Categories

Simple IPMI template fetching:   * Read Chassis Temperature* Read System Voltage* Read Fan speeds* Read Power (Voltage/Watts)

Category:Dell
Type
Min Zabbix version3.4.x

Dell idrac Popular

Based on https://github.com/endersonmaia/zabbix-templates/tree/master/dell/idrac and https://share.zabbix.com/cat-server-hardware/dell/dell-idrac-chinese. Chinese version translated back to english.       

Category:Dell
Type
Min Zabbix version3.0.x

IPMI HW status [Health, Drives, Fan, Power, Temperature, Temperature Memory], Triggers [Health, Drives, Temperature, Power, Fans]

Category:HP
Min Zabbix version2.0.x

IPMI readout for Dell PowerEdge M610 blades.   Reading Power usage and temperature.  

Category:Server Hardware
Type
Min Zabbix version3.4.x

IPMI HW status [Health, Fan, Power, Temperature], Triggers [Temperature, Power, Fans]

Category:HP
Min Zabbix version2.0.x

IPMI HW status [Health, Drives, Fan, Power, Temperature, Temperature Memory], Triggers [Health, Drives, Temperature, Power, Fans]

Category:HP
Min Zabbix version2.0.x

IPMI HW status [Health, Fan, Power, Temperature], Triggers [Temperature, Power, Fans]

Category:HP
Type
Min Zabbix version2.0.x

Adapted from the official DL380p Gen8 template by Aleksej Pustovalov.    Items: All 66 IPMI keys for HP DL360p Gen8 servers.  Triggers: Memory, Fan, Disk errors and CPU temperature, plus Sys. Health LED Graph: CPU temperature   Instructions for use: ...

Category:HP
Type
Min Zabbix version3.0.x

IPMI sensors for Dell PowerEdge 1950: Ambient Temp, FAN MOD 1A RPM, FAN MOD 1B RPM, FAN MOD 1C RPM, FAN MOD 1D RPM, FAN MOD 2A RPM, FAN MOD 2B RPM, FAN MOD 2C RPM, FAN MOD 2D RPM, FAN MOD 3A RPM, FAN MOD 3B RPM, FAN MOD 3C RPM, FAN MOD 3D RPM, FAN MOD 4A ...

Category:Dell
Type
Min Zabbix version2.4.x

IPMI sensors for Dell PowerEdge 2900: Ambient Temp, FAN 1 RPM, FAN 2 RPM, FAN 3 RPM, FAN 4 RPM, FAN 5 RPM, FAN 6 RPM, Power   27/09/2016: Some changes and fixes.

Category:Dell
Type
Min Zabbix version2.4.x

IPMI sensors for Dell PowerEdge T300: Ambient Temp, FAN 1 RPM, FAN 2 RPM, Planar Temp, Power   27/09/2016: Some changes and fixes.

Category:Dell
Type
Min Zabbix version2.4.x

IPMI sensors for Dell PowerEdge T320: Current 1, Current 2, Inlet Temp, Power, Pwr Consumption, Sys Fan1 RPM, Temp, Voltage 1, Voltage 2   27/09/2016: Some changes and fixes.

Category:Dell
Type
Min Zabbix version2.4.x

这是https://share.zabbix.com/network_devices/cat-dell-sonicwall/dell-idrac的中文化版本,同时进行了修正以支持zabbix3.0,感谢原作者

Category:Dell
Type
Min Zabbix version3.0.x

IPMI sensors for Dell PowerEdge T420: Current 1, Current 2, Inlet Temp, Power, Pwr Consumption, Sys Fan1 RPM, Temp, Voltage 1, Voltage 2   27/09/2016: Some changes and fixes.

Category:Dell
Type
Min Zabbix version2.4.x

IPMI sensors for Dell PowerEdge T620: Current 1, Current 2, Fan1 RPM, Fan2 RPM, Inlet Temp, Power, Pwr Consumption, Voltage 1, Voltage 2, Temp   27/09/2016: Some changes and fixes. Add Temp Sensor.

Category:Dell
Type
Min Zabbix version2.4.x

Simple IPMI template fetching:   * Read Chassis Temperature* Read System Voltage* Read Fan speeds* Read Power (Voltage/Watts)

Category:Dell
Type
Min Zabbix version3.4.x

Simple template for Dell T310 IPMI monitoring. Contains: 4 sensors (Fan, Temp, Power state and consumption) 8 triggers (Fan speed too slow, Temp too high, Power down, Power consumption too high) 2 graphics (Fan speed + Temp, Power consumption) Is ...

Category:Dell
Type
Min Zabbix version3.4.x

iDRAC RedFish monitoring framework  With this you can use the feature from iDRAC called redfish, which is a RESTful API. He will (LLD) auto discover most of the important hardware components via iDRAC / redfish and add them to your monitoring.  Built i ...

Category:Dell
Type
Min Zabbix version4.0.x