Power (UPS)

An uninterruptible power supply, also uninterruptible power source, UPS or battery/flywheel backup, is an electrical apparatus that provides emergency power to a load when the input power source, typically mains power, fails. A UPS differs from an auxiliary or emergency power system or standby generator in that it will provide near-instantaneous protection from input power interruptions, by supplying energy stored in batteries, supercapacitors, or flywheels. The on-battery runtime of most uninterruptible power sources is relatively short (only a few minutes) but sufficient to start a standby power source or properly shut down the protected equipment.

Add new listing Add Category

★★★★½

★★★★½

Russian language На основе проекта network-ups-tools-nut. Добавлено: поддержка нескольких значений для поля ups.status поддержка нескольких значений для поля ups.alarm обработка ошибки "Error: Variable not supported by UPS" Список параметров: ...

Type
Min Zabbix version3.0.x

Template made based on Phillip Hernandez template: https://share.zabbix.com/power-ups/apc/apc-ups All OID's were changed to match general MIB for UPS. New graphs were also added. 21 Items 9 Triggers 7 Graphs I also have a template made for three-pha ...

Type
Min Zabbix version4.0.x

Popular

★★★★★

Popular

★★★★★

Monitor power parametrs: frequency, power, voltage, current, temp. Full control for Input, Output (Segment), Battery, Bypass. I used CPQPOWER1.76.MIB and UPS-MIB.mib

Type
Min Zabbix version4.0.x

Description This package has been done to monitor UPSes which have been configured with NUT package. Yes, you read it, this package is able to monitor several UPSes by using LLD rules. This way, you can track UPS status, power loss, battery charge and ...

Type
Min Zabbix version4.2.x

NUT monitoring template with items description, graphs, triggers. For many UPS support working through NUT, example for Ippon.

Min Zabbix version2.0.x

Zabbix template for COVER UPS No MIBs required! tested with model PMR 6kV, should work with other models too (and probably with more chinease made UPS that partialy use RFC-1628) only basic items, some triggers and graphs added as well. Created i ...

Type
Min Zabbix version3.0.x

A change made of template made by Rubens Urquisa e Josué Campelo  All nobreaks SMS with Net Adapter II, Input voltage information, frequency, temperature, battery charge.  Triggers activate Work with Mono and Tri voltages (Tested with Sinus Double Blac ...

Type
Min Zabbix version3.0.x

Updated! Fixed an incorrect OID and refined one of the graphs. This template was made from scratch for a SU20KRT8 (Using the newest Tripplite MIBs. Zabbix devs, come on and write MIB ingestion into the GUI already.). However, it should support any type o ...

Type
Min Zabbix version3.2.x

Simple SNMPv1 template for Delta UPS with LLD for lines.Tested on Zabbix 3.0 but should works on older versions. Required extra configuration: Macro for UPS-MIB

Type
Min Zabbix version2.2.x

Template for Online USV - XANTO S1500R tested with xabbix 3.2 via SNMP   Monitoring and triggers for - Current Battery load in % - Battery capacity - remaining runtime in min - temperature - Voltage Input / Output - MAC, USV Model, system runtime ...

Type
Min Zabbix version3.0.x

Content: - 8 Items- 9 Triggers- 2 Graphs   Made for the HP R5000 but should work on most HP Power supplys. If it works for your UPS please hit me up so I can Include it in the Description.

Type
Min Zabbix version2.2.x

Apresentando o template para o dispositivo VOLT Full Power 380 1U Gerenciável Para utilizar o template em seu Zabbix, siga os passos abaixo: 1. Instale o MIB da Volt em seu servidor Zabbix, ele pode ser obtido acessando a interface web do dispositivo. S ...

Type
Min Zabbix version3.4.x