Categories
SGI (5)

Zabbix template & scripts to discover & monitor Linux sensors Features: Low-level discovery of sensors: temperature (with thresholds), fans and power Triggers on temperature & fans (detect stopped fan, adjustable) Usage: Put sensors ...

Category:Server Hardware
Type
Min Zabbix version2.4.x

SNMP monitoring of HP servers which have HP SNMP Agents installed (i.e. DL360 & BL360 series). [Health, Drives 0&1, Drive Array, Memory, Inventory], Triggers [Health, Drives, Drive Array, Fans, Memory, Thermal]

Category:HP
Min Zabbix version2.0.x

Hello! It's my fist template. Warning! FAN3, FAN4, FAN6, FAN7, FAN8 disabled for me.

Category:Supermicro
Type
Min Zabbix version3.0.x

IBM server status of System State, Discovery Temperature sensor (with trigger), Discovery Fan sensor and speed, Discovery Voltage via SNMP and IMM/IMM2. Copy getFanSpeed.rb to "externalscripts" on Zabbix server, and install Ruby. Read README.TXT before u ...

Category:IBM and Lenovo
Min Zabbix version2.0.x

IBM server status of HDD, memory banks and power supplies via SNMP and IBM Director Agent. Tested on IBM System x3650/x3550/x3550m2/x3550m3, eServer Series 345/346. Read README.TXT before using. Only for Zabbix 2.2.x or higher!

Category:IBM and Lenovo
Min Zabbix version2.2.x

Based on https://share.zabbix.com/cat-server-hardware/cisco/cisco-ucs-standalone-hw-monitoring Contains: MB operation state rack serial number Discoveries: Arrays CPUs Disks Fans Memory PSU Raid batterys Raid controllers

Category:Cisco
Type
Min Zabbix version4.2.x

Supermicro A+ 2042G server

Category:Other
Min Zabbix version2.0.x

IPMI sensors for SGI Altix C2108-G9 : +1.1 V, +1.8 V, +3.3 V, +3.3VSB, +5 V, +12 V, CPU1 DIMM, CPU1 DIMM VTT, CPU1 Temp, CPU1 Vcore, CPU2 DIMM, CPU2 DIMM VTT, CPU2 Temp, CPU2 Vcore, FAN 1, FAN 2, FAN 3, HT Voltage, Power, System Temp, VBAT   27/09/2016 ...

Category:SGI
Type
Min Zabbix version2.4.x

IPMI sensors for SGI Altix C2112-4G10: +1.1 V, +1.8 V, +3.3 V, +3.3VSB, +5 V, +12 V, CPU1 DIMM, CPU1 DIMM VTT, CPU1 Temp, CPU1 Vcore, CPU2 DIMM, CPU2 DIMM VTT, CPU2 Temp, CPU2 Vcore, FAN 1, FAN 2, HT Voltage, Power, System Temp, VBAT   27/09/2016: Som ...

Category:SGI
Type
Min Zabbix version2.4.x

IPMI sensors for SGI Altix H2106-G7: +3.3V, +3.3VSB, +5V, +12V, CPU1 DIMM, CPU1 Temp, CPU1 Vcore, CPU2 DIMM, CPU2 Temp, CPU2 Vcore, CPU3 DIMM, CPU3 Temp, CPU3 Vcore, CPU4 DIMM, CPU4 Temp, CPU4 Vcore, Fan1, Fan2, Fan3, Fan4, Fan5, Fan6, Power, System Temp ...

Category:SGI
Type
Min Zabbix version2.4.x

IPMI sensors for SGI Altix C2112-GP2 IPMI: 1.05V PCH, 1.2V BMC, 1.5V PCH, 3.3VCC, 3.3VSB, 5VCC, 5VSB, 12V, CPU1 Temp, CPU2 Temp, FAN1, FAN2, FAN7, FAN8, P1-DIMMA1 Temp, P1-DIMMA2 Temp, P1-DIMMB1 Temp, P1-DIMMB2 Temp, P1-DIMMC1 Temp, P1-DIMMC2 Temp, P1-DI ...

Category:SGI
Type
Min Zabbix version3.0.x

IPMI sensors for SGI Altix ISS3114: Agg Therm Mgn 1, BB +1.05Vccp P1, BB +1.05Vccp P2, BB +1.1V STBY, BB +1.5 P1MEM AB, BB +1.5 P1MEM CD, BB +1.5 P2MEM AB, BB +1.5 P2MEM CD, BB +1.8V AUX, BB +3.3V, BB +3.3V AUX, BB +3.3V Vbat, BB +5.0V, BB +5.0V STBY, BB ...

Category:SGI
Type
Min Zabbix version2.4.x

IPMI HW status [Health, Fan, Power, Temperature, Voltage], Triggers [Temperature, Power, Fans, Voltage]

Category:Other
Min Zabbix version2.0.x

IPMI HW status [Health, Fan, Power, Temperature, Voltage], Triggers [Temperature, Power, Fans, Voltage]

Category:Other
Min Zabbix version2.0.x

IPMI HW status [Health, Drives, Fan, Power, Temperature], Triggers [Health, Memory]

Category:Other
Min Zabbix version2.0.x

Template for Disk IO data gathering on Zabbix via SNMP

Category:Other
Type
Min Zabbix version2.4.x

Template parse prtdiag on Sun blade 2000 server command and get: ASIC status CPU status FAN status PCI cards status Temperature status   First install supported agent on Operating system (try older versions)

Category:Other
Type
Min Zabbix version4.2.x

Template parse prtdiag on Sun enterprise T2000 server command and get: CPU status HDD status Fan status MB sensors status PSU status Temperature status 

Category:Other
Type
Min Zabbix version4.2.x

Simple template to monitor Sun v440 server To use it install zabbix agent on v440 server and copy conf file to use userparameter settings. This template contains: CPU status HDD status Fan status MB sensors status PCI status PSU status Temperatur ...

Category:Other
Type
Min Zabbix version4.2.x

Simple template to monitor Sun v890server To use it install zabbix agent on v890 server and copy conf file to use userparameter settings. This template contains: CPU status HDD status Fan status MB sensors status

Category:Other
Type
Min Zabbix version4.2.x