Tags: ups

Based on numerous APC's templates (tnx folks!) and lots of digging in PowerNet-MIB. General items and triggers. Items for all three phases. Some power (W/VAC) items disabled for cosmetic reasons, but still functional - feel free to reuse 'em. Created by ...

Category:APC
Type
Min Zabbix version2.2.x

Based on https://share.zabbix.com/power-ups/eaton/eaton-powerware-9355 -  Алексей A. Translated all Russian language and units to English.  Also provided all Value Mappings in importable XML format. Value Mappings were exported from Zabbix 3.0. May work ...

Category:Eaton Powerware
Type
Min Zabbix version2.0.x

Zabbix APC Template dedicated for not-Windows APC PowerChute Business Edition installations which don't provide SNMP feature.Especially for using VMA based installation (under vmWare ESXi). Monitoring following items: Last update Internal Temperatur ...

Category:APC
Type
Min Zabbix version2.2.x

Based on XUPS::MIB from Eaton Powerware. (XUPS-MIB.txt)  Tested on Eaton Powerware BladeUPS  Monitors: xupsEnvRemoteHumidity   xupsEnvRemoteTemp               xupsEnvAmbientHumidity          xupsBatTimeRemaining  *  xupsEnvRemoteTempUpperLimit     ...

Category:Eaton Powerware
Type
Min Zabbix version2.4.x

Template for Switching Power Distribution Unit with environmental sensor. Includes triggers for: Self Test Status Power source changed power source shortcircuit Power souirce status source 1 and 2 Humidity high Temperature high As this unit is ...

Category:Eaton Powerware
Type
Min Zabbix version3.2.x

Zabbix template apcupsd Tested on Zabbix Version 3.2 FEATURES Model Driver Remaining battery percentage Remaining runtime in minutes Status Connection Timeout REQUIREMENTS Zabbix server version 3.2 &

Category:APC
Type
Min Zabbix version3.2.x

Basic SNMP template and value maps for monitoring Eaton 5PX series UPS. This template includes several items, triggers and graphs.

Category:Eaton
Type
Min Zabbix version3.2.x

Tensão e voltagem de entrada e saída. Informações de temperatura e carga da bateria.

Category:Emerson NP
Type
Min Zabbix version2.2.x

Category:Ippon
Type
Min Zabbix version2.2.x

Athough I've seen some Emerson templates, none of them worked with my UPS GXT3-XXXXX. So I created this template with lld for the UPS outputs and some itens that I usually need (like % Load). It's basic but can help someone in need some day. Battery Cha ...

Category:Emerson NP
Type
Min Zabbix version3.4.x

This template was originaly created for the AP9619 card, but in version 2 now support more UPS's.Tested on: APC Symmetra PX40 3Phase UPSAPC Smart-UPS VT 20kVA 3Phase UPSSmart-UPS RT 7500 RM XLand more... It gathers input and output values from all three ...

Category:APC
Type
Min Zabbix version2.2.x

This template is for situation when you have apcupsd, but cannot install zabbix agent. Tested with Centos 6.x. You have to install apcupsd and configure it, configure ssh access for user by certificate. Provides: Items: model, serial number, number of ...

Category:APC
Type
Min Zabbix version3.4.x

SNMP Template for UPS Eaton Model SC200, tested with Zabbix 3.0 (should work in older versions) Battery Status Input AC Output DC

Category:Eaton
Type
Min Zabbix version3.0.x

SNMP Template for REILLLO UPS, tested with Zabbix 3.4 (should work in older versions) Battery Status, Input/output load, Alarms.  This template requires Reillo MIB files (RFC1628A.MIB ) to be import into Zabbix server. 

Category:Others
Type
Min Zabbix version3.4.x

Features Monitoring: input and output voltage, battery voltage and temperature, load Requirements Windows 7 or higherWindows server 2008 R2 or higher

Category:Ippon
Type
Min Zabbix version3.4.x

Шаблон для подключения платы сетевого управления в составе однофазных ИБП российского производителя ЭНТЕЛ. Шаблон включает в себя 3 группы элементов данных, 12 элементов данных, 10 триггеров и 4 графика и позволяет наблюдать за основными метриками. Груп ...

Category:Entel
Type
Min Zabbix version3.0.x

This is a very simple template to monitoring APC Smart-UPS RT 8000XL. Using this template you can monitor:- snmp connection- internal temperature (if the sensor is available)- battery status- last self-test- when it go on battery This template it is tes ...

Category:APC
Type
Min Zabbix version3.4.x

Hi guys,this is a very simple template to monitor an UPS that use NIC NetAgent to manage it using network connection. This simple template can check the status of the battery, when it use battery and other simple information about energy. I have persona ...

Category:Others
Type
Min Zabbix version3.4.x

This is Zabbix 3.0+ template for Tripplite UPS with option card WEBCARDLX. Includes 23 items, 1 applications, 15 triggers, 3 Graphs Monitors power parameters like voltage and frequency, battery charge and status, battery temperature, etc. Has triggers f ...

Category:Tripplite
Type
Min Zabbix version3.0.x

Portuguese items description, graphs names and application, but SNMP keys in English. Input, output, load, battery, external probe, UPS state.

Category:Eaton
Type
Min Zabbix version3.0.x