrorStatus.{#SNMPINDEX}],#1,”eq”,”51”)=1 or count(/SNMP OfficeConnect 19XX/sensor.psu.status[hh3cEntityExtErrorStatus.{#SNMPINDEX}],#1,”eq”,”61”)=1</p><p>Recovery expression: </p> disaster
{#SNMPVALUE}: Temp to high <p>-</p> <p>Expression: last(/SNMP OfficeConnect 19XX/sensor.temp.value[hh3cEntityExtTemperature.{#SNMPINDEX}])>50</p><p>Recovery expression: </p> high
CRC Errors RX on {#SNMPINDEX} (LLD) <p>-</p> <p>Expression: last(/SNMP OfficeConnect 19XX/ifInErrors[{#SNMPINDEX}])>100</p><p>Recovery expression: </p> warning
CRC Errors TX on {#SNMPINDEX} (LLD) <p>-</p> <p>Expression: last(/SNMP OfficeConnect 19XX/ifOutErrors[{#SNMPINDEX}])>100</p><p>Recovery expression: </p> warning
Low free memory on {HOST.NAME} (LLD) <p>-</p> <p>Expression: avg(/SNMP OfficeConnect 19XX/memoryusage.perc[{#SNMPINDEX}],15m)>80</p><p>Recovery expression: </p> average
{#SNMPVALUE}: Temp to high (LLD) <p>-</p> <p>Expression: last(/SNMP OfficeConnect 19XX/sensor.temp.value[hh3cEntityExtTemperature.{#SNMPINDEX}])>50</p><p>Recovery expression: </p> high
CPU too high (LLD) <p>-</p> <p>Expression: last(/SNMP OfficeConnect 19XX/cpu[{#SNMPINDEX}])>85</p><p>Recovery expression: </p> high
{#ENT_NAME}: Fan is in critical state (LLD) <p>41 = Fan Error 91 = Hardware Faulty</p> <p>Expression: count(/SNMP OfficeConnect 19XX/sensor.fan.status[hh3cEntityExtErrorStatus.{#SNMPINDEX}],#1,,”41”)=1 or count(/SNMP OfficeConnect 19XX/sensor.fan.status[hh3cEntityExtErrorStatus.{#SNMPINDEX}],#1,,”91”)=1</p><p>Recovery expression: </p> high
{#ENT_NAME}: Power supply is in critical state (LLD) <p>-</p> <p>Expression: count(/SNMP OfficeConnect 19XX/sensor.psu.status[hh3cEntityExtErrorStatus.{#SNMPINDEX}],#1,”eq”,”51”)=1 or count(/SNMP OfficeConnect 19XX/sensor.psu.status[hh3cEntityExtErrorStatus.{#SNMPINDEX}],#1,”eq”,”61”)=1</p><p>Recovery expression: </p> disaster