share.zabbix.com will be closed soon as integrations have been migrated to GitHub. Please use GitHub repository for all your community template needs.

Server Hardware: All Listings 

Filter listings...

IPMI sensors for SGI Altix ISS3114: Agg Therm Mgn 1, BB +1.05Vccp P1, BB +1.05Vccp P2, BB +1.1V STBY, BB +1.5 P1MEM AB, BB +1.5 P1MEM CD, BB +1.5 P2MEM AB, BB +1.5 P2MEM CD, BB +1.8V AUX, BB +3.3V, BB +3.3V AUX, BB +3.3V Vbat, BB +5.0V, BB +5.0V STBY, BB ...

Category:SGI
Type
Min Zabbix version2.4.x

Intel® Remote Management Module 3 Sensors: 1  | BB +1.05V PCH    | Voltage 2  | BB +1.1V P1 Vccp | Voltage                 3  | BB +1.5V P1 DDR3 | Voltage               4  | BB +3.3V         | Voltage                  5  | BB +3.3V STBY    | Vo ...

Category:Intel
Type
Min Zabbix version3.0.x

IPMI HW status [Fan, Temperature, Voltage], Triggers [Fan, Temperature, Voltage], Graphs [Fan, Temperature, Voltage, Watts]

Category:Intel
Type
Min Zabbix version3.0.x

There is template for monitoring (QuickSync)integrated video in Intel processors: You can monitor theese parameters: Multi-Format Codec Engine (also known as “MFX” or “VDBOX”); Video Encode (PAK) and Decode 2nd instance of the MultiFormat Codec Engine, ...

Category:Intel
Type
Min Zabbix version4.4.x

Category:Intel
Type
Min Zabbix version4.4.x

Features: LLD for fans LLD for disk drives LLD for logical disks LLD for PSU  Tested on: Cisco UCS C220 M3 Cisco UCS C220 M4

Category:Cisco
Type
Min Zabbix version3.0.x

Monitoring Cisco UCS Server for snmp v2 Working with B and C Blade server tested on Cisco chassis 5018 and B200M4 . it give you this info : Servers Hardware component info. Temperature monitoring . FAN monitoring . PSU monitoring . Memory monitor ...

Category:Cisco
Type
Min Zabbix version4.0.x

Template for monitoring IPMI sensors for Cisco UCS servers hardware tested on C220M3 please disable absend HDD and unsupported items after some time. sensors and triggers: cpu temperature DDR modules status HDD status LED fan status overal leds ...

Category:Cisco
Type
Min Zabbix version4.2.x

Based on https://share.zabbix.com/cat-server-hardware/cisco/cisco-ucs-standalone-hw-monitoring Contains: MB operation state rack serial number Discoveries: Arrays CPUs Disks Fans Memory PSU Raid batterys Raid controllers

Category:Cisco
Type
Min Zabbix version4.2.x

CISCO-EIGRP-MIBitems in the template:total number of existing EIGRP derived routes cEigrpTopoRoutes.0 total number query reply packets sent cEigrpRepliesSent.0 format of the router-id type cEigrpAsRouterIdType.0 total number of Stuck-In-Active (SIA) qu ...

Category:Cisco
Type
Min Zabbix version5.2.x

思科UCS交换矩阵监控模板  包括CPU、Raid卡、内存、刀片、电源、硬盘、风扇、端口状态 将宏替换为实际团体字即可 某些情况下监控是浮动地址无效,需要监控实际地址

Category:Cisco
Type
Min Zabbix version4.0.x

通过SNMP监控华为iBMC和华为iMana接口,已经在华为RH2288v2、RH2288v3  RH2485上验证。监控整体健康、型号、序列号等信息。同时可以自动发现内存、风扇、硬盘、温度数据。适用于zabbix 3.x 更新: 2019.05.11,请下载Huawei_iBMC_v5.zip的附件。 最新模板V5,实测支持最新华为服务器 H2288V5 主机,新增了一些告警,其中低级发现更新周期为1d,添加主机后需要1天才能发现内存硬盘风扇等相信信息。或者手动修改发现周期 先导入valuema ...

Category:Huawei
Type
Min Zabbix version3.0.x

This template for RH5885H V3 Protocol SNMP v2 Items 177 with low discovery   Triggers:   System health status critical System health status status major System health status status minor   CPU status critical CPU status major CPU status minor ...

Category:Huawei
Type
Min Zabbix version4.2.x

After a Huawei CCU template is imported and SNMPv3 community name of CCU is configured in the template, you can view following information: Latest data tab page: system software version, system hardware version, module name, MAC address, photoelectric li ...

Category:Huawei
Type
Min Zabbix version4.4.x

After a Huawei Chassis SWI template is imported and SNMPv2c or SNMPv3 community name of CCU is configured in the template, you can view following information: Monitoring page: l   Latest data tab page: alarm serial number, sensor name, event description ...

Category:Huawei
Type
Min Zabbix version3.4.x

After a Huawei Chassis EMM template is imported and SNMPv3 community name of CCU is configured in the template, you can view following information: Monitoring page: l   Latest data tab page: alarm serial number, sensor name, event description, alarm sev ...

Category:Huawei
Type
Min Zabbix version3.4.x

After a Huawei Server HMM template is imported and SNMPv2c community name of HMM is configured in the template, you can view following information: Monitoring page: l   Latest data tab page: CPU, fan, power supply, switch, system information, and temper ...

Category:Huawei
Type
Min Zabbix version3.4.x

After a Huawei Server iBMC template is imported and SNMPv2c community name of IBMC is configured in the template, you can view following information: Monitoring page: l   Latest data tab page: CPU, fan, hard disk, iBMC system information, memory, power ...

Category:Huawei
Type
Min Zabbix version3.4.x

Necessário configuração na vlan.   vlan <vlanid>  description <nome vlan>  statistic enable

Category:Huawei
Type
Min Zabbix version4.2.x

This is my first template file for Huawei Fusion Module 800 datacenter. Depending on your Fusion Module configuration some more devices may be added. Protocol SNMPv2 Discovery for Door Claps Lock Cooling devices Power Module Smart ETH TH Sensors ...

Category:Huawei
Type
Min Zabbix version5.4.x